• Title/Summary/Keyword: Drop pattern

Search Result 276, Processing Time 0.023 seconds

Liquid Flow and Pressure Drop of an Outside Flow Membrane Oxygenator with Hollow Fibers (외부흐름 중공사 막형 인공폐의 액체흐름과 압력손실)

  • 이삼철;김기범
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • The purpose of this study was to evacuate the effects of the number of tied hollow fibers in a novel membrane oxygenator that satisfied the limiting factor of minimizing the friction loss in the intravascular blood flow Pattern. The membrane oxygenator is a bundle consisted of several hundred ho1low fibers haying the outside diameter of 380 $\mu m$ and the axial jacket length of 600 mm. The eight different variation of tied hollow fibers in a bundle were designed. and the liquid flow pattern was controlled by a pump. The liquid pressure drop was measured by in vitro experiments using water and g1ycero1. Uniform blood flow pattern was observed for each number of tied hollow fibers. Pressure drop was 13-16 mmHg outside of the membrane oxygenator consisting of up to 700 ho1low fibers. More effective contact of liquid with the tied ho1low fibers was observed as a decrease in the number of the tied hollow fibers. and resulted in the enhancement of the friction tractor

Micro Pattern Control of Metal Printing by Piezoelectric Print-head (압전 프린트 헤드에 의한 금속프린팅의 미세패턴제어)

  • Yoon, Shin-Yong;Choi, Geun-Soo;Baek, Soo-Hyun;Chang, Hong-Soon;Seo, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.147-151
    • /
    • 2011
  • We were analyzed the piezoelectric characteristic for electronics printing to inkjet printing system. These applications were possible use to Actuator, MEMS, FPCB, RFID, Solar cell and LCD color filter etc. Piezoelectric print head is firing from ink droplet control consideration ink viscosity properties. At this time, micro pattern for PCB metal printing was possible by droplet control of piezoelectric driving. These driving characteristics are variable voltage pulse waveform. We are used the piezoelectric analysis software of Finite Element Method (FEM), Piezoelectric design parameters are acquired from piezoelectric analysis, and measurement of piezoelectric. It designed for piezoelectric head to possible electric print pattern of inkjet printing system. For this validity we were established through in comparison with simulation and measurement. Designed piezoelectric specification obtained voltage 98V, firing frequency 10 kHz, resolution 360dpi, drop volume 20pl, nozzle number 256, and nozzle pitch 0.33 mm.

Flow-Dependent Friction Loss in an Implantable Artificial Lung

  • Lee, Sam-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1470-1476
    • /
    • 2002
  • The goal of this work is to design and build an implantable artificial lung that can be inserted as a whole into a large vein in the body with the least effect on cardiovascular hemodynamics. The experimental results demonstrate that the pressure drop is not entirely related to viscosity effects. The friction factor decreases with an increase in the number of tied-hollow fibers at a constant Reynolds number A uniform flow pattern without stagnation is observed at all numbers of tied hollow fibers tested. The tied hollow fiber module, built in this study with 3 cm of outer diameter of module. 380 m of outer diameter of tied hollow fiber, and 700 number of tied hollow fiber with length of 60 cm, which shows a pressure drop of 13-16 mmHg, satisfies the required pressure drop qualifying 15 mmHg as an intravascular artificial lung.

A Study on Influence Factors on Drop Formation in Electrohydrodynamic Atomization (전기수력학적 미립화에서 액적 형성에 영향을 미치는 인자에 관한 실험적 연구)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.8 no.2
    • /
    • pp.24-30
    • /
    • 2003
  • An experimental study was performed to investigate the influence factors of drop formation in electrohydrodynamic atomization. The mode of electrohydrodynamic atomization depended on the various factors such as the flow rate of the liquid, the inner diameter of the nozzle, the distance between the nozzle tip and the ground electrode, the shape of the ground electrode. and the applied high voltage. This work was performed to investigate the experimental analysis for the flow pattern visualization of droplets, and the relationship between voltage application and the behavior of liquid atomization. Uniform drops of different sizes can be obtained at the inception of the spindle mode by charging the flow rate and the electric field. The drop size also decreased when the flow rate was raised for the spindle mode. The whipping motion occurred beyond 7kV and before the corona started to take effect.

  • PDF

Energy Dissipation of Water Flow over a Drop

  • Lee, Jiyong;Lim, Yosup;Jang, Jinhee;Kang, Seokkoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.375-379
    • /
    • 2016
  • Recently derived energy dissipation equation by Chamani(2008) and the profile function of the free overfall by Marchi(1993) were verified with present experiment data. The experiment was conducted in hydraulic laboratory, Hanyang University where the flume is 7m long and 0.44m wide, and the height of the drop structure is 0.205m. Water depth and free overfall profile data were collected using an ultra sonic distance sensor and photographic images. The time-averaged water depth data and the free overfall profile were analyzed to examine the energy dissipation pattern over the drop structure

  • PDF

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

Vertical Stiffness and Lower Limb Kinematic Characteristics of Children with Down Syndrome during Drop Landing (드롭랜딩 동작 시 다운증후군 아동들의 수직 강성과 하지 운동학적 특성)

  • Koo, Dohoon;Maeng, Hyokju;Yang, Jonghyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.137-143
    • /
    • 2019
  • Objective: Ligament laxity and hypotonia are characteristics of Down syndrome patients. The aim of this study was to compare the landing pattern between Down syndrome patients and typically developing subjects. To compare the landing pattern, variables related to ligament laxity and hypotonia i.e. vertical stiffness and lower extremities kinematics were investigated. Method: Five subjects with Down syndrome (age: $14.6{\pm}1.8years$, mass: $47.6{\pm}6.94kg$, height: $147.9{\pm}6.0cm$) and six able-bodied subjects (age: $13.2{\pm}0.4years$, mass: $54.7{\pm}6.7kg$, height: $160.1{\pm}9.8cm$) participated in this study. Results: The vertical displacement of the center of mass, vertical reaction force, leg stiffness and range of ankle angle range among Down syndrome patients were significantly different than typically developing group. The youth with Down's syndrome appeared to receive greater vertical impact force at landing than normal youth. Conclusion: The differences in the biomechanical characteristics suggest the delay in motor development among Down syndrome patients and an increased risk of injury to the lower extremity during movement execution such as drop landing.

Ash Drop Measuring on Tobacco Leaf Grades and Brand Cigarettes (잎담배 및 제품담배의 재떨어짐에 관한 연구)

  • Yang Burm-Ho;Ahn Dae-Jin;Jo Si-Hyung;Jeh Byong-Kwon;Kim Si-Mong;Kim Byeoung-Ku
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.26 no.2 s.52
    • /
    • pp.117-125
    • /
    • 2004
  • In this study, we have investigated the natural and puffing combustibility of cigarette brands and the compulsory ash-drop, and analysed factors related to the materials. Cigarette combustibility was greatly affected by the tobacco weight in cigarettes rod. Combustion rate of 4AOR cigarette made by flue-cured tobacco was 5.02 $^{mm}/_{min}\;and\;10\%$ faster than 1BO cigarette. Combustion pattern has interrelation with sugars, chlorine and ash contents among tobacco components. Combustion rate of 4DL, flue-cured tobacco was 55 seconds faster than 1CL tobacco extremely much in sugars contents, and ash drop was maintained at $21\%$ longer. Combustion time and burning rate were fast in cigarette made by expanded tobacco slice and tobacco stem and the formation of ash was poor. The length of puffed ash drop of expanded tobacco slice and tobacco stem were 18.6 mm and 25.2 mm and these forced ash drop length were 3.8 mm and 4.9 mm respectively. Puffed burning rate of general cigarette was $14.3\%$ faster than static burning rate and super slim type cigarettes was $21.3\%$ faster. Combustion rate and ash drop of domestic and foreign cigarette brands were quite different depending on tar level and cigarette types. The lower tar level, the faster combustion rate and the shorter ash drop.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Gravity Level Dependency of Gas-Liquid Two-Phase Flow

  • Choi, Bu-Hong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.487-493
    • /
    • 2003
  • More reliable design of thermal transport. Power acquisition and thermal management systems requires the through understanding of the flow hydrodynamic. the differences and similarities between the two-phase flow characteristics of two-Phase flow influenced by the gravity levels. The data of flow Patterns, void fraction, frictional pressure drop associated with their characteristics were obtained at $\mu\textrm{g}$. 1g and 2g. Flow patterns and void fraction data obtained at three gravity levels were compared with each other and previous models and correlations.