• 제목/요약/키워드: Doppler phantom

검색결과 16건 처리시간 0.029초

Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구 (Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study)

  • 김영호;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구 (Study of Doppler Fluid Effects of Carbonated Water in a Bi-directional Flow Phantom Model)

  • 김지혜;허영철
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.83-91
    • /
    • 2024
  • 본 연구에서는 양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과를 확인하고자 하였다. 양방향 흐름 팬텀 모델은 동맥과 정맥의 흐름을 구현한 것이며 이중 수조 구조를 통해 유체의 순환이 가능하고 팬텀의 크기를 줄일 수 있게 고안되었다. 사용된 유체는 탄산수, 소금물, 설탕물, 증류수를 이용하였고 수조 표면에서 깊이 1.5 cm, 3.0 cm에서 초음파 B-mode와 컬러 도플러 효과를 이용해 초음파 스캔하였다. 컬러 도플러 효과는 탄산수, 소금물, 설탕물, 증류수 모두 도플러 시프트 효과를 나타냈으나 탄산수의 도플러 시프트 효과가 가장 높았고 깊이에 따른 변화에서도 탄산수의 도플러 시프트 효과 편차가 가장 적었다. 결론적으로 탄산수의 도플러 유체 사용 가능성을 확인할 수 있었고 탄산수의 기포가 적혈구의 도플러 반사체 역할을 하고 있음을 확인하였다. 따라서 도플러 초음파 팬텀 제작에서 혈액 모방액과 유사한 물질로 탄산수를 이용한 추가 연구가 필요하며 이에 본 연구가 기초자료를 제공할 것이라 사료 된다.

혈관협착팬텀의 제작 및 파워도플러의 영상 평가 (Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler)

  • 박희영;배종림;김정구
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.732-739
    • /
    • 2009
  • 혈관협착의 혈류 정보와 초음파 진단장비의 품질보증을 위한 혈관협착 팬텀을 자동 주입기를 이용하여 제작하였다. 혈관협착의 진단에 효율성이 높은 파워 도플러를 이용하여 제작된 혈관 협착 팬텀의 유용성을 조사하고, 초음파 영상 파라메타에 따른 혈관협착의 정도를 확인하였다. 혈관 협착 팬텀은 직경이 각각 8mm와 2.4mm인 실리콘 튜브로 혈관협착이 70%가 되도록 제작하였으며, 인체 조직과 유사한 음향 특성을 가지고 있는 젤라틴을 이용하여 실리콘 튜브를 감싸 주었다. 평면형 탐촉자를 이용하여 측정하였을 때 정상 혈관의 직경은 대체적으로 감소되어 측정 되었으며, 협착 혈관의 직경은 증가되어 측정되었다. 이득이 60% 이상, PRF가 3000Hz 이상, 필터가 max와 같은 급격한 변화를 제외하고는 각각의 파라메타에 크게 영향을 받지 않았으며, 각도에는 영향을 받지 않는 것으로 나타났다. 또한 곡면형 탐촉자를 이용할 경우 이득, PRF, 필터, 각도등에 영향을 받는 것으로 나타났다. 본 연구에서 제작된 자동주입기를 이용한 혈관 협착 팬텀은 혈관 협착 진단의 품질보증에 유용하게 이용될 수 있을 것으로 기대된다.

공명현상을 이용한 유방조직 팬텀의 석회화 관찰 (Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance)

  • 하명진;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.61-69
    • /
    • 2008
  • 유방초음파 검사는 유방암 검사에 있어 유방촬영술에 비하여 많은 장점이 있으나, 미세석회화 발견에는 적합하지 않은 단점이 있다. 이에 유방초음파 검사에서 기존의 7.5 MHz 선형 탐촉자를 사용하여 매질의 공명현상을 이용한 유방조직 석회화 병변을 관측할 수 있는 방법을 연구하였다. 먼저 gelatin과 돼지 젖가슴살을 이용하여 유방조직 팬텀을 제작하였으며, 외부 진동을 변화시켜 가며 석회화 병변을 관측하였다. 유방조직 팬텀안에 주입된 석회화는 주변 조직과 다른 공명을 일으키면서 외부진동에 따라 음향공명의 정도가 파워도플러의 ROI 영역 내의 색상의 밝기와 영역의 차이로 나타내었다. 낮은 주파수 영역에는 음향공명이 거의 나타나지 않았으며, 약 $300{\sim}400\;Hz$ 사이에서 일정한 플래토우 영역을 나타내었으며, 이후 주파수가 증가함에 따라 색상이 사라짐을 확인하였다.

  • PDF

공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단 (Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler)

  • 김정구;하명진
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.80-86
    • /
    • 2008
  • 유방초음파 검사는 유방암 검사에 있어 유방촬영술에 비하여 많은 장점이 있으나, 미세석회화 발견에는 적합하지 않은 단점이 있다. 이에 유방초음파 검사에서 기존의 7.5 MHz 선형 탐촉자를 사용하여 파워도플러와 매질의 공명현상을 이용한 유방조직 석회화 병변을 관측할 수 있는 방법을 연구하였다. 먼저 gelatin을 이용하여 유방조직 팬텀을 제작하였으며, 외부 진동을 변화시켜 가며 석회화 병변을 관측하였다. 유방조직 팬텀 안에 주입된 석회화는 주변 조직과 다른 공명을 일으키면서 외부진동에 따라 음향공명의 정도가 파워도플러의 ROI 영역 내의 색상의 밝기와 영역의 차이로 나타내었다. 낮은 주파수 영역에는 음향공명이 거의 나타나지 않았으며, 약 $300{\sim}600\;Hz$ 사이에서 일정한 플래토우 영역을 나타내었으며, 이후 주파수가 증가함에 따라 색상이 사라짐을 확인하였다.

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

경동맥에서 혈액유동의 수치해석 및 실험적 관찰 (Numerical Simulation and Experimental Observation of Blood Flows in the Carotid Artery)

  • 유상신;서상호;정태섭;조민태
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.41-44
    • /
    • 1995
  • A numerical technique is employed to simulate the flow patterns in the human carotid artery and a phantom of the carotid artery made of acrylic material is used to observe the flow phenomena in the carotid artery. For numerical analysis the idealized geometric shape of the carotid artery is constructed to portray the phantom. Steady momentum equation is solved by the finite element method and the numerical results are compared with the results of MRA and color Doppler images.

  • PDF

최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정 (Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor)

  • 임춘성;민경선
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로) (Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements))

  • 이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.117-124
    • /
    • 2014
  • 본 연구는 초음파 진단 장치에서 초음파 프로브 소자의 결함이 도플러 영상에 미치는 영향을 평가한 것이다. 초음파 프로브 소자결함의 여러 유형 중에서 동일한 방식으로 단선된 초음파 프로브 소자 수를 변화하면서, 도플러 모드 영상에 미치는 영향을 실험으로 살펴보았다. 실험 결과는 첫째, 소자 결함에 따른 도플러 속도는 도플러 소자군 부분에서 급격히 변화하고 있으며, 혈류 속도에는 크게 영향을 받지 않는 것으로 나타났다. 둘째, 도플러 소자군 주변에서 결함 있을 때 소자의 번호가 높은 쪽 소자의 결함에 의한 효과가 작은 것을 알 수 있었다. 셋째, 팬텀의 혈류 속도가 높을수록 도플러 속도 스펙트럼의 폭은 커지지만 크기는 감소하고 있다. 그리고 결함이 증가할수록 도플러 속도와 영상의 밝기의 분산이 더 커지는 것으로 나타났다. 이는 프로브 소자의 결함이 증가하면 전체적으로 시간 평균 도플러 속도 프로파일(TADVP)의 크기가 감소하며 고주파수 영역에서 더 빨리 떨어지는 것으로 알 수 있다.

좌심실 보조기를 이용한 3상형 박동류 모의 (Emulation of Tri-Phasic Pulsatile Flow Using LVAD)

  • 이동혁;김종효
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.313-320
    • /
    • 1998
  • 3상형 박동류는 인체 순환계 혈류의 일반적인 형태이다. 심혈관계의 여러 가지 상황을 모의하려면 이러한 3상형 박동류를 만들어 내는 것이 필수적이다. 본 연구에서는 3상형 박동류를 모의하기 위해서 전기유압식 좌심실보조기를 유리 팬텀과 고무 튜브와 같이 사용하였으며 혈류 모의 시스템의 제어변수를 선정하고 각 변수들의 변화에 대한 영향을 도플러 초음파를 이용하여 관찰하였다. 본 실험의 결과 협착 후위부 탄성과 지연시간이 3상형 혈류를 생성하는 중요한 요인이었다. 본 실험의 결과들은 다양한 혈류 운동을 모의할 수 있게 해 줌으로써 심혈관계의 여러현상을 설명하는 유용한 도구가 될 수 있을 것으로 기대된다.

  • PDF