• Title/Summary/Keyword: Drop-out

Search Result 1,045, Processing Time 0.031 seconds

Achieving Relative Loss Differentiation using D-VQSDDP with Differential Drop Probability (차별적이니 드랍-확률을 갖는 동적-VQSDDP를 이용한 상대적 손실차별화의 달성)

  • Kyung-Rae Cho;Ja-Whan Koo;Jin-Wook Chung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.1332-1335
    • /
    • 2008
  • In order to various service types of real time and non-real time traffic with varying requirements are transmitted over the IEEE 802.16 standard is expected to provide quality of service(QoS) researchers have explored to provide a queue management scheme with differentiated loss guarantees for the future Internet. The sides of a packet drop rate, an each class to differential drop probability on achieving a low delay and high traffic intensity. Improved a queue management scheme to be enhanced to offer a drop probability is desired necessarily. This paper considers multiple random early detection with differential drop probability which is a slightly modified version of the Multiple-RED(Random Early Detection) model, to get the performance of the best suited, we analyzes its main control parameters (maxth, minth, maxp) for achieving the proportional loss differentiation (PLD) model, and gives their setting guidance from the analytic approach. we propose Dynamic-multiple queue management scheme based on differential drop probability, called Dynamic-VQSDDP(Variable Queue State Differential Drop Probability)T, is proposed to overcome M-RED's shortcoming as well as supports static maxp parameter setting values for relative and each class proportional loss differentiation. M-RED is static according to the situation of the network traffic, Network environment is very dynamic situation. Therefore maxp parameter values needs to modify too to the constantly and dynamic. The verification of the guidance is shown with figuring out loss probability using a proposed algorithm under dynamic offered load and is also selection problem of optimal values of parameters for high traffic intensity and show that Dynamic-VQSDDP has the better performance in terms of packet drop rate. We also demonstrated using an ns-2 network simulation.

3D Flow Analysis of Globe Valve with Air Operated Actuator (공기구동형 글로브 밸브의 3차원 유동 해석)

  • Chung, M. H.;Yang, S. M.;Lee, H. Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.7-13
    • /
    • 2005
  • Although the globe is the most typical valve to control high pressure drop in piping system, it is very hard to figure out the characteristics of flow field in the globe valve caused by its complex geometry, So there is very few studies to find out flow characteristics of globe valve. In this study numerical analysis for flow field in the globe valve is carried out using the FLUENT code which is commercial CFD program. Pressure drop through the globe valve is also measured to verify the results come from numerical analysis. Comparing experiment with numerical analysis, two results are very close to each other.

A Study Comparison and Analysis of Electrical Characteristics of IGBTs with Variety Gate Structures (다양한 게이트 구조에 따른 IGBT 소자의 전기적 특성 비교 분석 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.681-684
    • /
    • 2016
  • This research was carried out experiments of variety IGBTs for industrial inverter and electric vehicle. The devices for this paper were planar gate IGBT, trench gate IGBT and dual gate IGBT and we designed using same design and process parameters. As a result of experiments, the electrical characteristics of planar gate IGBT were 1,459 V of breakdown voltage, 4.04 V of threshold voltage and 4.7 V of on-state voltage drop. And the electrical characteristics of trench gate IGBT were 1,473 V of breakdown voltage, 4.11 V of threshold voltage and 3.17 V of on-state voltage drop. Lastly, the electrical characteristics of dual gate IGBT were 1,467 V of breakdown voltage, 4.14 V of threshold voltage and 3.08V of on-state voltage drop. We almost knew that the trench gate IGBT was superior to dual gate IGBT in terms of breakdown voltage. On the other hand, the dual gate IGBT was better than the trench gate IGBT in terms of on state voltage drop.

The Thermal and Flow Analysis in the Channel of Plate Heat Exchanger with Crossed-Discrete Ribs (직교하는 단락형 리브를 부착한 판형 열교환기 관내측 열유동 해석)

  • Lee, Kwan-Soo;Moon, Hyoung-Kyu;Chung, Kilyoan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.678-686
    • /
    • 1999
  • The purpose of this work is to Investigate the pressure drop and the heat transfer characteristics in the channel of plate heat exchanger with crossed-discrete ribs. The flow is assumed to be three-dimensional, laminar and periodically fully developed. Computations have been carried out for angles of attack from $0^{\circ}$ to $90^{\circ}$ and ratios of rib height from 0.15 to 0.46 for various values of Reynolds and Prandtl numbers. The heat transfer was improved by inclined ribs generating helical vortices and secondary flows. The results show that the pressure drop has a maximum value at $70^{\circ}$ and the heat transfer has a maximum value at $45^{\circ}$. As the rib height increases, the pressure drop and the heat transfer increase quadratically, and the increasing rate of pressure drop is higher than that of the heat transfer. As Reynolds number increases, the pressure drop increases in proportion to the square of Reynolds number and the heat transfer increases linearly.

A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type (볼트체결방식의 IP-2형 운반용기의 낙하예비시험)

  • Kim Dong-Hak;Seo Ki-seog;Park Hong Yun;Lee Kyung Ho;Yoon Jeong-Hyoun;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.339-347
    • /
    • 2005
  • A type IP-2 transport package should prevent a loss or dispersal of the radioactive contents and a more than $20\%$ increase in the maximum radiation level at any external surface of the package when it were subjected to the drop test under the normal conditions of transport. If a shielding thickness of IP-2 transport package is thick, a bolted lid type may prevent a loss or dispersal of the radioactive contents than the door type of ISO containers which are generally used as a type IP-2 transport package. In this paper, to evaluate the effect of drop directions on the bolt tension and the coherence of a bolt, the drop tests of preliminary small model are tested and evaluated for seven directions before the drop test of a type IP-2 transport package with a bolted lid type under the normal conditions of transport. Seven drop directions which are a bottom-vertical drop, a lid-vortical drop. a horizontal drop and four corner drops have been carried out. Using a force sensor, the bolt tension during the drop impact is measured. The coherence of bolt is evaluated by the difference between the fastening torque of bolt before a drop test and the unfastening torque of bolt after a drop impact.

  • PDF

Characteristics of Somatotype Classified by the Drop Value of Middle-Aged Women (중년 여성의 드롭치에 따른 체형 특성 연구)

  • Yoon, Ji-Won;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.6
    • /
    • pp.939-946
    • /
    • 2009
  • This study is to classify the shape of the body by means of the drop value of the middle-age women. Drop value is based on the circumstances of the body deciding the dimentions of the clothes. Therefore, the study based on the drop value seems to decided the measurement of the clothes in making mass production of ready made clothes. In order to put measure items on this study of the value on 'The fifth survey of body measure of Korean', select 785 people in middle-aged women aged from 40 to 59. And considering the characteristic of upper-drop and lower-drop, and swelling belly by accumulated fat, selected five items(Bust Circumstance - Waist Circumstance, Hip Circumstance - Waist Circumstance, Hip Circumstance - Bust Circumstance, Waist Circumstance(Omphalion) - Waist Circumstance, Hip Circumstance - Waist Circumstance(Omphalion)). The result of the study is summarized as follows. Type 1, M type of the body showed the distribution of 32.5% and belonged to low body development style. The line of human body is the nearest of the four bodies in middle-age woman out of whole shapes of 4 types and the line of human body is close to middle-age woman. Type 2, X type of the body showed the distribution of 40.8% and the line of human body remarkably showed. Type 3, H type of the body showed the distribution of 12.4% and the line of human body appears least. This group was larger than any other group in having more fat in the belly above the circumstance of the hip than other groups. Type 4, Y type of the body showed the distribution of 14.4%. This type was upper half of body development style, waist was slender, and there was seldom the bend around the circumstance of belly and hip.

  • PDF

The Analytic and Numerical Solutions of the 1$\frac{1}{2}$-layer and 2$\frac{1}{2}$-layer Models to the Strong Offshore Winds.

  • Lee, Hyong-Sun
    • Journal of the korean society of oceanography
    • /
    • v.31 no.2
    • /
    • pp.75-88
    • /
    • 1996
  • The analytic and numerical solution of the 1$\frac{1}{2}$-layer and 2$\frac{1}{2}$-layer models are derived. The large coastal-sea level drop and the fast westward speed of the anticyclonic gyre due to strong offshore winds using two ocean models are investigated. The models are forced by wind stress fields similar in structure to the intense mountain-pass jets(${\sim}$20 dyne/$cm^{2}$) that appear in the Gulfs of Tehuantepec and Papagayo in the Central America for periods of 3${\sim}$7 days. Analytic and numerical solutions compare favorably with observations, the large sea-level drop (${\sim}$30 cm) at the coast and the fast westward propagation speeds (${\sim}$13 km/day) of the gyres. The coastal sea-level drop is enhanced by several factors: horizontal mixing, enhanced forcing, coastal geometry, and the existence of a second active layer in the 2$\frac{1}{2}$-layer model. Horizontal mixing enhances the sea-level drop because the coastal boundary layer is actually narrower with mixing. The forcing ${\tau}$/h is enhanced near the coast where h is thin. Especially, in analytic solutions to the 2$\frac{1}{2}$-layer model the presence of two baroclinic modes increases the sea-level drop to some degree. Of theses factors the strengthened forcing ${\tau}$/h has the largest effect on the magnitude of the drop, and when all of them are included the resulting maximum drop is -30.0 cm, close to observed values. To investigate the processes that influence the propagation speeds of anticyclonic gyre, several test wind-forced calculations were carried out. Solutions to dynamically simpler versions of the 1$\frac{1}{2}$-layer model show that the speed is increased both by ${\beta}$-induced self-advection and by larger h at the center ofthe gyres. Solutions to the 2$\frac{1}{2}$-layer model indicate that the lower-layer flow field advects the gyre westward and southward, significantly increasing their propagation speed. The Papagayo gyre propagates westward at a speed of 12.8 km/day, close to observed speeds.

  • PDF

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

Centrifuge modeling of dynamically penetrating anchors in sand and clay

  • An, Xiaoyu;Wang, Fei;Liang, Chao;Liu, Run
    • Geomechanics and Engineering
    • /
    • v.30 no.6
    • /
    • pp.539-549
    • /
    • 2022
  • Accidental anchor drop can cause disturbances to seabed materials and pose significant threats to the safety and serviceability of submarine structures such as pipelines. In this study, a series of anchor drop tests was carried out to investigate the penetration mechanism of a Hall anchor in sand and clay. A special anchor drop apparatus was designed to model the inflight drop of a Hall anchor. Results indicate that Coriolis acceleration was the primary cause of large horizontal offsets in sand, and earth gravity had negligible impact on the lateral movement of dropped anchors. The indued final horizontal offset was shown to increase with the elevated drop height of an anchor, and the existence of water can slow down the landing velocity of an anchor. It is also observed that water conditions had a significant effect on the influence zone caused by anchors. The vertical influence depth was over 5 m, and the influence radius was more than 3 m if the anchor had a drop height of 25 m in dry sand. In comparison, the vertical influence depth and radius reduced to less than 3 m and 2 m, respectively, when the anchor was released from 10 m height and fell into the seabed with a water depth of 15 m. It is also found that the dynamically penetrating anchors could significantly influence the earth pressure in clay. There is a non-linear increase in the measured penetration depth with kinematic energy, and the resulted maximum earth pressure increased dramatically with an increase in kinematic energy. Results from centrifuge model tests in this study provide useful insights into the penetration mechanism of a dropped anchor, which provides valuable data for design and planning of future submarine structures.

Design of a Pin-Fin Structure in a Channel Considering the Heat Transfer and Pressure Drop Characteristics (열전달 및 압력강하 특성을 고려한 채널 내 핀-휜 구조물의 설계)

  • Shin, Jee-Young;Son, Young-Seok;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.459-467
    • /
    • 2006
  • Rapid development of electronic technology requires small size, high density packaging and high power in the electronic devices, which results in more heat generation. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the current state-of-the-art electronic equipment. The aim of the present study is to find out the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices through the analysis and experiment. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. Experimental results are compared with the analyses and correlations of several researchers. Finally, the design guide are provided for the required pressure drop and/or the heat transfer characteristics of the heat exchanger.