• Title/Summary/Keyword: Double Facade

Search Result 57, Processing Time 0.02 seconds

Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period (난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구)

  • Lee, Keon-Ho;Kim, Hyeon-Soo;Ko, Yung-Woo;Son, Young-Joo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

Natural Ventilation in High-Rise Building with Double Facades, saving or waste of Energy

  • Lee, Eung-Jik;Pasquay, Till
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.39-45
    • /
    • 2002
  • Double facades are built to allow natural ventilation in high rise buildings and buildings with high outside noise level. In high rise Buildings the gains in summer can be reduced by sufficient sun protection devices placed outside the rooms in the ventilated space between the inner and outer facade. To evaluate the energetic performance, three buildings with double facade were monitored for at least one year (Siemens Building in Dortmund/Germany, Victoria Insurance Company in Duesseldorf/Germany and RWE Tower in Essen/Germany). The results document the indoor climate, the boundary conditions for further planning and the possibilities for high rise buildings without or with little cooling facilities.

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

A Study on Fire Features of Double-Skin Facade Structure by Using Fire Simulation (FDS) (화재 시뮬레이션(FDS)을 이용한 이중외피 구조의 화재 특성에 관한 연구)

  • Gu, Seon-Hwan;Kim, Hyun-Ho;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This study aims to address the fire characteristics of Double-skin facade using the Fire Dynamics Simulator (FDS). To end this, Double-skin facade was classified into the four structures, that is Box, Shaft-box, Corridor, Multistory, through PyroSim program which was based on FDS, and further each structure of fire characteristics were analyzed numerically as well as comparatively in the current study. This study also examined smoke movement, smoke density, smoke detectors, and visibility in order to closely identify the each structure of fire characteristics. The results of the study discovered that the Box structure did not significantly affect smoke which was rising in the other rooms, except for the fire room whereas the Corridor structure had positive effects on Double-skin facade horizontally. In addition, the Shaft-box structure showed the fastest vertical movement by means of the shaft, on the other hand, rising smoke influenced the other rooms as well. The Multistory structure along with rising smoke had a great impact on the other divided rooms in a vertical way.

Analysis for Fire Spread through Double Skin Facade System with FDS (화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰)

  • Huh, Yoon-Taek;Park, Chang-Bok;Sung, June-Shik;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.110-116
    • /
    • 2009
  • This study is related with fire risk assessment for fire and smoke spread of double skin facade system by use of FDS (Fire Dynamics Simulator) which is a computational fluid dynamics (CFD) model of fire-driven fluid flow. For the study, fire scenario is intended to evaluate the impact of a fire spread for glazed office building. The major purpose of this study is to analyze the fire risk depending on the width of between inner skin and outer skin and to present fire prevention method regarding double skin facade system. The result of analysis presents fire spread more vertically as intermediate space becomes narrow. It is anticipated that fire can spread upper 2 stories above the fire floor if intermediate space with not more than 1m width. Therefore, prevention of vertical fire spread is required.

A Study on the Performance of Blind type Double-Skin Facade System with PV modules (PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구)

  • Jo, Hye-Jin;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

Performance Assessment of Building Envelopes I: Double Skin Facade (외피 친환경 성능평가 I: 이중외피)

  • Kim, Deuk-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.77-82
    • /
    • 2009
  • Many countries have been interested in sustainable development of buildings for environmental preservation. Thus it is significant to assess building envelopes in terms of $CO_2$ emissions owing to Kyoto Protocol. In this paper, a Double Skin Facade(DSF) installed in a general office building was assessed by $CO_2$ emissions(one of the performance-based assessment). To predict $CO_2$ emissions caused by the building energy consumption, the dynamic simulation program(Energy Plus) and $CO_2$ emission factor was used. Because DSF has various airflow regimes, pre-simulation runs were conducted to decide proximate optimal airflow regimes depending on seasonal variation. It is shown that the DSF can achieve 17.1-36.5% of annual energy savings.

  • PDF

A Study on the Cavity Height of Muti-Story Double-Skin Facade for better Thermal Performance (열성능을 고려한 다층형 이중외피의 중공층 높이에 관한 연구)

  • Shin, Seon-Joon;Jo, Jae-Hun;Seok, Ho-Tae;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.53-62
    • /
    • 2005
  • In this study, the thermal performance of multi-story double-skin facade(DSF) with variation of cavity height is evaluated to offer useful data in determining cavity height of multi-story DSF. For this, thermal criteria for multi-story DSF is adopted and a DSF model for evaluation of the thermal performance is established. Through the evaluation of CFD simulation, the recommended height of multi-story DSF is 5 stories or less to improve the thermal performance during the intermediate season.

An Experimental Study on Thermal Breakage in Curtain Wall Glazing (커튼월 유리의 열파손에 관한 실험적 연구)

  • Lee, Jae-Hyun;Nam, Jung-Woo;Bang, Jung-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.236-237
    • /
    • 2013
  • In recent years, the use of glass applied to curtain wall as a building facade material has increased in our nation. However, the non-tempered curved double glass is very easy to broke because it is difficult to guarantee the quality in process of making it into double glazing. So, it is more vulnerable to thermal breakage than tempered double glass. In this paper, surface temperature difference on curved double glazing was compared to that of heat strengthened glass and flat glass by conducting thermal breakage experiments. As a result, flat single glass was broken at temperature difference of 100~140 degrees but curved double glazing was broken at that of 40~60 degrees. Therefore, it was concluded that curved double glazing is more vulnerable than flat double glazing to thermal breakage, and it should be considered the possibility of thermal breakage when curtain wall glazing is applied as a building facade material.

  • PDF