• 제목/요약/키워드: Drug-eluting Stent

검색결과 42건 처리시간 0.03초

The assessment of the performance of drug-eluting stent using computational fluid dynamics

  • Seo, Tae-Won;Barakat, Abdul I.
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.281-288
    • /
    • 2009
  • Numerical investigations have been conducted on the assessment of the performance of drug-eluting stent. Computational fluid dynamics is applied to investigate the flow disturbances and drug distributions released from the stent in the immediate vicinity of the given idealized stent in the protrusion into the flow domain. Our simulations have revealed the drug concentration in the flow field due to the presence of a drug-eluting stent within an arterial segment. Wall shear stress increases with Reynolds number for a given stent diameter, while it increases with stent diameter for a given Reynolds number. The drug concentration is dependent on both Reynolds number and stent geometry. In pulsatile flow, the minimum drug concentration in the zone of inter-wire spacing occurs at the maximum acceleration of the inlet flow while the maximum drug concentration gains at the maximum deceleration of the inlet flow. These results provide an understanding of the flow physics in the vicinity of drug-eluting stents and suggest strategies for optimal performance of drug-eluting stent to minimize flow disturbance.

고리형 약물분출 스텐트 주위 벽전단응력의 영향에 대한 수치해석 (Numerical Analysis on the Effect of Wall Shear Stress Around the Ring Drug-Eluting Stent)

  • 서태원
    • 대한기계학회논문집B
    • /
    • 제31권1호
    • /
    • pp.21-28
    • /
    • 2007
  • The use of drug-eluting stents has dramatically reduced the incidence of restenosis however, much remains to be teamed about the performance of these stouts. In the present study, we tested the hypothesis that the design of drug-eluting stents influences the efficacy of local drug delivery to the arterial wall and that this effect depends on both arterial geometry and the prevailing flow conditions. We performed computational simulations in which the coupled Navier-Stokes and advection-diffusion equations were solved to determine the flow field and drug concentration in the vicinity of model drug-eluting stouts It is found that the characteristics of flow phenomena can be influenced greatly by the ratio of stent diameter to vessel diameter. The presence of drug-eluting stent may have profound effect on wall shear stresses, recirculation sizes and drug distributions. The results show that recirculation zone is influenced by the imposed flow conditions and stent diameter. In pulsatile flow, the low wall shear stress and high drug concentration occur along the arterial wall during the decelerating flow conditions. These results could provide the guideline for future drug-eluting stent designs toward reducing restenosis by affecting local wall shear stress distributions associated with neointimal hyperplasia.

약물방출스텐트의 약물 방출 특성 평가 방법 개발 (Development of Evaluation Method for Drug Release Propreties in Drug Eluting Stent)

  • 송정민;백홍;이승영;장동혁;서무엽;박길종;맹은호
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.69-72
    • /
    • 2013
  • The goal of this study is to develop test method for evaluating the drug eluting properties of drug eluting stents (DES). PBS and the detergent solutions, presented by each DES manufacturer, were used for drug release of DES coated with paclitaxel, zotarolimus and everolimus. The drugs which are coating DES were not released by PBS but released by the detergent solutions, finally paclitaxel 83.38%, zotarolimus 103.85% and everolimus 115.78%. It seems that the use of the detergents is necessary in order to release the drugs because those drugs are extremely hydrophobic. In conclusion, using of detergent solutions presented by each manufacturer were suitable for evaluating the drug eluting property of drug eluting stent.

약물분출 스텐트 주위 유동형태와 약물침전에 대한 수치해석 (Numerical Study of Flow Pattern and Drug Deposition in Drug-Eluting Stent)

  • 서태원
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1053-1060
    • /
    • 2011
  • 본 연구는 이상적인 원형 환(Ideal Circular Ring) 스텐트와 Intertwined 스텐트의 삽입에 의해 야기 되는 혈류유동 형태와 스텐트 표면에서 방출되는 약물의 농도분포를 조사하는 것이다. 본 연구를 통해 Intertwined 스텐트의 스텐트 사이 영역에서 약물농도는 원형 환 스텐트에 비해 더 많이 분포해 있는 것을 알 수 있었다. 주어진 스텐트의 형상에 대하여 스텐트 사이 영역에서의 국소적인 약물 농도분포는 레이놀즈 수가 증가함에 따라 감소하는 것으로 나타났다. 주어진 레이놀즈 수에 대하여는 약물 농도분포는 스텐트의 형상과는 비교적 무관함을 알 수 있다. 원형 환 스텐트보다 Intertwined스텐트가 스텐트사이 영역과 스텐트 하류영역에서혈관 벽면을 따른 약물 농도분포는 크게 나타나는 것을 볼 수 있다.

관상동맥 약물 용출 스텐트 삽입 후 항혈소판제제 3제요법과 2제요법의 임상적 효과 비교 (Effect of Triple Compared to Dual Antiplatelet Therapy After Drug-Eluting Stent Implantation in Percutaneous Coronary Intervention)

  • 예경남;김정태;이숙향
    • 한국임상약학회지
    • /
    • 제22권2호
    • /
    • pp.113-122
    • /
    • 2012
  • ACC/AHA/SCAI Guideline recommends for administration dual antiplatelet therapy after drug-eluting stent (DES) to prevent restenosis and stent thrombosis in patients with percutaneous coronary intervention (PCI). Recently triple antiplatelet therapy including cilostazol is known to reduce restenosis and stent thrombosis significantly after DES implantation. However, there is lack of data providing the efficacy of triple antiplatelet therapy. The purpose of this study is to evaluate the clinical effects of the triple therapy after DES implantation compared with the dual therapy. This retrospective study collected data from medical charts of 251 patients who received DES implantation between Jul 2006 and Jun 2008. They received either dual antiplatelet therapy (N = 154 clopidogrel and aspirin; Dual group) or triple antiplatelet therapy (N = 97 cliostazol, clopidogrel and aspirin; Triple group). Major adverse cardiac event rates (MACE, included total death, myocardial infarction, target lesion revascularization) at 12 months, 24 months, stent thrombosis, rates of bleeding complications and adverse drug reactions were compared between these two groups. Compared with the dual group, the triple group had a similar incidence of the MACE rates at 24months (12.3% vs. 12.4%, p = 0.99). There is no difference in overall stent thrombosis between two groups (Dual group 2.6% vs. Triple group 4.1%, p = 0.5). Subgroup analysis showed that diabetic patients got more benefit in reducing MACE rates but, there is no statistical difference. Bleeding complications and adverse drug effects were not different significantly. As compared with dual antiplatelet therapy, triple antiplatelet therapy did not reduce the 12-months, 24-months MACE rates and stent thrombosis. Bleeding complications and adverse drug effects were not different.

Coating defects in polymer-coated drug-eluting stents

  • Bedair, Tarek M.;Cho, Youngjin;Park, Bang Ju;Joung, Yoon Ki;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권3호
    • /
    • pp.131-150
    • /
    • 2014
  • Vascular stenting has a great attention as a treatment for coronary arteries diseases as compared with percutaneous balloon angioplasty. In-stent restenosis and thrombosis are side effects resulting from using bare metal stent (BMS). Employing platelet therapy allowed to reduce the rate of thrombosis, however, the rate of restenosis remains a major problem. In 2002, drug-eluting stents (DESs) were introduced as an effort to reduce the restenosis. The commercially available DESs continue to suffer from coating defects that might lead to a series of adverse effects. Most importantly, multiple concerns remain regarding the polymer coating integrity on metal surfaces or the relation of polymer irregularities to longterm adverse events.

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권1호
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

약물-용출 생분해성 고분자 스텐트를 위한 EGCG와 디자인 파라미터의 영향에 대한 연구 (A Study on Effects of EGCG and Design Parameter for Drug-Eluting Biodegradable Polymer Stents)

  • 정태곤;이종호;이준재;현승휴;한동욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.111-116
    • /
    • 2013
  • Finite element analysis(FEA) has been extensively applied in the analyses of biomechanical properties of stents. Geometrically, a closed-cell stent is an assembly of a number of repeated unit cells and exhibits periodicity in both longitudinal and circumferential directions. This study concentrates on various parameters of the FEA models for the analysis of drug-eluting biodegradable polymeric stents for application to the treatment of coronary artery disease. In order to determine the mechanical characteristics of biodegradable polymeric stents, FEA was used to model two different types of stents: tubular stents(TS) and helicoidal stents(HS). For this modeling, epigallocatechin-3-O-gallate (EGCG)-eluting poly[(L-lactide-co-${\varepsilon}$-caprolactone), PLCL] (E-PLCL) was chosen as drug-eluting stent materials. E-PLCL was prepared by blending PLCL with 5% EGCG as previously described. In addition, the effects of EGCG blending on the mechanical properties of PLCL were investigated for both types of stent models. EGCG did not affect tensile strength at break, but significantly increased elastic modulus of PLCL. It is suggested that FEA is a cost-effective method to improve the design of drug-eluting biodegradable polymeric stents.

효율적인 약물 방출 스텐트 제조를 위한 고분자 코팅물질 개발 (Development of Polymeric Coating Material for Effective Drug-eluting Stent)

  • 박태현;조은애;나건
    • 폴리머
    • /
    • 제35권5호
    • /
    • pp.483-487
    • /
    • 2011
  • 효율적 비혈관용 약물방출 스텐트 제조를 위해 풀루란 아세테이트(pullulan acetate, PA)가 테프론(poly-tetrafluorethylene; PTFE)으로 피막된 스텐트(PTFE-stent)의 코팅재료로 연구되었다. 파크리탁셀 함유 PA가 코팅된 PTFE-stent의 표면, 약물 방출 거동, 세포독성이 측정되었으며, 동물실험을 통해 이의 가능성이 검토되었다. 전자현미경으로 표면을 관찰한 결과 표면이 PTFE 피막에 비해 훨씬 매끄러웠고, 약물은 80일 동안 서방적 방출 거동을 보였다. PA와 함께 코팅된 파크리탁셀의 안정성을 annexin V 결합 염색법을 통하여 측정한 결과 apoptosis의 비율이 천연 파크리탁셀과 유사한 것으로 보아 봉입된 파크리탁셀의 변성이 없음을 알 수 있었다. 소동물 실험에서는 파크리탁셀이 봉입된 PA-PTFE가 고형암의 성장을 억제하였다. 위의 결과로 보아 PA는 효율적 비혈관계 약물방출 스텐트 개발에 매우 유용한 물질이라고 기대된다.