• Title/Summary/Keyword: Dosimetry

Search Result 760, Processing Time 0.024 seconds

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Development of Web-based Dosimetry Calibration Program for High Energy Radiation (웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발)

  • Shin Dong Oh;Shin Dong Ho;Kim Sung Hoon;Park Sung Yong;Seo Won Seop;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.116-124
    • /
    • 2005
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to uncertainty of the physical parameters used. Recently the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocol. In this work web-based dose calibration program for IAEA TRS-398 and AAPM TG-51 protocols were developed. This program developed using the Visual C$\#$ language can be used in the internet. User selectable dosimetry protocol on the web allows the absorbed dose to water data of the two protocols at a reference point to be easily compared, and enables to conveniently manage and understand the current status of the dosimetry calibration performed at participating institutions in korea. This program and the resultant database from the web-based calibration can be useful in developing new dosimetry protocols in Korea.

  • PDF

One Click Film (OCF) Dosimetry System for Routine QA (주기적 정도관리를 위한 One Click Film (OCF) 선량측정 시스템)

  • Kim So Young;Yi Byong Yong;Joo Kwan Sik;Kim Jong Heon;Ahn Seung Do;Lee Sang Wook;Choi Eun Kyoung
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.375-380
    • /
    • 2002
  • Purpose : To develop a practical film dosimetry system for routine Quality Assurance (QA). Materials and Methods :An One Click Film (OCF) Dosimetry system was designed to perform swift routine QA with functions including automatic fog value elimination, angle adjustment, automatic symmetry calculation, and realtime profile generation with the ability to display realtime three-dimensional dose distributions. Results : The most frequently used functions for routine QA, such as the elimination of the fog value, conversion into an H&D curve, symmetry, and isodose distribution, can be achieved with only one click. Conclusion : Reliable results were achieved with the OCF dosimetry with simpler steps than other commercially available film dosimetry systems for routine QA. More research on the refined user interface will make this system be clinically useful.

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

Electric Field Effect on Numerical Dosimetry for Wireless Power Transfer System (무선전력전송의 조사량 평가 시 전기장 영향)

  • Park, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.499-505
    • /
    • 2015
  • The coupling effect of electric fields incident on the biological object is investigated in regards to dosimetry for a wireless power transfer(WPT) system using electromagnetic resonance phenomenon. The internal electric fields induced a biological sphere model exposed to a magnetic dipole are calculated with the finite-difference time-domain(FDTD) method considering both incident electric and magnetic fields, the impedance method considering only incident magnetic fields, and theoretical analysis. The results represent that the electric coupling effect on a biological object nearby the WPT system should be considered to conduct exact dosimetry.

Trends and Issues in Metabolism and Dosimetry for Tritium Intake (삼중수소 피폭방사선량 평가의 경향과 이슈에 대한 고찰)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Tritium is the one of the most important radionuclide for workers in nuclear power plants (NPPs) and the public, from the dosimetric point of view. Humans are likely to have internal radiation exposure by tritium inhalation. Radiation exposure by tritium accounts for approximately 7% and 60~90% of the total radiation exposure of NPP workers and the public during normal operation, respectively. Thus, many researches have been conducted to estimate the internal dose by tritium precisely in the world. In terms of tritium dosimetry, this paper provides the current status of research for tritium metabolism and dosimetry.

Energy Response in Chemiluminescence Dosimetry with Sugar and Sorbite

  • Jun, J.S.;Guggenberger, R.;Dalheimer, A.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.626-637
    • /
    • 2001
  • A series of study on energy dependence in chemiluminescence dosimetry with sugar and sorbite produced in two different countries was carried out administering a dose of 5 Gy to the samples at six different mean photon energies of 30, 50, 80, 130, 662 and 1250 keV. The results revealed distinct energy dependence of chemiluminescence(CL) output of sugar and sorbite. Although the energy dependence, in general, could be fitted by a polynomial of (os E, with I being radiation energy, up to cubic term, we reached a conclusion that the adoption of a fitting function, $y_{R}$$^{=a}$.(1-e $^{-b.logE}$)$^{c}$ +d, deduced from theoretical energy response curve calculated as the ratio of the mass energy absorption of the samples of interest to the soft tissue is more reasonable and rational. Herecoefficients $y_{R}$ is CL intensity, and a, b, c and d are constants to be determined in the fitting process. Energy dependence of relative sensitivities of one sample to the other, discrepancy in sensitivities of the samples from the two countries, and prominent grain size effect in Sorbitol were also shown.shown.

  • PDF

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.