• 제목/요약/키워드: Dose optimization

검색결과 238건 처리시간 0.035초

인공신경망 모형을 이용한 급속혼화공정에서 적정 응집제 주입농도 결정 및 응집처리후 탁도의 예측 (Prediction of Turbidity in Treated Water and the Estimation of the Optimum Feed Concentration of Coagulants in Rapid Mixing Process using an Artificial Neural Network Model)

  • 정동환;박규홍
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.21-28
    • /
    • 2005
  • The training and prediction modeling using an artificial neural network was implemented to predict the turbidity of treated water as well as to estimate the optimized feed concentration of polyaluminium chloride (PACl) in a water treatment plant. The parameters used in the input layers were pH, temperature, turbidity and alkalinity, while those in output layers were PACl and turbidity of treated water. Levenberg-Marquadt method of feedforward back-propagation perceptron in the neural network toolbox of MATLAB program was used in this study. Correlation coefficients of the training data with the measured data were 0.9997 for PACl and 0.6850 for turbidity and those of the testing data with measured data were 0.9140 for PACl and 0.3828 for turbidity, when four parameters at input layer, 12-12 nodes each at both the first and the second hidden layers, and two parameters(PACl and turbidity) at output layer were used. Although the predictability of PACl was improved, compared to that of the previous studies to use the only coagulant dose as output layer, turbidity in treated water could not be predicted well. Acquisition of more data through several years obtained with the advanced on-line measuring system could make the artificial neural network useful and practical in actual water treatment plants.

Simulation of 4H-SiC MESFET for High Power and High Frequency Response

  • Chattopadhyay, S.N.;Pandey, P.;Overton, C.B.;Krishnamoorthy, S.;Leong, S.K.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권3호
    • /
    • pp.251-263
    • /
    • 2008
  • In this paper, we report an analytical modeling and 2-D Synopsys Sentaurus TCAD simulation of ion implanted silicon carbide MESFETs. The model has been developed to obtain the threshold voltage, drain-source current, intrinsic parameters such as, gate capacitance, drain-source resistance and transconductance considering different fabrication parameters such as ion dose, ion energy, ion range and annealing effect parameters. The model is useful in determining the ion implantation fabrication parameters from the optimization of the active implanted channel thickness for different ion doses resulting in the desired pinch off voltage needed for high drain current and high breakdown voltage. The drain current of approximately 10 A obtained from the analytical model agrees well with that of the Synopsys Sentaurus TCAD simulation and the breakdown voltage approximately 85 V obtained from the TCAD simulation agrees well with published experimental results. The gate-to-source capacitance and gate-to-drain capacitance, drain-source resistance and trans-conductance were studied to understand the device frequency response. Cut off and maximum frequencies of approximately 10 GHz and 29 GHz respectively were obtained from Sentaurus TCAD and verified by the Smith's chart.

공존이환(Comorbidity)이 있는 암환자에서의 항암약물치료 (Chemotherapy in Cancer Patients with Comorbidity)

  • 문용화;정희철
    • Journal of Gastric Cancer
    • /
    • 제4권2호
    • /
    • pp.59-74
    • /
    • 2004
  • This report attempts to explain the (i) implications of comorbidity for research and practice in the fieldo of oncology, (ii) the approach for dosing of anti-cancer drugs in the presence of comorbidity, as an example of its clinical application, and finally (iii) the dosing guidelines for the anticancer drugs clinically active in gastric cancer in the presence of renal or liver dysfunction. This has resulted from the idea of approaching comorbidity in a systematic way and of integrating it with oncologic decisions. Various methods have been used to assess comorbidity. However, significant work remains to be done to analyze how various diseases combine to influence the oncologic outcome. The main end-point explored so far has been mortality, but a largely open challenge remains to correlate comorbidity with treatment tolerance and functional and quality of life, as well as to integrate it in clinical decision-making. Cancer chemotherapy in comorbidity should be considered as an example of the need for dose optimization in individual patients, and it should be determined by considering the basic principles of the pharmacokinetics and the pharmacodynamics of the agents. This review analyzes the available data on the pharmacokinetics and the toxicities of anti-cancer agents in the comorbidity population.

  • PDF

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

개선된 다운힐 심플렉스 법을 이용한 주파수 영역에서의 뇌자도 신호원 추정 (Magnetoencephalography Source Localization using Improved Downhill Simplex Method in Frequency Domain)

  • 김병준;안광옥;이찬희;정현교
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.231-238
    • /
    • 2008
  • Nelder-Mead downhill simplex method (DSM), a kind of deterministic optimization algorithms, has been used extensively for magnetoencephalography(MEG) dipolar source localization problems because it dose not require any functional differentiation. Like many other deterministic algorithms, however, it is very sensitive to the choice of initial positions and it can be easily trapped in local optima when being applied to complex inverse problems with multiple simultaneous sources. In this paper, some modifications have been made to make up for DSM's limitations and improve the accuracy of DSM. First of all, initial point determination method for DSM using magnetic fields on the sensor surface was proposed. Secondly, Univariant-DSM combined DSM with univariant method was proposed. To verify the performance of the proposed method, it was applied to simulated MEG data and practical MEG measurements.

Influence of Coating Ligands onf Enzyme-linked Immunosorbent Assay of Toluene

  • 김소영;이남택;최명자
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권9호
    • /
    • pp.953-957
    • /
    • 2001
  • The specificity of conjugation site for coating ligands was investigated using toluene-bovine serum albumin (BSA) conjugates in which BSA was conjugated at the position of o-, m-, and ${\rho}-toluic$ acid. Toluene-BSA conjugated at ${\rho}-position$ showed a binding activity of about 89-95%, whereas, those conjugated at o- and m-position of toluene exhibited a binding activity of 5 and 11%, respectively. On the basis of the above result, coating ligands with various proteins (OVA, BSA, KLH) were compared by conjugating with $\rho-toluic$ acid, and toluene-KLH was considered as the best coating ligand for this ELISA. Indirect competitive ELISA method was developed using anti-toluene antibody and $\rho-position$ conjugated toluene-KLH. The dose-response curve constructed after kinetic and optimization studies showed a 1${\times}$10-4 - 1${\times}$102 mM detectable response range with 0.1 ${\mu}M$ detectability. In specificity test of the antibody, the binding capabilities of aromatic compounds substituted with nitro-, alkyl-, chloro-, and hydroxyl group were larger rather than those of aromatic compounds (benzene, toluene and xylene) themselves. Also, tests with soil and water samples that had been spiked with toluene resulted in 102.7-113.7% recovery.

Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors

  • Noushinmehr, R.;Moussavi zarandi, A.;Hassanzadeh, M.;Payervand, F.
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.293-302
    • /
    • 2019
  • Many researches have been done to develop and improve the performance of personal (individual) dosimeter response to cover a wide of neutron energy range (from thermal to fast). Depending on the individual category of the dosimeter, the semiconductor sensor has been used to simplify and lightweight. In this plan, it's very important to have a fairly accurate counting of doses rate in different energies. With a general design and single-sensor simulations, all optimal thicknesses have been extracted. The performance of the simulation scheme has been compared with the commercial and laboratory samples in the world. Due to the deviation of all dosimeters with a flat energy response, in this paper, has been used an idea of one semi-conductor sensor to have the flat energy-response in the entire neutron energy range. Finally, by analyzing of the sensors data as arrays for the first time, we have reached a nearly flat and acceptable energy-response. Also a comparison has been made between Lucite-PMMA ($H_5C_5O_2$) and polyethylene-PE ($CH_2$) as a radiator and $B_4C$ has been studied as absorbent. Moreover, in this paper, the effect of gamma dose in the dosimeter has been investigated and shown around the standard has not been exceeded.

우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량 (Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea)

  • 이광용;이병영;이정은;이현구;정승환;김병우;김혁주;김동섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.401-410
    • /
    • 2009
  • 목 적 : 골반 및 요추 엑스선검사는 진단 엑스선검사 중 생식선을 포함하고 있고 환자가 받는 방사선량이 많은 검사로서 우리나라에는 골반 및 요추 엑스선검사에서의 환자선량 권고량이 마련되어 있지 않다. 따라서 국내 의료기관에서의 골반 및 요추 엑스선검사 시 환자가 받는 방사선량을 측정 평가하고 골반 및 요추 엑스선검사에서 환자의 방사선 방어 최적화를 위한 환자선량 권고량을 확립한다. 방 법 : 전국 125개 의료기관에서 골반 전후면 촬영, 요추 전후면 및 측면 촬영시 촬영조건과 진단영상정보를 조사 분석하고 환자가 받는 입사표면선량을 유리선량계를 사용하여 측정 평가한다. 환자가 받는 방사선량 중 제3사분위값에 해당하는 선량값을 의료기관에 권고할 골반 및 요추 엑스선검사에서의 환자선량 권고량으로 확립한다. 결 과 : 전국 125개 의료기관에서 골반 및 요추 엑스선검사 시 진단영상정보를 조사하고 환자가 받는 입사 표면선량을 측정한 결과 골반 전후면 엑스선검사에서는 관전압이 60~97 kVp, 평균 75 kVp를 사용하였고, 관전류-시간곱(mAs)는 8~123 mAs, 평균 29.7 mAs를 사용하였다. 요추 전후면 및 측면 엑스선검사에서는 관전압을 각각 65~100 kVp, 평균 78 kVp와 70~109 kVp, 평균 87 kVp를 사용하였고, mAs도 각각 10~100 mAs, 평균 35.2 mAs와 8.9~300 mAs, 평균 64.1 mAs를 사용하였다. 골반 및 요추 엑스선검사에서의 환자가 받는 입사표면선량을 측정한 결과, 골반 전후면 엑스선검사에서는 최소값 0.59 mGy, 최대값 12.69 mGy, 평균값 2.88mGy이었으며, 제1사분위값은 1.91 mGy, 중앙값은 2.67 mGy, 제3사분위값은 3.42 mGy이었다. 요추 전후면 엑스선검사에서는 최소값 0.64 mGy, 최대값 23.84 mGy, 평균값 3.68 mGy이었으며, 제1사분위값은 2.41 mGy, 중앙값은 3.40 mGy, 제3사분위값은 4.08 mGy이었다. 요추 측면 엑스선검사에서는 최소값 1.90 mGy, 최대값 45.42 mGy, 평균값 10.08 mGy이었으며, 제1사분위값은 6.03 mGy, 중앙값은 9.09 mGy, 제3사분위값은 12.65 mGy이었다. 결 론 : 우리나라의 의료기관에서 골반 전후면 엑스선검사에서 의료기관에 권고할 환자선량 권고량은 3.42 mGy, 요추 전후면 엑스선검사에서는 4.08 mGy, 요추 측면촬영에서는 12.65 mGy로 세계보건기구 등 6개 국제기구가 공동으로 권고한 골반 전후면 검사 10 mGy, 요추 전후면 검사 10 mGy 및 요추 측면 검사 30 mGy 보다는 낮았다.

  • PDF

근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석 (The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom)

  • 허현도;김성훈;조삼주;이석;신동오;권수일;김헌정;김우철;노준규
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.223-229
    • /
    • 2005
  • 목적: 근접방사선 치료시 직장내 선량측정은 치료간(Inter-fraction) 직장의 형태가 변화하므로 측정의 재현성을 이룰 수 없다. 본 연구에서는 근접방사선치료용 다목적 팬톰(Multi Purpose Brachytherapy Phantom, MPBP)을 제작하여 치료 시와 동일한 조건을 재현하였고 이때 측정한 선량 값을 직장의 부작용을 줄이기 위해 선량최적화에 적용하고자 하였다. 대상 및 방법: 자궁경부암 근접방사선 치료 시 탄뎀(tandem)과 난형체(ovoid)를 사용한 환자 4명을 대상으로 다이오드 검출기를 이용하여 직장표시 기준점 R1에서 선량측정을 시행하였다. 환자 당 5회씩 총 20회 직장선량을 측정하였다. 그리고 반복 측정 시 다이오드 검출기의 설정 변화(set up variation)를 분석하였다. 그리고 자체 제작된 근접방사선치료용 다목적 팬톰에서 MFA (Multi Function Applicator)를 이용하여 치료 시와 동일한 조건을 재현한 후 열형광선량계(TLD)를 이용하여 직장 표시 기준점 좌표 위치에서 선량을 측정하였다. 결과: 직장 내 다이오드 검출기의 측정 결과 설정 변화는 환자 1의 경우에 Y방향에서 최고 $11.25{\pm}0.95mm$보였고, 환자 2와 3은 Z 방향에서 각각 $9.90{\pm}4.50mm$$20.85{\pm}4.50mm$를 나타냈다. 그리고 환자 4는 Z 방향에서 $19.15{\pm}3.33mm$의 변화를 나타내었다. 또한 다이오드 검출기 위치에 따른 평균선량 값은 $122.82{\pm}7.96cGy{\sim}323.78{\pm}11.16cGy$로 나타났다. MPBP에서 TLD의 측정 결과는 직장 표시 기준점(R1)에서 환자1과 4는 상대오차가 각각 최고 8.6%와 7.7%를 보였고, 환자2와 3은 각각 1.7%와 1.2%의 오차를 보였다. 그리고 R과 R2에서 측정한 선량 값들은 환자 2의 R 지점을 제외하고 계산값과 비교하여 $1.7{\sim}8.6%$ 높은 값을 나타냈다. 그리고 반복측정으로 인한 위치변화와 그에 따른 선량 값의 변화는 분석하지 않았다. 계산 값과 측정값의 상대오차가 미국의학물리학회 보고서에서 권고한 15% 내에서 잘 일치하는 것으로 분석되었다. 결론: 자체 제작된 근접치료용 다목적 팬톰(MPBP)은 치료 시와 동일한 조건에서 선량측정의 재현성을 이룰 수 있었고, 직장의 기준점에서 선량을 정확히 분석할 수 있었다. 또한 팬톰에서 측정한 데이터를 이용하여 직장의 부작용을 줄이기 위해 치료 전 선량 최적화를 이루는데 충분한 자료로 활용할 수 있다고 판단되었다.

일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가 (Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield)

  • 김승욱;안병주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.895-908
    • /
    • 2018
  • 의료방사선의 관리에서 가장 중요한 사항은 진료의 적정성을 확보하면서 방사선위해를 최소화하는 것이다. 국제원자력기구는 진단방사선 분야의 선량 감소 방법에 대한 지침서를 만들어 환자피폭선량을 측정하여 각 국가에 사용하도록 권고하고 있다. 또한 국내에서도 우리나라의 실정에 맞게 각 촬영마다 환자 피폭 선량값을 연구하여 진단참고준위를 제시하였다.환자가 질병 때문에 방사선 진료를 받는 것은 방사선 때문에 일어날 수 있는 위해보다 그것으로 얻어지는 이익이 크기 때문이다. 병실 이동검사와 같이 자신의 질병과 무관하게 방사선에 노출되는 환자 및 보호자들의 피폭을 줄이기 위해서는 환자, 방사선사, 의사 및 의료기관의 노력이 가장 중요하다.이에 본 연구에서는 개선방안의 일환으로 MG로 병실의 이동 검사에 대한 문제점을 제시하고 이 문제점을 근거로 하여 산란선으로 예상되는 공간선량률을 분석하였다. MG에 자체 개발한 방어벽을 설치하여 방어벽 설치 전후의 공간선량률을 측정하여 그 감소율을 분석하였다. 최종적으로 이 자료들을 종합하여 MG에 방어벽을 부착하여 방사선사의 병실이동에 대한 부담감의 최소화, 병실 이동검사로 인한 방사선사, 환자 및 보호자를 방사선 노출로부터 보호하고, 검사로 인한 주위 환자 및 보호자의 불편을 최소화하는데 의의가 있다. 이와 같은 개선안에 대해 보다 효율적인 시행을 위하여 MG에 대한 새로운 법 제도가 마련되면, 향후 예상되는 비용, 인력, 고객만족도 및 더욱 더 안정적인 피폭감소방안이 정착될 것이라 사료된다.