• Title/Summary/Keyword: Drain performance

Search Result 346, Processing Time 0.034 seconds

Performance Enhancement of Hybrid Doherty Amplifier using Drain bias control (Drain 바이어스 제어를 이용한 Hybrid Doherty 증폭기의 성능개선)

  • Lee Suk-Hui;Lee Sang-Ho;Bang Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.128-136
    • /
    • 2006
  • In this paper, design and implement 50W Doherty power amplifiers for 3GPP repeater and base station transceiver system. Efficiency improvement and high power property of ideal Doherty power amplifier is distinguishable; however bias control for implementation of Doherty(GDCHD) amplifier is difficult. To solve the problem, therefore, GDCHD(Gate and Drain Control Hybrid Doherty) power amplifier is embodied to drain bias adjustment circuit to Doherty power amplifier with gate bias adjustment circuit. Experiment result shows that $2.11{\sim}2.17\;GHz$, 3GPP operating frequency band, with 57.03 dB gain, PEP output is 50.30 dBm, W-CDMA average power is 47.01 dBm, and -40.45 dBc ACLR characteristic in 5MHz offset frequency band. Each of the parameter satisfied amplifier specification which we want to design. Especially, GDCHD power amplifier shows proper efficiency performance improvement in uniformity ACLR than Doherty power amplifier.

The Evaluation of Performance of Drain Pipes manufactured with Resin Concrete (레진 콘크리트로 제작한 하수관의 성능 평가)

  • 서정인;유성원;전성환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.57-62
    • /
    • 2002
  • Resin concrete has better properties than regular cement concrete in making structures such as manholes, pipes, etc. This study is to evaluate the performance of drain pipes made with resin concrete for the development its application. The test results have been checked by JSWAS K-11, because Korea does not have the code for its check-up. They satisfied all the requirements.

  • PDF

An Experimental Study on Reducing Condensation in Marine Air Compressors

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.303-308
    • /
    • 2015
  • Compressed air has many uses on board ship, ranging from diesel engine starting to the cleaning of machinery during maintenance. In an effort to enhance the performance of the marine compressed air system, this work studied a way to reduce condensation from the air compressor via experiments. Especially more condensation is produced when the temperature at compressor outlets and the humidity of the air are higher. so in the research, drain production change has been observed by additionally installing the cooling fan on the suction portion of the air to air compressor and this is the method for reducing the compressed air drain that has passed through the compressor. For the result, it was verified that when the cooling fan was used, less drain was made where per hour it was 500.9ml of drain and the measured result after installing the cooling fan was that less drain was made. Other additional and various researches are needed including experiments like silica gel passing through the suction portion afterwards.

Influence of Channel Length on the Performance of Poly-Si Thin-Film Transistors (다결정 실리콘 박막 트랜지스터의 성능에 대한 채널 길이의 영향)

  • 이정석;장창덕;백도현;이용재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.450-453
    • /
    • 1999
  • In this paper, The relationship between device performance and channel length(1.5-50$\mu$m) in polysilicon thin-film transistors fabricated by SPC technology was Investigated by measuring electric Properties such as 1-V characteristics, field effect mobility, threshold voltage, subthreshold swing, and trap density in grain boundary with channel length. The drain current at ON-state increases with decreasing channel length due to increase of the drain field, while OFF-state current (leakage current) is independent of channel length. The field effect mobility decrease with channel length due to decreasing carrier life time by the avalanche injection of the carrier at high drain field. The threshold voltage and subthreshold swing decrease with channel length, and then increase in 1.5 $\mu$m increase of increase of trap density in grain boundary by impact ionization.

  • PDF

Performance Test of PSD Oxidizer Drain Valve for KSLV-II (한국형발사체 PSD 산화제 배출밸브 성능시험)

  • Chung, Yonggahp;Han, Sangyeop;Kim, Suengik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1171-1175
    • /
    • 2017
  • Cryogenic helium gas is used as the pressurant for the oxidizer pressurization of DR(Damper Receiver) sphere in the PSD(Pogo Suppression Device) system and liquid oxygen is used as the oxidizer for the propellant in Korea Space Launch Vehicle-II. The helium gas is stored in pressurant cylinders inside the cryogenic liquid oxygen tank and liquid oxygen is stored in the oxidizer tank. In this study, the performance test of PSD liquid oxygen drain valve for KSLV-II was considered.

  • PDF

Simulation of Source/Drain Doping Effects and Performance Analysis of MoS2 Transistor

  • Kim, Chul-min;Park, Il Hoo;Lee, Kook Jin
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.285-287
    • /
    • 2016
  • 이황화 몰리브덴(Molybdenum disulfide: $MoS_2$)을 채널(Channel) 물질로 이용하여 metal-oxide-semiconductor(MOS) 구조를 제작하고, 효율적인 제작과정을 제시하였고 특히, Source/Drain의 Doping concentration을 조절하여 효과적인 $MoS_2$ Transistor를 제작 및 시뮬레이션 하였다. 그 후 여러 MOSFET의 특성 분석을 통하여 소자로서의 기능을 확인해보았다. 그리고 특히 채널의 전기적인 특성을 분석하고 채널 내 그리고 contact 사이의 저항 및 mobility의 특성을 알아보았는데, 그 중 Source/Drain Doping Effect와 performance 분석을 통해, 최적화된 $MoS_2$ Transistor를 찾아보았다.

  • PDF

Effects of Pentacene Thickness and Source/Drain Contact Location on Performance of Penatacene TFT (펜타센 박막의 두께와 전극위치가 펜타센 TFT 성능에 미치는 영향)

  • 이명원;김광현;송정근
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.12
    • /
    • pp.1001-1007
    • /
    • 2002
  • In this paper we analyzed the effects of pentacene thickness and the location of source/drain contacts on the performance of pentacene TFT Above a certain thickness of pentacene thin film the pentacene grain was turned from the thin film phase into the bulk phase, resulting in degrading the crystallinity and then performance as well. For the top contact structure in which source/drain contacts are located above pentacene film, the contact resistance decreased comparing with the bottom contact structure. However, the leakage current in the off-state became large and then the related parameters such as on/off current ratio were deteriorated. We found that the thickness of around 300$\AA$-700$\AA$ was suitable, and that the bottom contact was more feasible for hig Performance pentacene OTFT.

An Analysis of the Effect of a Variant Drain Orifice Damping on an Electrohydraulic Servovalve Flapper-Nozzle Stage (전기유압 서보밸브 플랩퍼-노즐에 대한 변동 배유 오리피스의 영향 해석 1)

  • Lee, Jae-Cheon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.50-59
    • /
    • 1999
  • The effect of a variant drain orifice damping on the characteristics of a servovalve flapper-nozzle stage is analyzed. Steady-state characteristics of flapper-nozzle stage and the linearized dynamics of flapper-nozzle assembly with a spool valve show that the variant drain orifice damping could improve such null performance characteristics as null pressure sensitivity and linearity of gain function. Generalized design criterion and a sufficient condition for servovalve stability are also established.

  • PDF

Engineering Characteristics of Horizontal Drainage for Stabilization of Dredged Fill (준설매립지반의 안정처리를 위한 수평배수재의 공학적 특성)

  • 이상호;박정용;장연수;박정순;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.563-570
    • /
    • 2001
  • In this study, the charactersistics of horizontal drains used to stabilize the dredged fill are investigated experimentally by doing tensile strength test, discharge capacity test, and filter clogging test. The types of the drains selected for the study are filament type (Tyre-E), embossed type(Type-P) and heat bonded cubic type with the thickness 10mm(Type-010) and 5mm(Type-05). The results of tensile strength and discharge capacity test show that the performance of drain Type-O10 was better than the other drains. This is caused by the fact that the lattice shape core of drain Type-O10 has strong rigidity and minimizes the loss of the sectional area of discharge with increased confining pressure. Analyzing the compatibility of filters by the results of the strength characteristics test and clogging test, the filter of filament type drain produced with polyester clothed polyamide performed well.

  • PDF

Performance of Horizontal Drainage in the Slope Using Numerical Analysis (수치해석을 이용한 비탈면 수평배수공의 성능 분석)

  • Sangyun Kim;Hoki Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.5-11
    • /
    • 2024
  • Due to the high proportion of mountainous terrain in Korean territory and the concentration of heavy rainfall during the summer season, concerns arise about the potential decrease in slope stability caused by rainfall. Installing slope drainage facilities mitigates the rise in groundwater levels due to infiltration, thus enhancing slope stability. Horizontal drains, classified as auxiliary facilities among drainage systems, lack established installation standards and related research. Slopes with installed horizontal drains have been confirmed to exhibit higher safety factors compared to those without. Furthermore, the safety factor of mimicking horizontal drains by increasing the permeability coefficient of the surrounding ground was compared with that of the conventional simulation method using the Drain function. As a result of the comparison, it was confirmed that the installation length showed better drainage performance than the installation angle in the drainage performance of the horizontal drainage hole, and it was judged that the installation length was a more important factor.