Double Pulse Raman-Laser Induced Plasma Spectroscopy System for Space Exploration (우주 탐사를 위한 이중펄스 라만-레이저 유도 플라즈마 분광 시스템 개발 연구)

  • Yang, Jun-Ho;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.479-487
    • /
    • 2020
  • A new double-pulse laser system that combines Raman and laser induced plasma spectroscopy (LIPS) in a single unit is proposed. The study attempts to enhance the laser induced plasma signals while simultaneously extracting the desired molecular signals from Raman spectroscopy. In low pressure conditions such as the lunar atmosphere, the measuring of plasma emission is hard because of the low electron density and short persistence time causing a rapid plasma expansion. Furthermore, in the integration of the detecting system aimed at space exploration, the minimization of laser system is important in terms of the payload mass. Simultaneous molecular and atomic detection that gave highly resolved spectral data at pressure below 0.07 torr is demonstrated amongst eight rock samples test. The plasma stacking produced from the double-pulse laser enhanced the signal intensity of calcium and oxygen lines in calcite matrix by twofold, compared to a conventional LIPS.

Using Pulse-Front Tilt to Measure Laser Pulses Less Than 100 Picoseconds in Duration

  • Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.318-321
    • /
    • 2015
  • We demonstrate a frequency-resolved optical grating (FROG) device for measuring the intensity and phase versus time of several-tens-of-picoseconds laser pulses, using a thick nonlinear optical crystal. The huge pulse-front tilt generated by a holographic grating increases the temporal range of the device, which can make a single-shot measurement of laser pulses less than 100 ps in duration. To verify the measurement technique, we generate double pulses using a Michelson interferometer. The measured duration of a single pulse is about 300 fs and the measured maximum delay of two pulses is 60 ps, which implies that the proposed FROG device can measure laser pulses with maximum pulse width of about 120 ps.

High-power Femtosecond Ti:sapphire Laser at 1 KHz with a Long-cavity Femtosecond Oscillator

  • Sung, Jae-Hee;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.135-138
    • /
    • 2003
  • A chirped-pulse amplification femtosecond Ti:sapphire laser operating at 1 KHz has been developed. The laser system consisted of a long-cavity femtosecond oscillator, a four-pass grating pulse stretcher, two multi-pass amplifiers and a double-pass grating pulse compressor. Thermal lensing at the amplifiers was reduced by cooling Ti:sapphire crystals using Peltier coolers. Gain narrowing and residual phase errors were compensated for by the use of an acousto-optic pulse shaper. The final laser output had an energy per pulse of 2.0 mJ and a pulse duration of 19.5 fs, reaching 0.1 TW at 1 KHz.

Precision exploration of space resources using laser-induced breakdown spectroscopy (레이저 유도 플라즈마 분광분석법을 활용한 정밀 우주 자원 탐사)

  • Choi, Soo-Jin;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.451-457
    • /
    • 2011
  • A short laser pulse irradiates a sample to create the highly energetic plasma that emits light of a specific wavelength peak according to the material. By identifying different peaks for the analyzed samples, its chemical composition can be rapidly determined. The LIBS (Laser-Induced Breakdown Spectroscopy) has great advantages as an elemental analyzer on board a space rover, namely real-time rapid analysis and stand-off detection. The LIBS signal intensity is remarkably increased by using double-pulse LIBS system for component analysis of lunar environments where the surrounding pressure is low. Also the angle of target is adjusted for replicating arbitrary shapes of the specimen.

Study of Laser Trimming and Cutting of Printed Circuit Board by using UV Laser with Nanosecond Pulse Width (나노초 펄스폭을 갖는 자외선 레이저를 이용한 전자회로기판의 저항체 트리밍과 절단공정 특성에 관한 연구)

  • Ryu, Kwang-Hyun;Shin, Suk-Hoon;Park, Hyeong-Chan;Nam, Gi-Jung;Kwon, Nam-Ic
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.23-28
    • /
    • 2010
  • Resistance trimming and cutting processes of printed circuit board by making use of high power UV laser with nano-second pulse width have been proposed and investigated experimentally. Also laser-based application system with high flexibility and complex has been designed and adopted power controller, auto beam size control, auto-focusing and control program developed for ourselves. The function of each module shows that they can be reliable for industrial equipments. Resistance trimming method used a plunge and double cut process with $20{\mu}m$ spot size beam. Results show that double cut process is more effective to control resistance trimming in precision than plunge cut process.

Step Pulse Shaping Technique for Nd:YAG Laser Using a Multi-Switching Method

  • Kwak, Su-Young;Park, Jin-Young;Kim, Su-Weon;Min, Byoung-dae;Chung, Hyun-ju;Kim, Hee-je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.55-59
    • /
    • 2004
  • Throughout manufacturing processes, pulse shaping is required for material processing and it is regarded as an important (actor according to the specific characteristics of materials. Therefore, this study suggests a highly appropriate pulse shaping technique using a multi-switching method. This is a pulse superposition method in which one flash lamp can consecutively turn on by the double switching of the discharging system. It is possible to construct a variety of pulse shapes and pulse widths by the consecutive trigger of the silicon-controlled rectifiers (SCR) of a PIC (program integrated circuit) one-chip microprocessor. The use of this technique can provide a number of advantages to people who require suitable pulse shaping for particular applications such as welding, cutting, and drilling.

Development of New Holography System for Measurments of Particle Velocities Using Separation of Images (이미지 분리를 이용한 입자 속도 측정을 위한 홀로그래피 시스템의 개발)

  • Kang, B.S.;Poulikakos, D.
    • Journal of ILASS-Korea
    • /
    • v.2 no.2
    • /
    • pp.16-23
    • /
    • 1997
  • In this research a novel two-reference-beam double pulse holographic technique for the measurments of particle sizes and velocities was developed. This holographic method features the capability of separation of the first and second particle images by using two reference beams instead of one and the change of the polarization direction of laser light. The developed holographic system was tested through the measurements of droplet sizes and velocities in the spray created by two high speed impinging jets. The overall spray pattern clearly revealed the inherent wave nature. Smaller and faster droplets were generated with larger impingement angle, higher jet velocity. and smaller orifice diameter.

  • PDF

Development of Digital Holographic Microscopy System for Measurements of Particle Velocities in MR Fluids (MR 유체 입자 속도 계측을 위한 디지털 홀로그래피 현미경 시스템의 개발)

  • Chen, He-Peng;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.21 no.2
    • /
    • pp.88-94
    • /
    • 2016
  • In this study digital holographic microscopy system for measurements of 3-D velocities of particles in MR fluid is developed. Holograms are recorded using either a CCD camera with a double pulse laser or a high-speed camera with a continuous laser. To process recorded holograms, the correlation coefficient method is used for focal plane determination of particles. To remove noise and improve the quality of holograms and reconstructed images, a Wiener filter is adopted. The two-threshold and image segmentation methods are used for binary image transformation. For particle pairing, the match probability method is adopted. The developed system will be applied to measurements of the characteristics of unsteady 3-D particle velocities in MR fluids through the next stage of this study.

Low Temperature Poly-Si TFTs with Excimer Laser Annealing on Plastic Substrates (플라스틱 기판위에 엑시머 레이저 열처리된 저온 다결정 실리콘 박막 트랜지스터)

  • Choi, Kwang-Nam;Kwak, Sung-Kwan;Kim, Dong-Sik;Chung, Kwan-Soo
    • 전자공학회논문지 IE
    • /
    • v.43 no.2
    • /
    • pp.11-15
    • /
    • 2006
  • In this paper characteristics of polycrystalline silicon crystallized by excimer laser on plastic substrate under 150$^{\circ}C$ is investigated. Amorphous silicon is deposited by rf-magnetron sputter in atmosphere of Ar and He for preventing depletion effect by dehydrogenation as deposition by PECVD. After annealing by 308 nm, 30 Hz, double pulse type XeCl excimer laser, p-chnnel low temperature polycrystalline silicon TFT which maximum mobility is $64cm^2/V{\cdot}s$ at $344mJ/cm^2$ is fabricate.

Quasi-continuous-wave Yb-doped Fiber Lasers with 1.5 kW Peak Power (첨두 출력 1.5 kW급 준연속 이터븀 첨가 광섬유 레이저)

  • Jeon, Minjee;Jung, Yeji;Kim, Jiwon;Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.3
    • /
    • pp.95-100
    • /
    • 2016
  • High-power quasi-continuous-wave (qcw) operation in Yb-doped double-clad fiber lasers with near-diffraction-limited quality of the output beam is reported. Based on numerical simulation, we built a simple, all-fiberized Yb fiber laser, and a fiber-based master-oscillator power amplifier (MOPA). Both laser systems have successfully produced qcw output with average power greater than 150 W at 1080 nm and 10 ms pulse duration at 10 Hz repetition rate, corresponding to a peak power greater than 1.5 kW for 205 W of pump power at 976 nm. Laser performance, including beam quality and slope efficiency, was characterized in both configurations. Prospects for power scaling and applications are discussed.