References
- S. J. Park, J. H. Jo, T. H. Ahn, M. S. Yeo, H. T. Seok and K. W. Kim, "A Study on the Application of the Double-Skin Facade to Apartment Buildings", Architectural Institute of Korea, Vol. 22, No. 1 pp. 453-456 (2002).
- K. W. Kim, "Overview of Recent Developments of Double-Skin Facade System", Journal of Architectural Institute of Korea, Vol. 47, No. 9, pp. 28-33 (2003).
- J. H. Lee, "A Box Window for the Control of Indoor Environment of Korean High-Rise Residential Complex", Yonsei University, Korea (2006).
- J. H. Cho, "A Study on Effective Application of Double Skin System for Energy Saving", Kon-Kuk University, Korea (2004).
- Y. B. Lee, "A Study on Decrease and Improvement Plan by Stack Effect in Skyscrapers", Ykong-Gi University, Korea (2008).
- J. S. Yoon, "Fire Analysis for High-rise Apatrment Building By Fire Simulation Program", Chungbuk National University, Korea (2010).
- Y. S. Sonh, S. K. Dan, B. W. Lee, S. P. Kwon, D. I. Shin and T. O. Kim, "Simulation of Heat and Smoke Behavior for Wood and Subway Fires by Fire Dynamics Simulator (FDS)", Journal of the Korean Institute of Gas, Vol. 14, No. 6, pp. 31-37 (2010).
- ThunderHead Eng, "PyroSim User Manual", The RJA Group Inc, Chicago, USA (2011).
- H. T. Seok, "Characteristics and Application of Double Skin Curtain Wall System", Journal of Architectural Institute of Korea, Vol. 47, No. 9, pp. 34-39 (2003).
- D. W. Kim and C. S. Park, "Energy Performance Assessment of a Double Skin System for Various Configurations", Journal of Architectural Institute of Korea, Vol. 26, No. 1, pp. 379-387 (2010).
- Y. B. Bae, S. H. Ryu, Y. I. Kim, S. K. Lee, O. H. Keum and S. K. Park, "Validation of FDS for the Pool Fires within Two Rooms", Journal of Korean Institute of Fire Science & Engineering, Vol. 24, No. 5, pp. 60-67 (2010).
- Y. T. Huh, C. B. Park, J. S. Sung and M. O. Yoon, "Analysis for Fire Spread through Double Skin Facade System with FDS", Journal of Korean Institute of Fire Science & Engineering, Vol. 23, No. 5, pp. 110-116 (2009).
- S. Y. Mun, J. H. Cho, C. H. Hwang and S. H. Park, "Sensitivity Analysis of Soot Yield on Fire Characteris tics in the Fire Modeling using FDS", Proceedings of 2012 Fall Annual Conference, Korean Institute of Fire Science & Engineering, pp. 573-576 (2012).
- K. H. Kim and C. H. Hwang, "Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling", Journal of Korean Institute of Fire Science & Engineering, Vol. 27, No. 4, pp. 27-34 (2013). https://doi.org/10.7731/KIFSE.2013.27.4.27
- G. P. Forney, "Smokeview User's Guide", Fire Research Division, Building and Fire Research Laboratory, NIST, USA (2007).
- K. McGrattan, R. McDerMott, S. Hostikka, J. Floyd. "Fire Dynamics Simulator (Version 5) User's Guide", NIST SP 1019-5, NIST, USA (2010).
- ThunderHead Eng, "PyroSim User Manual", The RJA Group Inc, Chicago, USA (2011).
- T. T. Lie, "Fire Protection Handbook", Applied Science Publishers Ltd., London, UK (1997).
- National Fire Service Academy, "Fire Protectiong Simulation", National Fire Service Academy, Korea (2009).
- National Fire Service Academy, "Fire Science", National Fire Service Academy, Korea (2009).
Cited by
- Applying analytic hierarchy process to the evaluation of double skin façades pp.1752-7589, 2018, https://doi.org/10.1080/17452007.2018.1515062