• Title/Summary/Keyword: Drop-in test

Search Result 1,190, Processing Time 0.032 seconds

Factors Affecting Adherence to Pharmacotherapy in Children with Attention-Deficit Hyperactivity Disorder: A Retrospective Study (주의력결핍 과잉행동장애 아동의 약물치료 순응도에 영향을 미치는 요인 : 후향적 연구)

  • Kim, Yoon-Jung;Oh, So-Young;Lee, Ji-Ah;Moon, Su-Jin;Lee, Won-Hae;Bahn, Geon-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.21 no.3
    • /
    • pp.174-181
    • /
    • 2010
  • Objectives: To identify the factors affecting long-term adherence to methylphenidate treatment in children with attention-deficit hyperactivity disorder (ADHD). Methods: A retrospective medical record review of 239 ADHD patients (mean age $9.3{\pm}2.6$ years, range 6.0-17.4 years) who had visited the child and adolescent psychiatry clinic at a university hospital, in Seoul, Korea from March 2005 to February 2008. Subjects were diagnosed as ADHD based on the criteria set forth in the Diagnostic and Statistical Manual of Mental Disorders 4th edition, text revision version (DSM-IV-TR) and underwent neuropsychological tests including the continuous performance test (CPT). Treatment discontinuation was defined as the last prescription date when the medication possession rate (MPR) became less than 0.80. Subjects were divided into three groups and labeled as Group I, non-adherence without pharmacotherapy, Group II, non-adherence with short-term pharmacotherapy, and Group III, adherence with long-term pharmacotherapy. Results: Ninety (37.7%) patients were grouped as non-adherent (Groups I+II) and 149 (62.3%) as adherent (Group III). The adherence group exhibited lower intelligence, higher symptom severity, and a higher number of comorbid psychiatric disorders than controls. The use of stimulants was significantly associated with long-term adherence to treatment. Additionally, the duration of interval between the date of the first visit and the date of the first prescription was positively associated with long-term adherence. Conclusion: About two-thirds of patients diagnosed as ADHD adhered to the treatment six months after the first visit. With respect to patient evaluation and the development of treatment strategies, factors affecting early drop-out and longer follow-up must be considered.

A Study on Thermal Performance of Plate Cooler for Cooling Medium Speed Engine Lubricant Oil (선박용 중속엔진 오일냉각용 판형쿨러의 전열성능에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • Plate heat exchangers(PHE) have been commercialized since the 1920s. Since then, although the basic concept of PHEs has changed little, its design and construction have progressed significantly to accommodate higher temperatures, higher pressures, and large heat exchanging capacities. The development trend of PHEs is consistent with heat plate developments with better thermal efficiency, lower pressure drop, and good flow distribution. The purpose of this paper is to introduce the main development processes of a plate cooler for medium-speed engine lubricant oil cooling in vessels which is in line with the development trend of PHEs and to provide its thermal performance data that were found out during experimental tests. The plate cooler in this study cannot measure the wall temperatures directly due to its structural characteristics, so the heat transfer coefficients were calculated using the modified Wilson Plot method. The water-to-water tests were first conducted experimentally to figure out the characteristics of heat transfer coefficients and pressure drops on the water side and then the water-to-oil tests followed to obtain the heat transfer coefficients on the oil side. The test results showed that heat transfer coefficients and pressure drops on both water and oil side increased with flow rates, and it was also found that all the development targets of the plate cooler in this study were achieved successfully.

Flow behavior characteristics according to superficial gas velocity of NiO/MoO3/MoS2 (NiO/MoO3/MoS2의 공탑속도에 따른 유동화 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Lee, Kwan-Young;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • This study identified the loss of minimum fluidization velocity and pressure in accordance with the superficial velocity of $NiO/MoO_3/MoS_2$, a rare metallic oxide and high value-added material in the lab-scale fluidized bed reactor (L=0.25 m, D=0.05 m). The average pressure loss in L/D 1, 2, and 3 of $NiO/MoO_3/MoS_2$ within the scope of superficial gas velocity between 0.07 and 0.45 m/s based on the L/D 1, 2, and 3 of the specimen was shown to be 290~1952 Pa at decreasing flux and 253~1925 Pa at increasing flux. The comparison between the theoretical value proposed by Wen and the test data showed a difference between 0.021~0.36 magnification. Based on these results, this study was able to determine the operation conditions where rare metallic oxides could be applied in real phenomena.

Measurement of Rainfall Intensity Using a Weighting Tipping Bucket Raingauge (중량식 전도형 우량계를 이용한 강우강도 측정)

  • Kim Hyun Chul;Lee Bu Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.4
    • /
    • pp.211-217
    • /
    • 2004
  • The instrument used in this study consists of a lkg capacity loadcell and a Imm tipping bucket rain gauge. There are two signals: one is the weight of the water in the tipping bucket and the other is the pulse from the reversing mechanism of the tipping bucket. The loadcell measures the weight of water with a 0.0lmm resolution up to 1mm rainfall and the bucket reverses beyond 1mm. From this point, a pulse signal generates and the loadcell starts measuring the weight again. A field test was carried out with the range of rainfall intensity from 42mm/h to 250mm/h. The result shows an error range from -2.2% to + 2.6% in 12 measurement cases with a rainfall of l00mm or more. This result satisfies the WMO recommendation for rainfall intensity instrumentation which allows a 5% range. In a field experiment during 17 to 19 August, 2004, more than 100mm/h rainfall intensity was observed by this instrument, confirming that our instrument has a sufficient capacity of rainfall intensity measurement under extreme conditions like Jangma (Bai-u season). Compared with existing commercial models which employ a water drop measurement method, our method can give a practical solution for diagnostic check of remote rain gauges using two independent signals.

Analysis of a Gas Mask Using CFD Simulation (CFD모사기법을 이용한 가스 여과기 성능 해석)

  • Jeon, Rakyoung;Kwon, Kihyun;Yoon, Soonmin;Park, Myungkyu;Lee, Changha;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.475-483
    • /
    • 2019
  • Special chemical warfare agents are lethal gases that attack the human respiratory system. One of such gases are blood agents that react with the irons present in the electron transfer system of the human body. This reaction stops internal respiration and eventually causes death. The molecular sizes of these agents are smaller than the pores of an activated carbon, making chemical adsorption the only alternative method for removing them. In this study, we carried out a Computational Fluid Dynamics simulation by passing a blood agent: cyanogen chloride gas through an SG-1 gas mask canister developed by SG Safety Corporation. The adsorption bed consisted of a Silver-Zinc-Molybdenum-Triethylenediamine activated carbon impregnated with copper, silver, zinc and molybdenum ions. The kinetic analysis of the chemical adsorption was performed in accordance with the test procedure for the gas mask canister and was validated by the kinetic data obtained from experimental results. We predicted the dynamic behaviors of the main variables such as the pressure drop inside the canister and the amount of gas adsorbed by chemisorption. By using a granular packed bed instead of the Ergun equation that is used to model porous materials in Computational Fluid Dynamics, applicable results of the activated carbon were obtained. Dynamic simulations and flow analyses of the chemical adsorption with varying gas flow rates were also executed.

A Comparison Review of Domestic and Imported Cosmetics on Quality Test in Korea Market (위수탁 검사의뢰 국산 및 수입화장품의 비교고찰)

  • Hwang, Young Sook;Choi, Chae Man;Chung, Sam Ju;Park, Ae Sook;Kim, Hyun Jung;Kim, Jung Hun;Jung, Kwon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • This study is aimed to provide the primary data about safety of cosmetics products using indirect preference of korean cosmetics customer and numerical comparison of applied area. For this study, we collected 9,879 cosmetics products which were inspected in cosmetics research team from January, 2010 to December, 2012. The domestic cosmetics was 645 cases (6.5%) and Imported cosmetics was 9,234 cases (93.5%). As manufacturing country, the France has 4,342 cases (44.0%) and the next ranking were like those, Germany 1,637 cases (16.6%), U.S.A 1,476 cases (14.9%), Republic of Korea 645 cases (6.5%), Italy 557 cases (5.6%), and etc 1,222 cases (12.4%). By the year, the cases of test cosmetics have decreased from 3,784 cases (2010), 3,394 cases (2011) to 2,701 cases (2012), the relative ratio of common cosmetics part was drop in but the other group (functional cosmetics and hair dye related products) was increased. The largest market share product was Skin care 5,470 cases (55.4%) and the next order was like those, Make up 1,908 cases (19.3%), Hand & Foot 1,026 cases (10.4%), Hair Care 616 cases (6.2%), Bath 361 cases (3.7%), and etc 498 cases (5.0%). In domestic cosmetics, the greatest proportion was Skin care and the others were Hair Care > Makeup > Hand & Foot > Bath, but the proportion was evidently changed in imported cosmetics, Skin care > Makeup > Hand & Foot > Hair Care > Bath. It is necessary to set the priority of the international quality standards to identify trends from domestic consumers directly or indirectly. Compare the ratio of category and human application parts from domestic and imported cosmetics, we utilize leverage as the basis for future-oriented cosmetic safety.

Bending Impact Properties Evaluation of Sn-xAg-Cu Lead Free Solder Composition and aging treatment (시효처리한 Sn-xAg-Cu계 무연솔더 조성에 따른 굽힘충격 특성평가)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.49-55
    • /
    • 2011
  • The failure of electronic instruments is mostly caused by heat and shock. This shock causes the crack initiation at the solder joint interface of PCB component which is closely related with the formation of intermetallic compound(IMC). The Ag content in Pb-free Sn-xAg-0.5Cu solder alloy used in this study was 1.0, 1.2 and 3.0 wt.%, respectively. After soldering with PCB component, isothermal aging was performed to 1000 hrs. The growth of IMC layer was observed during isothermal aging. The drop impact property of solder joint was evaluated by impact bending test method. The solder joint made with the solder containing lower Ag content showed better impact bending property compared with that with higher Ag content. On the contrary to this result, the solder joint made with solder containing higher Ag content showed better impact bending property after aging. It should be caused by the formation of fine $Ag_3Sn$, which relieved the impact. It showed consequently the different effect of fine $Ag_3Sn$ and coarse $Cu_6Sn_5$ particles formed in the IMC layer on the impact bending property.

Electrical and Fluidic Characterization of Microelectrofluidic Bench Fabricated Using UV-curable Polymer (UV경화성 폴리머를 이용한 미소유체 통합접속 벤치 개발 및 전기/유체적 특성평가)

  • Youn, Se-Chan;Jin, Young-Hyun;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.475-479
    • /
    • 2012
  • We present a novel polymer fabrication process involving direct UV patterning of a hyperbranched polymer, AEO3000. Compared to PDMS, which is the most widely used polymer in bioMEMS devices, the present polymer has advantages with regard to electrode integration and fast fabrication. We designed a four-chip microelectrofluidic bench having three electrical pads and two fluidic I/O ports. We integrated a microfluidic mixer and a cell separator on the bench to characterize the interconnection performance and sample manipulation. Electrical and fluidic characterization of the microfluidic bench was performed. The measured electrical contact resistance was $0.75{\pm}0.44{\Omega}$, which is small enough for electrical applications, and the pressure drop was 8.3 kPa, which was 39.3% of the value in the tubing method. By performing yeast mixing and a separation test in the integrated module on the bench, we successfully showed that the interconnected chips could be used for bio-sample manipulation.

Effects of Visual Feedback Treadmill Gait Training Program Combined with Virtual Reality Technology and a Force Plate Measurement System on Gait Ability and Quality of Life in Stroke Patients (가상현실과 힘판을 통한 시각적 되먹임 트레드밀 보행훈련이 뇌졸중 환자의 보행능력과 삶의 질에 미치는 영향)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.3
    • /
    • pp.363-373
    • /
    • 2020
  • The purpose of this study was to improve the gait ability and quality of life of stroke patients by combining virtual reality technology and a visual feedback gait training program with entertainment elements. Ten stroke patients with circumduction gait were selected. The visual feedback treadmill gait training program using virtual reality technology and a force plate measurement system was conducted 30 minutes a day, 5 days a week, with 25 sessions in 5 weeks. To investigate the effects of this gait training program, evaluations using the joint range-of-motion test, muscle activity tests, Berg balance scale (BBS), gait analysis, and stroke-specific quality-of-life scale (SS-QOL) were performed before and after intervention. Statistically significant differences were found in the joint range of motion and muscle activity of the affected side from the initial swing phase to the mid-swing phase of the gait cycle, dynamic balance, gait function, and quality of life (p <0.05). The results of this study indicate that the gait training program improved the foot drop, muscle activity, dynamic balance, and gait ability of stroke patients with circumduction gait, thereby improving the quality of life of the patients. Therefore, we recommend the application of the visual feedback treadmill gait training program using virtual reality technology and a force plate measurement system to improve gait ability and quality of life of stroke patients with circumduction gait.

The Development of Scales on Rating College Students' Adaptability and the Analysis of Technical Quality (대학적응력 검사도구 척도 개발과 양호도 검증)

  • Kim, Soo-Yoen
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.295-303
    • /
    • 2016
  • The purposes of this study are to describe the process for the instrument construction and the development of scales on rating college students' adaptability and to analyze the technical qualities of the test. The primary goal of this study is to inform students and institutions what is needed to college student's adjustment process into university and college life. The scales are tested by specialty group and statistical methods, and finally composed of 142 items, which measures 8 scales, the academic integration, the social integration into college, career identity, emotional stability, learning condition's stability, relationship with professors, satisfaction degree of educational service, satisfaction degree of college education. This study analyzed 1,959 students' responses from 4 colleges and universities. This study confirms that the scales which this study developed show high concurrent evidence with the college student's adaptability inventory for Korean university and college students based on various development process, specially rapid great change of college. The result of factor analysis shows the evidence based on internal structures of the scales. The Cronbach's ${\alpha}$ of the subscales is .965, from 742 to .937. The prediction model to determine the possibility of dropout by 7 scales is statistically significant in .05, except learning condition's stability. According to CFA Model, RMSEA= .08~.09. dependence factor variance are explained by this study's CFA model. In conclusion, this study confirms that the scales which this study developed are valid and reliable instrument for Korean university and college students to predict their adaptability to college.