• Title/Summary/Keyword: Dose coefficients

검색결과 151건 처리시간 0.024초

방사선 조사된 조개류의 확인을 위한 ESR Spectroscopy의 이용 (ESR Spectroscopy for Detecting Gamma-Irradiated Shellfishes)

  • 남혜선;양재승
    • 한국식품영양과학회지
    • /
    • 제30권1호
    • /
    • pp.43-47
    • /
    • 2001
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals after 9 weeks of storage in order to detect irradiated shellfishes. The irradiated shellfishes (short-necked clam, purplish washington clam, freshwater clam, jackknifed clam, scallop and hard-shell mussel) presented an asymmetric absorption in shape at $g_{1}$=2.002~2.003 and $g_{2}$=1.998. The strength of the ESR signal increased linearly with the applied doses (1~7 kGy). A highly positive correlation coefficients ($R^{2}$=0.9136~0.9896) were obtained between the irradiation dose and corresponding ESR signal intensity. The intensity of the signals after irradiation was stable even after 9 weeks of storage at 5$\pm$1$^{\circ}C$.

  • PDF

Development of a reference framework to assess stylized human intrusion scenarios using GENII Version 2 considering design features of planned near-surface disposal facility in Korea

  • Kwon, Ki Nam;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1561-1574
    • /
    • 2019
  • A standard form of six stylized human intrusion scenarios for a near-surface disposal facility (e.g. the planned Korean repository, Gyeongju Phase II) is proposed through re-categorization of totally thirty-one past cases reported in public literature. A reference assessment framework for inadvertent human intrusion is newly developed using GENII Version 2 conforming to the ICRP Publication 60 and thereafter. Calculated dose from the assessment framework is verified by comparing with hand calculation results for simplified model equations independently derived. Results from GENII Version 2 and 1.485 show inevitable differences, which is mainly attributed to the difference in the external dose assessment model. If intake dose coefficients in GENII Version 1.485 are modified, the difference can be reduced but still exist to an extent. Through deterministic and probabilistic sensitivity analysis, most affecting four parameters are derived and uncertainties of the parameters are quantified. It is expected that the reference assessment framework together with representative stylized scenarios can be used to do a human intrusion impact assessment for a specific repository using site-specific information. Especially, the past practice of human intrusion impact assessment using GENII Version 1.485 with or without modification may be replaced with the new assessment framework developed in this study.

$^{14}C$-radiolabeled MIB와 HSDM을 이용한 최적 PAC 투입량 예측프로그램의 개발 (Development of Optimum PAC Dose Prediction Program using $^{14}C$-radiolabled MIB and HSDM)

  • 김영일;배병욱;김규형;홍현수
    • 대한환경공학회지
    • /
    • 제27권10호
    • /
    • pp.1123-1128
    • /
    • 2005
  • 흙냄새 혹은 곰팡이 냄새 등을 야기시키는 MIB는 남조류나 방선균등에 의해 생성되는 2차 대사산물이다. MIB는 일반적인 정수공정(응집, 침전, 여과)에 의해서는 쉽게 제거가 되지 않을 뿐만 아니라, 수돗물에 수 ng/L정도만 존재하더라도 소비자에게 심미적인 불쾌감을 유발시킬 수 있다. 일반적으로 MIB는 정확한 양의 PAC가 투입될 때 효과적으로 제거될 수 있으나, 대부분 정수장 운전자들은 PAC를 적당히 투입한 다음 처리 후 직접적인 관찰(냄새감지)에 근거하여 투입량을 조절함으로써 과잉투입 혹은 과소투입과 같은 결과를 야기하고 있는 실정이다. 이와 같은 배경을 바탕으로 본 연구에서는 $^{14}C$-radiolabled MIB을 이용한 등온흡착 및 흡착동역학 실험을 수행하여 HSDM에 필요한 물질전달계수와 표면확산계수를 결정하였다. HSDM은 실제 실험을 잘 모의하였으며, 실험 결과 또한 정확히 예측하였다. HSDM 결과에 근거하여 저자들은 Excel spreadsheet을 이용하여 최적 PAC 투입량 예측프로그램을 개발하였다. 개발된 프로그램을 실제 2개의 정수장에 적용한 결과 정수장 운전자의 경험에 의해 구해진 실제 PAC 투입량과 새롭게 개발된 프로그램에 의해 구해진 PAC 투입량 사이에 많은 차이를 보였다. 만약 정수장 운전자가 최적 PAC 투입량 예측프로그램을 이용하여 PAC 투입량을 결정한다면, 이 문제는 충분히 해결될 수 있을 것으로 판단된다.

고온 및 방사선이 중성자 차폐재의 열적, 역학적 및 차폐능 특성에 미치는 영향 (Effects of High Temperature and Radiation on the Properties of Thermal, mechanical and Shielding Ability of Neutron Shielding Materials)

  • 조수행;홍순석;정명수;도재범;박현수
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.404-408
    • /
    • 1999
  • Effects of heating time and radiation under high temperature on the properties of thermal, mechanical and shielding ability of modified (KNS-101), hydrogenated bisphenol-A(KNS-201) type epoxy resin and phenol-novolac(KNS-301) type epoxy resin based neutron shielding materials that are used for shipping casks for radioactive material have been investigated. At early stages, the offset temperatures of KNS-101, KNS-201 and KNS-301 increased with the heating time under high temperature, but it was rarely affected by the heating time in the later stages. In addition, the thermal conductivities of KNS-101 and KNS-201 decreased with heating time, but that of KNS-301 increased with the heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials decreased with heating time. On the contrary, the thermal expansion coefficients of neutron shielding materials decreased with heating time. At the high temperature, the tensile strength and flexural strength of the shielding materials of KNS-101 and KNS-301 increased with heating time, but those of KNS-201 decreased with heating time. The shielding ability of neutron shielding materials slightly increased with the radiation dose, and shielding abilities of shielding materials of KNS-101 and KNS-201 were affected to a more extent than that of KNS-301 by radiation dose under high temperature.

  • PDF

식품의약품안전청의 치료방사선 선량보증과 측정불확도 (KFDA TLD Dose Quality Audit and Measurement Uncertainty)

  • 정희교;이현구;김귀야;양현규;임천일
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.153-156
    • /
    • 2004
  • 식품의약품안전청은 1978년 12월 방사선 분야의 국가교정검사기관으로 지정되어 현재까지 Co-60선원을 이용 치료준위 방사선측정기에 대한 교정을 수행하고 있다. 식약청의 에어커마와 물 흡수선량 측정값은 국제도량형국(BIPM)과 측정소급성을 유지하고 있으며, 교정계수의 확장불확도는 0.9 %(k=2)이다. 식약청에서는 외부방사선에 대한 선량보증의 일환으로 1999년 전리함을 이용하여 방사선치료기관의 선량측정을 수행하였으며, 2002년부터 열형광선량계(TLD)를 이용한 선량측정체계를 확립 ${\cdot}$ 운영하고 있다. TLD 판독에 대한 측정불확도는 1.6 %(k=1)이며, 측정불확도를 감안하여 선량보증의 허용한계를 ${\pm}$ 5 %로 설정하였다. TLD 판독값을 선량으로 전환하는 과정에서 선질, 비선형성, 홀더사용 등의 영향을 보정하기 위한 보정정수를 사용하였다. 2003년도 치료방사선 선량보증사업에는 53개 기관(71개 선질)이 참여하였다. 선량보증 결과 71개 선질 중63개 선질(89 %)이 1차 측정에서 허용한계를 만족하였다. 허용한계 초과기관에 대해서는 재측정을 수행하였고, 그 결과 모두 허용한계 이내의 값을 나타냄을 확인하였다.

  • PDF

개질 에폭시수지 및 수소 첨가된 비스페놀-A형 에폭시수지계 차폐재의 열적 및 역학적 성질에 미치는 방사선 영향 (Effects of Radiation on Thermal and Mechanical Properties of Modified Epoxy Resin and Hydrogenated Bisphenol-A Type Epoxy Resin Based Shielding Materials)

  • 조수행;홍순석;김익수;도재범;노성기
    • 공업화학
    • /
    • 제8권3호
    • /
    • pp.524-532
    • /
    • 1997
  • 방사성물질의 수송 및 저장용기 등에 사용하기 위하여 개발한 개질 에폭시수지 및 수소 첨가된 비스페놀-A형 에폭시수지계 중성자 차폐재들의 열분해온도, 열전도도, 열팽창 등의 열적 성질 및 인장강도, 압축강도, 굴곡강도, 비중, 무게변화, 수소 함량변화 등의 역학적 성질에 방사선이 미치는 영향을 검토하였다. 방사선 조사선량의 증가에 따라 KNS(Kaeri Neutron Shield)-201과 KNS-302 차폐재들의 열분해온도는 증가하는 경향을 나타내었으나, KNS-202와 KNS-301은 0.5 MGy 이상에서는 감소하는 경향을 나타내었다. 또한 방사선 조사선량이 온도에 따른 차폐재들의 무게변화에는 거의 영향을 미치지 않는 것으로 나타났다. 0.1 MGy까지 열전도도는 방사선 조사선량의 영향을 거의 받지 않는 것으로 나타났다. 또한 KNS-301과 302 차폐재들의 열팽창은 KNS-201과 202보다 방사선 영향을 적게 받는 것으로 나타났다. 0.1 MGy까지는 방사선 조사선량의 증가에 따라 KNS-202 및 KNS-301과 302차폐재들의 인장, 압축 및 굴곡강도는 증가하는 경향을 나타내었다. 반면에 KNS-201은 방사선 조사선량의 증가에 따라 감소하는 경향을 나타내었다. 또한 조사선량의 증가에 따른 차폐재들의 비중, 무게 및 수소함량은 크게 변하지 않는 것으로 나타났다.

  • PDF

Artificial Insemination with Low-Dose Semen does not affect Swine Reproductive Performances

  • Chung, Ki-Hwa;Lee, Il-Joo;Sa, Soo-Jin;Kim, In-Cheul;Jung, Byeong-Yeal;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • 제37권4호
    • /
    • pp.263-267
    • /
    • 2013
  • Pig producers have been shown keen interest of the number of spermatozoa in a semen dose since pig artificial insemination introduce. However, determining the minimal number of spermatozoa need per AI without detrimental effect on overall reproductive performances is not an easy question to answer. To increase the efficiency of semen utilization in pig AI, optimum number of spermatozoa per dose needed to determine. The objective of this study was to determine the reproductive performance and factors that affect on-farm application of low-dose semen insemination in sows. Data were collected from Darby Genetics AI studs from 4th of June to 7th of July, 2012 (n=401). The numbers of parturition were 84, 234 and 83 in sows inseminated with doses of $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ spermatozoa in 100ml extender, respectively. There were no significant differences on reproductive performances such as gestation period, total born, total born alive, stillbirth and mummy in sows inseminated with different semen doses. The average number of born alive was 10.5, 11.0 and 10.4 from sows inseminated with $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ sperms, respectively. Also, number of spermatozoa per dose did not affect litter size (p>0.10). There were no significant differences of maternal genetic line difference on gestation period, total number born, number born alive, born dead and mummy. The estimated correlation coefficients of the different semen doses with total number born, number born alive, born dead and mummy were r=-0.00, -0.01, 0.02 and 0.02, respectively. Taken together, the result of this study suggested that when semen was appropriately inseminated after induced ovulation, insemination with low-dose ($1.5{\sim}2.0{\times}10^9$) semen dose not adversely affect sow's fertility.

폐감귤박으로 만든 활성탄을 이용한 염료 Eosin Y 흡착에서 반응표면 모델링 (Response Surface Modeling for the Adsorption of Dye Eosin Y by Activated Carbon Prepared from Waste Citrus Peel)

  • 감상규;이민규
    • 공업화학
    • /
    • 제29권3호
    • /
    • pp.270-277
    • /
    • 2018
  • 반응 표면법(RSM)과 Box-Behnken 설계(BBD) 통계 방법을 사용하여 폐감귤박으로 만든 활성탄(WCAC)에 의한 염료 Eosin Y의 흡착을 검토하였다. 실험은 Eosin Y의 농도(Conc. : 30~50 mg/L), 용액 온도(Temp. : 293~313 K) 및 흡착제 투여량(Dose : 0.05~0.150 g/L)의 3가지 입력 변수를 가진 BBD에 따라 수행하였다. 염료 Eosin Y 제거에 대해 얻어진 2차 다항식 모델의 회귀분석 결정계수($R^2$) 값이 0.9851이고 적합성 결여(Lack of fit)의 p 값은 0.342로 실험 데이터는 2차 다항식 모델에 잘 부합하였다. 염료 농도 50 mg/L, 온도 333 K 및 흡착제 투여량 0.1056 g에서 최적 염료 흡착량 59.3 mg/g이 얻어졌다. WCAC에 의한 Eosin Y의 흡착공정은 유사 2차 속도식에 의해 잘 기술되었으며, 등온 실험결과는 Langmuir 모델식을 따랐다.

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.