Browse > Article
http://dx.doi.org/10.12989/scs.2018.27.1.123

Finite element model for interlayer behavior of double skin steel-concrete-steel sandwich structure with corrugated-strip shear connectors  

Yousefi, Mehdi (Civil Engineering Department, Faculty of Maritime Engineering, Chabahar Maritime University)
Ghalehnovi, Mansour (Civil Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad)
Publication Information
Steel and Composite Structures / v.27, no.1, 2018 , pp. 123-133 More about this Journal
Abstract
Steel-concrete-steel (SCS) sandwich composite structure with corrugated-strip connectors (CSC) has the potential to be used in buildings and offshore structures. In this structure, CSCs are used to bond steel face plates and concrete. To overcome executive problems, in the proposed system by the authors, shear connectors are one end welded as double skin composites. Hence, this system double skin with corrugated-strip connectors (DSCS) is named. In this paper, finite element model (FEM) of push-out test was presented for the basic component of DSCS. ABAQUS/Explicit solver in ABAQUS was used due to the geometrical complexity of the model, especially in the interaction of the shear connectors with concrete. In order that the explicit analysis has a quasi-static behavior with a proper approximation, the kinetic energy (ALLKE) did not exceed 5% to 10% of the internal energy (ALLIE) using mass-scaling. The FE analysis (FEA) was validated against those from the push-out tests in the previous work of the authors published in this journal. By comparing load-slip curves and failure modes, FEMs with suitable analysis speed were consistent with test results.
Keywords
steel-concrete-steel sandwich; corrugated-strip connectors; push-out test; explicit analysis; mass-scaling;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 ABAQUS, S.M. and Manual, E.U.s. (2010), "Hibbitt", Karlsson & Sorensen Inc., Pawtucket, RI, USA.
2 Bowerman, H. and Chapman, J. (2000), "Bi-steel concrete steel sandwich construction", Proceedings of the 4th US Engineering Foundation Conference on Composite Construction, June.
3 Foundoukos, N. and Chapman, J. (2008), "Finite element analysis of steel-concrete-steel sandwich beams", J. Constr. Steel Res., 64(9), 947-961.   DOI
4 Huang, Z. and Liew, J. (2016), "Numerical studies of steelconcrete- steel sandwich walls with J-hook connectors subjected to axial loads", Steel Compos. Struct., Int. J., 21(3), 461-477.   DOI
5 Lee, J. and Fenves, G.L. (1998), "Plastic-damage model for cyclic loading of concrete structures", J. Eng. Mech., 124(8), 892-900.   DOI
6 Leekitwattana, M., Boyd, S. and Shenoi, R. (2010), "An alternative design of steel-concrete-steel sandwich beam", Proceedings of the 9th International Conference on Sandwich Structures.
7 Leekitwattana, M., Boyd, S. and Shenoi, R. (2011), "Evaluation of the transverse shear stiffness of a steel bi-directional corrugatedstrip-core sandwich beam", J. Constr. Steel Res., 67(2), 248-254.   DOI
8 Liew, J.R. and Sohel, K. (2009), "Lightweight steel-concrete-steel sandwich system with J-hook connectors", Eng. Struct., 31(5), 1166-1178.   DOI
9 Lubliner, J., Oliver, J., Oller, S. and Onate, E. (1989), "A plasticdamage model for concrete", Int. J. Solids Struct., 25(3), 299-326.   DOI
10 Liew, J.R., Sohel, K. and Koh, C. (2009), "Impact tests on steel- concrete-steel sandwich beams with lightweight concrete core", Eng. Struct., 31(9), 2045-2059.   DOI
11 Shanmugam, N., Kumar, G. and Thevendran, V. (2002), "Finite element modelling of double skin composite slabs", Finite Elem. Anal. Des., 38(7), 579-599.   DOI
12 Shariati, M., Sulong, N.R., Suhatril, M., Shariati, A., Khanouki, M.A. and Sinaei, H. (2012), "Behaviour of C-shaped angle shear connectors under monotonic and fully reversed cyclic loading: an experimental study", Mater. Des., 41, 67-73.   DOI
13 Smitha, M. and Kumar, S.S. (2013), "Steel-concrete composite flange plate connections-finite element modeling and parametric studies", J. Constr. Steel Res., 82, 164-176.   DOI
14 Solomon, S., Smith, D. and Cusens, A. (1976), "Flexural tests of steel-concrete-steel sandwiches", Mag. Concrete Res., 28(94), 13-20.   DOI
15 Wright, H. and Oduyemi, T. (1991), "Partial interaction analysis of double skin composite beams", J. Constr. Steel Res., 19(4), 253-283.   DOI
16 Soty, R. and Shima, H. (2011), "Formulation for maximum shear force on L-shape shear connector subjected to strut compressive force at splitting crack occurrence in steel-concrete composite structures", Procedia Engineering, 14, 2420-2428.   DOI
17 Tomlinson, M., Tomlinson, A., Li Chapman, M., Jefferson, A. and Wright, H. (1989), "Shell composite construction for shallow draft immersed tube tunnels", Immersed Tunnel Techniques: Proceedings of the Conference.
18 Valente, I. and Cruz, P.J. (2010), "Experimental analysis on steel and lightweight concrete composite beams", Steel Compos. Struct., Int. J., 10(2), 169-185.   DOI
19 Yan, J.-B. (2015), "Finite element analysis on steel-concrete-steel sandwich beams", Mater. Struct., 48(6), 1645-1667.   DOI
20 Xie, M., Foundoukos, N. and Chapman, J. (2005), "Experimental and numerical investigation on the shear behaviour of frictionwelded bar-plate connections embedded in concrete", J. Constr. Steel Res., 61(5), 625-649.   DOI
21 Yan, J.-B., Liew, J.R., Zhang, M.-H. and Wang, J. (2014), "Ultimate strength behavior of steel-concrete-steel sandwich beams with ultra-lightweight cement composite, Part 1: Experimental and analytical Study", Steel Compos. Struct., Int. J., 17(6), 907-927.   DOI
22 Yan, J.-B., Liew, J. and Zhang, M.-H. (2015), "Ultimate strength behavior of steel-concrete-steel sandwich beams with ultralightweight cement composite, Part 2: Finite element analysis", Steel Compos. Struct., Int. J., 18(4), 1001-1021.   DOI
23 Zou, G.P., Xia, P.X., Shen, X.H. and Wang, P. (2016), "Investigation on the failure mechanism of steel-concrete steel composite beam", Steel Compos. Struct., Int. J., 20(6), 1183-1191.   DOI
24 Yousefi, M. and Ghalehnovi, M. (2017), "Push-out test on the one end welded corrugated-strip connectors in steel-concrete-steel sandwich structure", Steel Compos. Struct., Int. J., 24(1), 23-35.   DOI