• 제목/요약/키워드: Double-skin

검색결과 294건 처리시간 0.026초

커튼월 건축물의 이중외피 시스템 적용에 따른 에너지 부하량 검토 (A Study on the Energy Load of the Curtain Wall Buildings according to the Application of the Double-skin Facade System)

  • 리바이홍;이준기;김성훈;이갑택;김동완;이경희
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.99-104
    • /
    • 2016
  • In this study, we researched the energy load according to the change of the inner window area ratio, the distance of the air gap and the azimuth of the curtain wall building, which installed the multistory double-skin facade(DSF). and we compared the results with the no double-skin facade situation as follows. With the DSF, it is better than other case, when the window area ratio is 40% and the air gap is 1.2m on the west, south-45-west, south-45-east and east. And it's best when the window area ratio is 40% and the air gap is 0.4m on the south. And on the east or south-45-east, the window area ratio is 40% and the air gap is 1.2m is better than other case with the DSF. On south, it is best when the window area ratio is 100% without DSF. On the south-45-west or west, it is best when the window area ratio is 40% without the DSF.

Double-layered collagen graft to the radial forearm free flap donor sites without skin graft

  • Park, Tae-Jun;Kim, Hong-Joon;Ahn, Kang-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.45.1-45.8
    • /
    • 2015
  • Background: Radial forearm free flap is the most reliable flap for intraoral soft tissue reconstruction after cancer ablation surgery. However, unesthetic scar of the donor site and the need for a second donor site for skin graft are major disadvantages of the forearm flap. The purpose of this study was to report the clinical results of double-layered collagen graft to the donor site of the forearm free flap without skin graft. Methods: Twenty-two consecutive patients who underwent oral cancer ablation and forearm reconstruction between April 2010 and November 2013 were included in this study. Male to female ratio was 12:10, and average age was 61.0 years old (27-84). Double-layered collagen was grafted to the donor site of the forearm free flap and healed for secondary intention. Upper silicone had been trimmed at the periphery during secondary intention, and dry dressing was used. Postoperative scar healing and esthetic results and function were evaluated. Results: An average follow-up period was 34.9 months. The scar area was decreased to 63.9 % in average. The complete healing was obtained between 1.5 and 3 months according to the defect size. There was no functional defect or impairment 3 months after operation. All patients were satisfied with the esthetic results. Three patients died of recurred cancer. Conclusions: Double-layered collagen graft was successfully performed in this study. Without the thigh skin graft, patients had experienced less painful postoperative healing periods and discomfort.

이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구 (An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer)

  • 김동균;윤갑천;강재식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

유조선의 선체손상 시 기름의 해상유출에 대한 실험적 연구 (An Experimental Study on the Oil Spillage of Damaged Oil Tanker)

  • 김을년;하우일;최익흥
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.398-408
    • /
    • 2009
  • Crude oil carriers or product oil carriers are confronted with sea pollution due to hull damage from various accidents. To reduce the oil spillage of tankers, IMO(International Maritime Organization) and OPA 90(Oil Pollution Act 1990) adopted the hull structures of double skin type. In this study, oil spillage test of the double skin tanker with 1/100 scaled model was carried out under damaged condition due to collision and grounding accidents. A new structural type of oil tanker was also tested with pipe and valve system arranged in double side and single bottom hulls. Their results were compared with that of conventional type double hull on the view point of ship safety and oil spillage.

박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교 (A Study on thermal performance of box type double skin facade and curtain wall in heating period)

  • 박창영;최창호;이건호;윤용상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

Flexural performance of double skin composite beams at the Arctic low temperature

  • Yan, Jia-Bao;Dong, Xin;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.431-446
    • /
    • 2020
  • This paper presents the flexural performance of double skin composite beams (DSCBs) at different Arctic low temperatures. 12 DSCBs were prepared and tested under two-point loading at different Arctic low temperatures of 20, -30, -50, and -70℃. The studied parameters include low-temperature level (T), steel-faceplate thickness (t), shear span ratio (λ), and spacing of headed studs (S). The experimental investigations under two-point loading tests showed that flexural failure occurred to all DSCBs, even including the specimen designed with the small λ ratio of 2.9. The ultimate strength behaviours of DSCBs were improved due to the improved mechanical properties of constructional materials and the confinement on shear connectors. The DSCB subjected to two-point loading and low temperatures exhibits a five-stage working mechanism. The stiffness and strength indexes of DSCBs increase linearly with temperature and t value increasing, while decreasing as shear span ratio boosts. In the contrast, the change of S value from 150 to 200 mm has little effect on the ultimate strength behavior of DSCB.

Behavior of L-shaped double-skin composite walls under compression and biaxial bending

  • Qin, Ying;Chen, Xin;Xi, Wang;Zhu, Xingyu;Chen, Yuanze
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.405-418
    • /
    • 2020
  • The application of double-skin composite wall should meet different layout plans. However, most available research focused on the rectangular section with uniform axial compression. In this research, the structural behavior of double-skin composite wall with L section was studied. Due to the unsymmetric geometric characteristics, the considered loading condition combined the axial compression and biaxial bending. Five specimens were designed and tested under eccentric compression. The variables in the test included the width of the web wall, the truss spacing, the thickness of the steel faceplate, and the thickness of the web wall. The test results were discussed in terms of the load-displacement responses, buckling behavior, stiffness, ductility, strength utilization, strain distribution. Two modern codes were employed to predict the interaction between the axial compression and the biaxial bending. The method to calculate the available bending moment along the two directions was proposed. It was found that CECS 159:2004 offers more suitable results than AISC 360.

Finite element model for interlayer behavior of double skin steel-concrete-steel sandwich structure with corrugated-strip shear connectors

  • Yousefi, Mehdi;Ghalehnovi, Mansour
    • Steel and Composite Structures
    • /
    • 제27권1호
    • /
    • pp.123-133
    • /
    • 2018
  • Steel-concrete-steel (SCS) sandwich composite structure with corrugated-strip connectors (CSC) has the potential to be used in buildings and offshore structures. In this structure, CSCs are used to bond steel face plates and concrete. To overcome executive problems, in the proposed system by the authors, shear connectors are one end welded as double skin composites. Hence, this system double skin with corrugated-strip connectors (DSCS) is named. In this paper, finite element model (FEM) of push-out test was presented for the basic component of DSCS. ABAQUS/Explicit solver in ABAQUS was used due to the geometrical complexity of the model, especially in the interaction of the shear connectors with concrete. In order that the explicit analysis has a quasi-static behavior with a proper approximation, the kinetic energy (ALLKE) did not exceed 5% to 10% of the internal energy (ALLIE) using mass-scaling. The FE analysis (FEA) was validated against those from the push-out tests in the previous work of the authors published in this journal. By comparing load-slip curves and failure modes, FEMs with suitable analysis speed were consistent with test results.

이중외피 중공층의 열성능을 고려한 블라인드 위치 계획 (Planning the Blind Position Considering Thermal Performance in the Intermediate Space of Double-Skin Facade)

  • 최동희;조재훈;석호태;여명석;김광우
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.620-628
    • /
    • 2005
  • The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divide the airflow of intermediate space into two, thermal performance of Double-Skin Facade (DSF) are affected by the blind position. Therefore blind position should be planed with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was peformed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer-facade. In the other cases, the blind should maintain 0.15 m distance from outer-facade.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.