Vibration Phenomena between Condensate Vertical Pump and Condenser Debris system in Power Plant

발전소 복수기 볼세정계통에 의한 입형펌프 진동과 대책

  • Published : 2001.11.01

Abstract

Vertical canned pumps are usually applied in the power plant to transport fluids that the available suction pressure is low at the condensate system and the circulating-water system. The top of the motor driver is 5.5m above the base and the barrel and drop column extend even further below the ground. While this size and configuration may produce an efficient pumping system, it also introduces several dynamic problems which must be considered in order to obtain a reliable operation. The main problem is that the vibrational mode of the long flexible cantilever structure above the ground exist near the operational characteristics of the condensate debris system. This system's trouble has been showed at 2,086 hp condensate water loading pumps in a nuclear power plant.