• 제목/요약/키워드: Drop type

검색결과 921건 처리시간 0.025초

쓰레기 관로이송 시스템에서의 관로 압력손실 평가 (Evaluation of Pressure Drop in a Circular Pipe of Refuse Collecting System)

  • 김동우;장춘만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2615-2620
    • /
    • 2007
  • This paper describes on pressure drop in a circular pipe of refuse collecting system. The flow characteristics inside the circular pipe are analyzed by three-dimensional Navier-Stokes analysis. In numerical analysis, an organic waste is modeled using the data obtained by site survey. Pressure drop obtained by numerical simulation is compared to the value obtained by experimental measurements for the two kinds of pipe; straight and bended type. The pressure drop obtained by numerical simulation has a good agreement with that of experiments. It is noted that the accurate prediction of pressure drop in the waste pipe is very important to determine the performance of turbo blower used in making a suction pressure in the waste pipe. Especially, the pressure drop for an organic waste is analyzed according to the mass flow rate of waste.

  • PDF

선박 대기오염 저감을 위한 벽면 캐비티 적용 습식 사이클론의 집진특성 (Collection characteristics of wet-type cyclone with wall cavity for air pollutants removal of marine diesel engines)

  • 여석준;권준형
    • 수산해양기술연구
    • /
    • 제50권2호
    • /
    • pp.185-192
    • /
    • 2014
  • The main object of this study was to investigate the collection characteristics of wet-type cyclone with wall cavity. The experiment was executed to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, water spray type, inlet velocity etc. In results, for the present system of wet-type, the pressure drop represented 35 mm $H_2O$, while in dry-type 33 mm $H_2O$ showing lower 6% at $v_{in}=21m/s$. In case of $v_{in}=21m/s$ and water spray 200 mL/min, the collection efficiency of the present system became significantly higher as 96.8% comparing to that of the conventional wet-type scrubber. Additionally, for 200 mL/min, $SO_2$ removal efficiencies decreased with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}=6,9,12m/s$, respectively.

V형 원형휜-원형관의 강제대류 열유동 특성 (Forced Convection Characteristics of V type Circular-finned Tube Heat Exchanger)

  • 이종휘;임무기;강희찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1348-1354
    • /
    • 2009
  • The purpose of the present study is to investigate the flow resistance and the heat transfer characteristics of V type circular fin-tube heat exchanger. Four kinds of V type fin having the same fin area and the different span wise angle tested numerically. Test data for the heat transfer, pressure drop and fin temperature were shown and discussed. The pressure drop and heat transfer increased for decreasing the span wise angle up to 58% and 25% respectively.

  • PDF

A Modeling of Impact Dynamics and its Application to Impact Force Prediction

  • Ahn Kil-Young;Ryu Bong-Jo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.422-428
    • /
    • 2005
  • In this paper, the contact force between two colliding bodies is modeled by using Hertz's force-displacement law and nonlinear damping function. In order to verify the appropriateness of the proposed contact force model, the drop type impact test is carried out for different impact velocities and different materials of the impacting body, such as rubber, plastic and steel. In the drop type impact experiment, six photo interrupters in series close to the collision location are installed to measure the velocity before impact more accurately. The characteristics of contact force model are investigated through experiments. The parameters of the contact force model are estimated using the optimization technique. Finally the estimated parameters are used to predict the impact force between two colliding bodies in opening action of the magnetic contactor, a kind of switch mechanism for switching electric circuits.

유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구 (A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner)

  • 강정길;김종수
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

자동차용 공기분배장치의 성능개선에 관한 실험적 연구 (An Experimental Study on Performance Improvement of Automotive Air Handling System)

  • 유성연;이대웅;김진혁
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.622-629
    • /
    • 2007
  • Compact semi-center type automotive air handling system(AHS) is developed in this study and it's performance is compared with the conventional 3-pieces type air hand-ling system. The pressure drop is measured at component level and system level, and air flow rate and air distribution of discharge air through each ducts from air handling system are measured. System level characteristics of pressure drop at face and windshield discharge mode and air flow rate are investigated, and also temperature control linearities are tested. The volume of the air handling system package is reduced about 20%. And air flow rate increase about 5 to 20% compared to the conventional 3-pieces type air handling system at each discharge mode with significantly improved air pressure drop both component and system level. Also, air distribution and temperature controllability meet to evaluation criteria.

수평 T형 증발관내 2상류의 유량분배 및 압력강하 특성 (Characteristics of T-phase flow distribution and pressure drop in a horizontal T-type evaporator tube)

  • 박종훈;조금남;조홍기
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.658-668
    • /
    • 1999
  • The objective of the present study is to investigate the effect of experimental parameters on the hydrodynamic characteristics in a horizontal tee-type evaporator using R-22. The experimental apparatus consisted of an unheated tee-type test section, a liquid-vapor separator, a preheated, mass flow meters, a plate heat exchanger, pump, and other measurement devices. The experimental parameters were mass flux(500 and 600kg/$m^2$s), inlet quality(0.1~0.3) and separation ratio(0.3~0.7). Absolute pressure at the inlet of the test section was 0.652 MPa. The branch-to-inlet inner diameter ratio was 0.61. Pressure gradient at the branch section was larger than that at the run section at the same separation ratio. Pressure drop per unit length increased at the run section and decreased at the branch section as the separation ratio increased. Pressure drop predicted by the separated flow model agreed with experimental data within -35 to +16%. Generally, predicted values showed similar trend with the data. Mass flow ratio of vapor refrigerant was affected by the inlet quality more than the mass flux.

  • PDF

PGSFR 제어봉집합체 낙하성능시험 (Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor)

  • 이영규;김회웅;이재한;구경회;김종범;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

일체형원자로 제어봉구동장치의 낙하 및 완충특성 (Drop and Damping Characteristics of the CEDM for the Integral Reactor)

  • 최명환;김지호;허형;유제용
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.658-664
    • /
    • 2010
  • A control element drive mechanism(CEDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The ball-screw type CEDM for the integral reactor has a spring-damper system to reduce the impact force due to the scram of the CEDM. This paper describes the experimental results to obtain the drop and damping characteristics of the CEDM. The drop tests are performed by using a drop test rig and a facility. A drop time and a displacement after an impact are measured using a LVDT. The influences of the rod weight, the drop height and the flow area of hydraulic damper on the drop and damping behavior are also estimated on the basis of test results. The drop time of the control element is within 4.5s to meet the design requirement, and the maximum displacement is measured as 15.6 mm. It is also found that the damping system using a spring-hydraulic damper plays a good damper role in the CEDM.

충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구 (A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter)

  • 서정민;최금찬;박정호
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.