• Title/Summary/Keyword: Drop structure

Search Result 556, Processing Time 0.031 seconds

PEDOT:PSS Thin Films with Different Pattern Structures Prepared Using Colloidal Template

  • Yu, Jung-Hoon;Lee, Jin-Su;Nam, Sang-Hun;Boo, Jin-Hyo
    • Applied Science and Convergence Technology
    • /
    • v.23 no.5
    • /
    • pp.254-260
    • /
    • 2014
  • Organic solar cells have attracted extensive attention as a promising approach for cost-effective photovoltaic devices. However, organic solar cell has disadvantage of low power conversion efficiency in comparison with other type of solar cell, due to the recombination ratio of hole and electron is too large in the active layer. Thus we have change the surface structure of PEDOT:PSS layers to improve the current density by colloidal lithography method using various-size of polystyrene sphere. The two types of coating method were applied to fabricate the different pattern shape and height, such as spin coating and drop casting. Using the organic solvent, we easily eliminate the PS sphere and could make the varied pattern shapes by controlling the wet etching time. Also we have measured the electrical properties of patterned PEDOT:PSS film to check whether it is suitable for organic photovoltaics.

The modified HSINFET using the trenched hybrid injector (트렌치 구조의 Hybrid Schottky 인젝터를 갖는 SINFET)

  • 김재형;김한수;한민구;최연익
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.230-234
    • /
    • 1996
  • A new trenched Hybrid Schottky INjection Field Effect Transistor (HSINFET) is proposed and verified by 2-D semiconductor device simulation. The feature of the proposed structure is that the hybrid Schottky injector is implemented at the trench sidewall and p-n junction injector at the upper sidewall and bottom of a trench. Two-dimensional simulation has been performed to compare the new HSINFET with the SINFET, conventional HSINFET and lateral insulated gate bipolar transistor(LIGBT). The numerical results shows that the current handling capability of the proposed HSINFET is significantly increased without sacrificing turn-off characteristics. The proposed HSINFET exhibits higher latch-up current density and much faster switching speed than the lateral IGBT. The forward voltage drop of the proposed HSINFET is 0.4 V lower than that of the conventional HSINFET and the turn-off time of the trenched HSINFET is much smaller than that of LIGBT.

  • PDF

Novel Flexible Supercapacitors Fabricated by Simple Integration of Electrodes, Binders, and Electrolytes into Glass Fibre Separators

  • Yoo, Joung Eun;Bae, Joonho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.4
    • /
    • pp.237-244
    • /
    • 2014
  • We report novel and simple structure of supercapacitors fabricated by using flexible glass fibre separators as templates. This method does not require separate electrodes, binders and high pressure/temperature to build the supercapacitor unit cells as required by the conventional technology. The supercapacitors were fabricated by drop-casting solution mixtures of carbonaceous active materials/gel electrolytes onto two sides of glass fibre separators. Two carbonaceous materials (nanoscaled activated carbons, multi-walled carbon nanotubes) were investigated as electrode materials. The electrochemical measurements reveal that the separatorbased supercapacitors using ACs successfully demonstrated significant mass specific capacitance ($22.3F\;g^{-1}$) and energy density ($9.7Wh\;kg^{-1}$), indicating this method can be useful in fabricating flexible, wearable and stretchable energy storage devices in more straightforward and cost-effective way than current technology.

A Design of UHF Sensor using Partial Discharge Measurement in GIS (부분방전 측정용 UHF센서의 설계)

  • Park, K.S.;Kim, J.B.;Song, Y.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.28-30
    • /
    • 2002
  • The PD in GIS leads to a charge transfer and a voltage drop across the discharge area. They cannot be measure directly but we can measure electromagnetic wave made by PD. In generally, compared with VHF band, electromagnetic waves of UHF band have a low noise therefore, we can detect the real defect with several pC in GIS using UHF method. In this paper, the U-slot microstrip patch antenna for measuring PD signal in GIS is presented. the proposed UHF sensor are designed to have large band characteristics and unaffected structure for GIS operation.

  • PDF

Vibration Phenomena between Condensate Vertical Pump and Condenser Debris system in Power Plant (발전소 복수기 볼세정계통에 의한 입형펌프 진동과 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Yong-Chae;Lee, Hyun;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1020-1025
    • /
    • 2001
  • Vertical canned pumps are usually applied in the power plant to transport fluids that the available suction pressure is low at the condensate system and the circulating-water system. The top of the motor driver is 5.5m above the base and the barrel and drop column extend even further below the ground. While this size and configuration may produce an efficient pumping system, it also introduces several dynamic problems which must be considered in order to obtain a reliable operation. The main problem is that the vibrational mode of the long flexible cantilever structure above the ground exist near the operational characteristics of the condensate debris system. This system's trouble has been showed at 2,086 hp condensate water loading pumps in a nuclear power plant.

  • PDF

Numerical Performance Evaluation of an Ultra-small Lapple Cyclone Separator (초소형 Lapple 사이클론 집진기의 수치적 성능평가)

  • Park, Sumin;Kwon, Jae-Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.90-95
    • /
    • 2020
  • The purpose of this study is to numerically evaluate the collection performance of an ultra-small Lapple cyclone separator for 1~10 ㎛ particles introduced at flow rate of 10 L/min. The numerical evaluation reveals that a static pressure drop occurs more dominantly inside of the cyclone separator than at the inlet and the vortex finder. Also a fluid flow in the cyclone separator is confirmed to have a helical structure heading upward in the center of cyclone separator and downward in the vicinity of wall. The investigation on dust collection efficiency of the Lapple cyclone separator shows that particles of 4~8 ㎛ diameters are collected at very lower efficiency than other sizes. Then, the cut-point diameter of the cyclone separator is 1.48 ㎛.

Adaptive Reactive Power Control for Communication Errors of Hierarchical Wind Farm Management Systems (중앙집중형 풍력발전단지 제어관리시스템 전용 무효전력제어기 통신오류 보완에 관한 연구)

  • Seungmin Jung
    • Journal of Wind Energy
    • /
    • v.14 no.1
    • /
    • pp.44-51
    • /
    • 2023
  • Some controllers have been introduced in various studies to mitigate the negative effects of renewable sources. These have been modified to fit a formed solution in various ways. This paper deals with the voltage regulation of wind farms in voltage dip situations where communication failures occur. The aim is to discuss the modification of the online wind farm management system. To discuss modifications of the online wind farm management system, we focus on voltage regulation of wind farms when communication failures occur. The structure has been designed to respond to a voltage drop when the outer reference is absent due to communication errors. Since the loss reduction effect has been maintained in the designed case studies, it can be derived that the proposed method can respond to voltage drops, along with a used objective function.

Study of Catalytic Filter on the Removal of Dust and HVOC (촉매필터를 이용한 먼지 및 HVOC 제거 특성 연구)

  • Jeong, Soon Kwan;Park, Young Ok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Catalytic filter is capable of performing shallow bed dust filtration plus a catalytic reaction, promoted by a catalyst deposited in its inner structure. Such a feature may allow potential cost and space reduction in several environmental applications. Dust filtration and halogenated volatile organic compound (1,2-dichlorobenzene) destruction were carried out in a lab-scale reactor. $WO_3-V_2O_5/TiO_2$ supplied by MaGreen, which showed high catalytic acitivity at low temperature, was used as a catalyst. P-84 that can be operated under $250^{\circ}C$ was used as a felt. The catalytic activity and filtration efficiency of catalytic filters were investigated under the operating conditions, including temperature, face velocity, and dust concentration. The catalytic activity of catalytic filter increased with increasing temperature and the amount of catalyst loaded. The test results showed that the filtration efficiency was primarily affected by the face velocity. Pressure drop variations as a function of time were investigated for a variety of conditions. In case of virgin filter, a dramatic decrease in the pulse interval and a slightly increase in the base line pressure drop were observed. A relatively slow pressure drop build-up was recorded for the catalytic filter due to smooth and slippery surface characteristics of nanofiber. The catalytic filter indicated that high filtration efficiency over 99.98% and high catalytic activity over 90% at 1 m/min and $210^{\circ}C$.

Fatigue Analysis for Levitation Rail of Urban Maglev System (도시형 자기부상열차 부상레일의 피로해석)

  • Kim, Kyung-Taek;Kim, Jae-Yong;Kim, Yong-Hwan;Park, Jin-Soo;Pyen, Sang-Yun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.39-45
    • /
    • 2008
  • A levitation rail is placed on the top of track structure to operate Maglev vehicles and a part of track that link up with a sleeper is applied repeated load in Maglev vehicles operation. This paper aimed to verify validity of design for levitation rail, through the fatigue analysis about load which is applied to levitation rail in Maglev vehicles operation and impact load occurring in an emergency landing. Load conditions applied design load(23kN/m) in normal operation and skid drop load(24kN/m) in vehicle drop. And boundary conditions are consider bolt fixing and welding. Through static analysis, weak point and maximum stress of levitation rail could be obtained. S-N(stress-life) method was used in oder to predict fatigue life, and Goodman relationship was applied to consider a effect of mean stress. Also damage was calculated by using Miner's. As a result of fatigue analysis, levitation rail had a fatigue life which was more than requirement ($10^6$cycle) in all analysis conditions. Assumption that $10^8{\sim}10^9$cycles is infinite life, all analysis conditions had infinite life except a case under drop load and bolt fixing($1.21{\times}10^6$).

  • PDF

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.