• 제목/요약/키워드: Drinking water use

검색결과 237건 처리시간 0.018초

서울시민의 수돗물 인식과 실태파악을 통한 수돗물음용 활성화 연구 (Study on the Tap Water Drinking Promotion with Analysis of Current Status in Seoul Citizen)

  • 허정림;최경희;박석순
    • 한국환경교육학회지:환경교육
    • /
    • 제24권4호
    • /
    • pp.78-93
    • /
    • 2011
  • Clean and safe water is the fundamental element for the good life of people. However, expanding the distrust on the tap water increased the anxiety on drinking water and accelerated the growth of the natural and purified water market. In this respect, this study was made to find an opportunity to invigorate the use of the Seoul tap water for drinking by means of assessing the awareness of the citizen and the current condition on the tap water in Seoul. The findings were that the direct use of the tap water for drinking was very low and 'use after boiling' was also lower relative to 'use of purified water'. Also, the education on the environment should include the importance of the use of the tap water to improve the awareness of the citizen on the tap water and the administrative role, typically for educational institutes and schools, might be required to increase the use of the tab water for drinking.

  • PDF

서울시 수돗물 '아리수' 사용현황과 인식 분석을 통한 수돗물 직접 음용률 제고 방안 연구 (Study on Improvement of tap water drinking rate of Seoul city Tap water 'Arisu' through usage and recognition analysis)

  • 민새얀;김승인
    • 디지털융복합연구
    • /
    • 제16권9호
    • /
    • pp.399-404
    • /
    • 2018
  • 본 연구는 서울시 수돗물인 아리수의 음용률을 높이고, 지속적인 수질관리와 인식 제고를 위해 새로운 방안을 제시하는 것이 목적이다. 국내외 탭 워터 음용률을 높이기 위해 사용되었던 선행연구와 그에 관련된 사례를 분석하였다. 연구 범위는 수질 관리 시스템 Point-of-Use, Point-of-Entry 두 가지 변수 중 Point-of-Use로 한정하여 연구를 진행했으며 그 내용을 근거로 아리수의 직접 음용률이 얼마나 향상될지에 대하여 연구를 진행했다. 본 연구를 통해 국내는 사용자에게 오염된 수돗물을 단순히 정수작용을 거쳐 씻어내는 물로써 여과해준다는 기능을 제공하는 것이기에 수돗물을 마실 수 있는 물로서 인식개선 시키기엔 무리가 있다는 결론을 도출 하였고, 이를 통해 Point-of-Use 시스템의 장점이 탭 워터 자체 수질의 신뢰도를 상승시키고 음용수로서 인식을 개선할 수 있는 다양한 제품이 연구되기를 기대하며 이는 서울시 수돗물 아리수의 범위에서 더 나아가 전국 상수도 관리에도 적용 될 수 있을 것이라 기대된다.

서울지역 약수터에 대한 시민 여론 조사 (Survey of Citizens Public Opinion for Natural Spring Water in Seoul)

  • 김광래;길혜경;이만호;엄석원;이재영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권2호
    • /
    • pp.1-5
    • /
    • 2011
  • We surveyed the citizens opinion about springs in Seoul for two years from 2008 to 2009. It was found that spring water was mostly used by citizens older than 50, and that 29.5% of citizens used purified tap water as drinking water, 27.2% of them used boiled tap water, 21.1% of them used spring water, and 12.1% of them used bottled water. Citizens who store spring water more than a day are 76.7%. Although many citizens (70.3%) knew that water quality had been tested, 40% of them didn't care about checking the certificate of water quality analysis. Once recognized that the spring water was unfit for drinking exceeded standard of drinking water, 85% of citizens would rather not use the spring water.

학교음용수 관리 및 이용실태 (A Study on the Management & Utilization of School Drinking Water)

  • 홍정화;박영수
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제1권2호
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

Optimized Design of Dioxin Analysis for Water Sample

  • Choi, Jaewon;Lee, Jaehee;Kim, Kyoungsim;Kim, Sunheong;Bae, Kyunghee
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.219-229
    • /
    • 2005
  • The analytical methods for dioxins in water sample from wastewater to tap water were reviewed. For extraction method, liquid-liquid extraction (LLE) has been widely used, however, this process needs too much time and man power. New approach including solid phase extraction (SPE) is now applicable to large volume of water sample with high extraction efficiency. Column clean up in classical analytical methods were very complex and time consuming procedures during decade. Modifications were tried to decrease solvent and reagents volume. Moreover, use of column connection method has been demonstrated in the environmental matrices. Instrumental configurations also have been improved, in which GC/MS/MS with large volume injection approach can analyze picogram levels. Absolute sensitivities of HRMS increased compared to old versions of double focusing sector type mass spectrometers. Based on these analytical evolutions during last 10 years, we tried to optimize the analytical method for dioxins in water sample from sample extraction to instrumental analysis.

음용수질의 안정성을 위한 부식지수제도의 도입 (Introduction of Corrosion Index System for Stability of Drinking Water Quality)

  • 김영관;김진근
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

COVID-19 확산에 따른 상수도 사용량 변화 분석: 국내 S시 주거지역을 대상으로 (Analysis on drinking water use change by COVID-19: a case study of residential area in S-city, South Korea)

  • 정기문;강두선;김경필
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.11-21
    • /
    • 2022
  • 지난 2019년 말 발생한 COVID-19는 2020년을 기점으로 국내에 본격적으로 확산되기 시작하여, 사회 전반에 커다란 영향을 미치고 있다. COVID-19 확산을 억제하기 위한 방역수칙들은 인간 생활에 많은 변화를 가져왔으며, 사회적 거리두기 등 사회활동 제한에 따른 다양한 영향이 사회 전반에 걸쳐 나타나고 있다. 본 연구에서는 물 분야 COVID-19 위기 대응의 일환으로, COVID-19 확산에 따른 국내 상수도 사용량 변화를 분석하고, 상수도 사용량의 변화가 공급 서비스에 미치는 위협을 알아보고자 하였다. 국내 중소규모 도시인 S시 주거지역을 대상으로 COVID-19 확산 전후 일정기간 동안의 1시간 단위 용수 사용량 자료를 수집하였으며, 먼저 수집 데이터를 분석 목적에 따라 정제하고 전체 용수 사용량의 변화 및 사용 비중 변화, 그리고 시간별 용수 사용 패턴 변화 등을 분석하였다. 분석 결과, 가정용수 및 영업용수 사용량 및 이용패턴이 COVID-19 확산 이후 뚜렷한 변화를 보였으며, 일부 사용량 변화는 상수도 운영관리 차원에서의 검토가 필요한 것으로 나타났다.

SPE법에 의한 음료수중 농약성분 (Pesticide Analysis in Drinking Water by SPE Method)

  • 김형석
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.59-66
    • /
    • 1995
  • According to the population increase and industrialization, the drinking water source, Han River and other sources, are contaminated by industrial wastewater, domestic sewage, and agricultural discharges. Among the contaminants, and toxic substances, pesticides is most interesting items (or human health Our drinking water has some problems of THMs, Fe, odor, etc., $o many people use groundwater or bottled water. But sometimes there are many reports about groundwater contamination owing to the agricultural chemicals, waste disposal, industrial wastewater. In America, there are about 45,000 groundwave supply company and in korea about 20% of total population are using groundwave as drinking water source. In America, studies about SEE is increasing Instead of liquid- liquid extraction method, because of many advantages of SEE methods. Author tried to investigate SPE methods in the spiked water samples to compare with liquid- liquid extraction method and got the following results. The amount of organic solvents which are used In SPE method is less than 1/10 compared with liquid- liquid method, the analytical duration time is shortened, and the ethyl acetate was good fluent among several organic solvents.

  • PDF

수돗물 병입수 중 염소소독부산물 및 aldehyde의 발생 특성 (Characteristics of Chlorination Byproducts and Aldehyde Occurrence in Bottled Tap Water)

  • 이연희;박주현;김현구;안경희;김태승;김동훈;권오상
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.754-761
    • /
    • 2012
  • Several drinking water treatment plants (DWTPs) produce the bottled tap waters (BTWs) as pilot production and provide them for noncommercial use. In 2008, acetaldehyde and chloral hydrate were detected in some BTWs and the public worry over the safety of the water. In this study, the BTWs produced from 7 DWTPs were tested for 13 chemicals including disinfection byproducts (DBPs). The level of four trihalomethanes (THMs) were increased up to 15 days. The average concentration of them was 0.0075 mg/L at the time of bottling and it was increased to 0.0214 mg/L after 15 days. The average acetaldehyde concentration was 0.0406 mg/L at the time of bottling but it was went up to 0.2251 mg/L after 11 days and then decreased. Although the initial concentrations of DBPs were below the drinking water standard, we also traced them at different storage conditions. Temperature affected the formations of THMs and acetaldehyde concentrations significantly. While the average concentration of THMs ranged from 0.0113 to 0.0182 mg/L at $25^{\circ}C$, it was increased to 0.0132 ~ 0.0256 mg/L at $50^{\circ}C$. In case of acetaldehyde, concentration ranged from 0.0901 to 0.2251 mg/L at $25^{\circ}C$, it was increased to 0.3394 ~ 1.0591 mg/L at $50^{\circ}C$. Throughout the tests with 7 BTWs samples, none of the chemicals was exceeded the drinking water standard of Korea. Therefore, it is recommended to avoid the exposure of BTWs to sunlight or high temperature during distribution and storage.

대전지역 지하수에 함유된 우라늄 및 라돈의 함량 (Abundances of Uranium and Radon in Groundwater of Taejeon Area)

  • 한정희;박계헌
    • 자원환경지질
    • /
    • 제29권5호
    • /
    • pp.589-595
    • /
    • 1996
  • The concentration of radioactive elements was measured from the groundwater samples of Taejeon Area. U and Rn concentrations of very high level were detected from many places, especially around Yusung. These levels are much higher than the concentration standards for the drinking water proposed by the United States Environmental Protection Agency. However, in Korea, there are no standard levels for the radioactive elements in drinking water yet. We think that it is necessary to provide such standards as soon as possible, and that the determination of radioactive elements in groundwater should be included in the routine analysis items for the drinking water quality, because many people currently use such relatively high level radioactive groundwater as their drinking water, especially around Yusung area.

  • PDF