• Title/Summary/Keyword: Drain Rate

Search Result 187, Processing Time 0.027 seconds

A Study on the Labor Change in Mountainous Villages (산촌(山村)의 노동력(勞動力) 변화(變化)에 관(關)한 연구(硏究))

  • Yo, Byoung Il;Park, Myoung Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.45 no.1
    • /
    • pp.37-45
    • /
    • 1979
  • The purpose of the study was to define the labor change in the moutainous villages, So this study analyzed the mass dram of the population from the mountainous villages created by the unequal development between the first and second under the high economic development and the large difference in the income between city and rural area. The content of the study was (1) the foundation of the production in the survey area (2) labor change in the mountainous villages (3) the supply and the demand of the labor in this area. The date were collected from 118 household of 2 villages (one with a high level of brest product, and the other with a low level of forest products) in Cheon-nam Province through a questionarie. The results of the study were as follows. 1. The mass drain in the mountainous villages started in the middle of 1970's, and the rate of drain has been very rapid and accelerated. 2. The drain of the mountainous village with a low level of forest products is more than that of the mountainous village with a high level of forest products. 3. In the mountainous village with high level of forest products, the specialization in the farmer class has begun and the farmers with a side job are now increasing. 4. Generally the major drain consisted of the young class (16-30 age), and consequently it caused a change in the composition of labor power into old age and women. 5. The character of the forest labor market is how changing from closed to open.

  • PDF

An ABR Service Control for Improving Efficiency of PNNI (사설망인터페이스(PNNI)의 효율성 향상을 위한 ABR 서비스 제어)

  • Kim Byun-Gon
    • Science of Emotion and Sensibility
    • /
    • v.7 no.4
    • /
    • pp.67-75
    • /
    • 2004
  • In this paper, we analyze previous flow control algorithm for serving ABR traffic, and then propose the algorithm which calculate fair transmission rate and control efficiently ABR traffic using VS/VD switch which has an effect on PNNI environment with long delay. For getting the transmission rate, the proposed algorithm use FMMRA as ER scheme which calculate exactly the fair share. And, in large delay state, we can obtain fair cell sharing by calculating transmission rates which obtained by transmitted queue length information of VD to VS for serve and drain cell in queue Through the computer simulation, we evaluate the performance of proposed algorithm, According to the results, the proposed algorithm shows good performance.

  • PDF

Heat transfer and flow characteristics of a cooling thimble in a molten salt reactor residual heat removal system

  • Yang, Zonghao;Meng, Zhaoming;Yan, Changqi;Chen, Kailun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1617-1628
    • /
    • 2017
  • In the passive residual heat removal system of a molten salt reactor, one of the residual heat removal methods is to use the thimble-type heat transfer elements of the drain salt tank to remove the residual heat of fuel salts. An experimental loop is designed and built with a single heat transfer element to analyze the heat transfer and flow characteristics. In this research, the influence of the size of a three-layer thimble-type heat transfer element on the heat transfer rate is analyzed. Two methods are used to obtain the heat transfer rate, and a difference of results between methods is approximately 5%. The gas gap width between the thimble and the bayonet has a large effect on the heat transfer rate. As the gas gap width increases from 1.0 mm to 11.0 mm, the heat transfer rate decreases from 5.2 kW to 1.6 kW. In addition, a natural circulation startup process is described in this paper. Finally, flashing natural circulation instability has been observed in this thimble-type heat transfer element.

Calculation of the Attached-Piping-Material Rate for the Building Mechanical-Service System in Office Buildings (사무소 건축물의 건축기계설비 배관 부속자재 요율 산출)

  • Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.185-194
    • /
    • 2017
  • Currently, in comparison with other architectural estimations, the estimation work regarding building mechanical-service systems is time-consuming, and the process is continuously becoming more difficult because of the increased usage of the attached piping materials such as fittings and hangings in addition to their complicated construction processes. To improve this problem, the Korean authority provides a simple estimation method for the attached-material rate regarding the main piping material, which is the most time-consuming work in the architectural-mechanical estimation. However, to be an applicable method on construction sites, a proper conversion rate of the attached-piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the calculation of the rate of the attached-piping materials such as the fittings and supports through the building of the mechanical-service work types of mechanical rooms, air conditioning, domestic water and hot-water supplies, and the drain-, vent-, and gas-piping work in office buildings that have been designed after 2010.

Combined Treatment of Livestock Wastewater with Sewage Using Phanerochaete chrysosporium PSBL-1 (Phanerochaete chrysosporium PSBL-1을 이용한 축산폐수와 하수의 연계처리)

  • Lee, Soon-Young;Cho, Hong-Sik;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.286-291
    • /
    • 2006
  • We studied possibility of mixing treatment of livestock wastewater and sewage using Phanerochaete chrysosporium PSBL-1. Our study showed that 97.6% of SS and 95% of T-P removal efficiency was achieved when 2 mL BF02(a coagulant) and 100 mL C-210EL(a cationic polymer) were added to the mixture(2:1, v/v) of livestock wastewater and sewage. We studied treatment characteristic of Phanerochaete chrysosporium PSBL-1, after were mixed pretreated wastewater and sewage by dillution ten times about livestock wastewater. The removal efficiency of NBDCOD(non-biodegradable COD), $NH_3-N$ and T-N was increased according to increase of pH. That is, T-N concentration of effluent was satisfied 60 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities with 35 mg/L from a lapse of five days at pH 6.7, 51 mg/L from a lapse of three days at pH 8 and 33 mg/L from a lapse of one day at pH 10. Moreover $COD_{Mn}$ concentration of effluent was satisfied 40 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities after a laps of one day at all pH. Organics and nitrogen concentrations of effluent were higher case with addition of V.A.(veratryl alcohol) than case without addition of V.A.(veratryl alcohol). $COD_{Mn}$ concentration of effluent satisfied drain water qulity standard of livestock wastewater public treatment facilities from a lapse of one day, when C/N rate(3:1) of influent was not controled. T-N satisfied that from a lapse of two days, when C/N rate was controled with $4{\sim}6$.

Deleyed Cardiac Tamponade After Open Heart Surgery (Two Cases Report) (개심술후에 발생한 지연성 심장압진증)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.218-221
    • /
    • 1982
  • Delayed cardiac tamponade in an uncommon and frequently fatal complication after open-heart surgery. We had been experienced two cases of delayed cardiac tamponade as a complication of open-heart surgery and treated successfully by reinsertion of pericardial drain through subxiphoid route. First case was 60 years old female patient and underwent MVR under impression of MSi + Ti Second case was 19 years old male patient and underwent total correction of T.O.F.with Blalock shunt [Lt]. Both cases had Initial symptoms, which were epigastric pain, chest tightness, dropped blood pressure, and increased pulse rate and respiratory rate, mimic as low cardiac output syndrome after open-heart surgery. Roentgenogram of the chest showed a rapid increased cardiothoracic ratio. It is important to realize the presence of late cardiac tamponade for proper diagnosis of complication after open-heart surgery.

  • PDF

Comparison of Stain Rate-Dependent Consolidation Behaviors of Olga-C Embankment with and without Vertical Drains (배수재 설치 및 미설치 구역으로 구성된 Olga-C 성토지반의 변형률 속도 의존적인 압밀거동 비교)

  • Kim, Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.3
    • /
    • pp.39-46
    • /
    • 2000
  • 본 논문에서는 배수재가 설치된 구역과 설치되지 않은 구역으로 구성된 Olga-C 시험성토지반의 변형률속도 의존적인 압밀거동을 서술하였다. 배수재가 설치된 지반이 압밀거동에 대한 변형률속도의 영향을 해석하기 위하여 응력-변형률-변형률 속도의 관계식(v-$\varepsilon$v- v)을 이용한 축대칭 비선형 점소성 모델을 제안하였다. 제안된 모델은 실험실과 현장의 변형률속도 차이뿐만 아니라 간극수압의 소산과 생성의 복합적인 압밀과정을 고려할 수 있다. 연직 및 반경방향의 배수효과에 의해 배수재가 설치된 지반(Zone B)에서 유발되는 변형률 속도는 배수재가 설치되지 않은 연약지반 (Zone A)의 변형률 속도보다 크다. 유발된 변형률 속도의 영향으로 Zone B의 선행압밀하중도 Zone A에서 유발되는 선행압밀하중보다 크다. Olga-C 지역의 Zone A 에서는 응력완화효과가 유발되지만, Zone B에서는 응력완화효과가 유발 되지 않았다.

  • PDF

Drainage Performance of Various Subsurface Drain Materials- (배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능-)

  • 김철회;이근후;유시조;서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF

Relationships of Loading Rates and Bearing Capacities on Intermediate Soils (재하속도를 이용한 중간토의 지지력 평가)

  • 박중배
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.101-114
    • /
    • 1996
  • In this study, the characteristics of bearing capacity and deformation of intermediate soils are investigated through centrifuge tests. The experimental parameters are footing width, initial stress condition of soils and relative loading rate defined relationship of loading rate and permeability of soils. It is examined that loading rate influences on the bearing capacities and deformations. Based on the test results, some problem of existing specification are introduced in the view of related loading rates and load intensities. Especially it is showed that load intensities magnitude rlre reversed in the same settlement ratio(s/B(%)), due to partial drained effect as well as loading rates in undrained con dition based on the excess pore pressure and deformations measured under loading.

  • PDF

Constant Rate of Strain Consolidation Test for Radially inward drainage (일정변형률 압밀시험을 이용한 방사내측배수 압밀해석)

  • Yune, Chan-Young;Yang, Bong-Keun;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.173-180
    • /
    • 2004
  • In this study, a consolidometer for radially inward drainage under constant rate of strain (CRS) loading was developed. Theoretical solutions for determining the effective vertical stress and the coefficient of consolidation from the test result were also proposed. Reconstituted kaolinite samples which were consolidated up to 130 kPa were used to verify the developed consolidometer and the theory. Comparative experiments with CRS loading and incremental loading (IL) were carried out in radially in ward drainage as well as vertical and radially outward drainage. The results obtained from the developed CRS loading test agreed consistently with those of the conventional incremental loading test according to drainage directions. And the effect of drainage direction and drain diameter to consolidation characteristics was also evaluated. From the test results the applicability and the reliability of the suggested method were verified.

  • PDF