• Title/Summary/Keyword: Doppler

Search Result 2,253, Processing Time 0.031 seconds

Classification of Doppler Audio Signals for Moving Target Using Hidden Markov Model in Pulse Doppler Radar (펄스 도플러 레이더에서 HMM을 이용한 이동표적의 도플러 오디오 신호 식별)

  • Sim, Jae-Hun;Lee, Jung-Ho;Bae, Keun-Sung
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • Classification of moving targets in Pulse Doppler Radar(PDR) for surveillance and reconnaissance purposes is generally carried out based on listening and training experience of Doppler audio signals by radar operator. In this paper, we proposed the automatic classification method to identify the class of moving target with Doppler audio signals using the Mel Frequency Cepstral Coefficients(MFCC) and the Hidden Markov Model(HMM) algorithm which are widely used in speech recognition and the classification performance was analyzed and verified by simulations.

A Study on Estimation of Doppler Frequency in a Current Velocity Measurement Radar (유속 측정 레이다에서의 도플러 주파수 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1551-1557
    • /
    • 2013
  • A current velocity measurement radar estimates Doppler frequencies to extract the corresponding surface velocity information. Therefore, it is required to maintain the high degree of reliability and accuracy of Doppler frequency estimates. However, Doppler spectra of water surface return echoes can have very widely varying shapes according to measurement environments and weather conditions. Therefore, serious problems may arise in maintaining the reliability and accuracy of conventional velocity estimating algorithm in a radar sensor. Therefore, in this paper, a newly suggested algorithm is proposed for improvement using estimation of peak Doppler frequencies. The proposed method shows that the more accurate velocity measurement can be possible comparing with the conventional one.

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

The Study of Aliasing and Incidence Angle Dependence of Doppler Image on Humeral Artery (상완동맥 Doppler 영상의 입사각 의존성과 Aliasing에 관한 연구)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.379-387
    • /
    • 2008
  • Among methods to eliminate aliasing effects, the method of increasing velocity scale gradually eliminated the phenomenon in which the direction of the blood flow appeared in reverse. It was done by increasing the velocity scale while maintaining other parameters in the same state. The method of setting the Doppler angle to $0^{\circ}$ did not show significant changes in the wave pattern of the spectrum according to the angle. In actual ultrasonography tests, more accurate tests are expected to be carried out by applying variations to the velocity scale under the considerations of speed, accuracy, and convenience of the examination. The results showed that blood flow velocity increases exponentially according to the Doppler Angle. When the angle goes over $70^{\circ}$, the velocity value increases to an unmeasurable state. This indicates that in blood flow velocity measurements, the blood flow velocity is very dependent on the Doppler Angle. It also shows that the error increases when the incidence angle to the direction of blood flow exceeds $60^{\circ}$, and when the angle exceeds $70^{\circ}$, the error becomes even greater. In addition, he experiment results showed that an angle below $60^{\circ}$ is appropriate and for blood flow velocity measurements in extremity vessels, the most appropriate Doppler Angle is from $45^{\circ}$ to $60^{\circ}$.

  • PDF

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

Determination of Flow Direction by Using an Acousto-Optic Effect (광음향 변조효과를 이용한 유체의 방향 결정)

  • 김규욱
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.34-36
    • /
    • 1990
  • The flow direction in a glass tube is measured by using a forward scatering dual beam laser Doppler velocimeter with an acousto-optic modulator. We can determine the flow direction by measuring the shifted Doppler frequency which is dependent on the order of modulation of the laser frequency shifting moves only the Doppler signal, enabling complete separation of the Pedestal and Doppler singal.

  • PDF

A Method for Noninvasive Diagnosis of Bone using Ultrasonic Doppler Method (초음파 Doppler법에 의한 생체 경조직의 비침투적인 진단을 위한 기초실험)

  • 박무훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.7
    • /
    • pp.3-11
    • /
    • 1998
  • 본 논문에서는 분포정수선로의 간단한 모델을 이용해서, 외부에서 진동을 가했을 때 에 뼈 표면에서 발생하는 굴곡파의 전파속도와 종파의 전파속도를 구할 수 있는 새로운 측 정원리를 제안했다. 이 측정원리를 이용해서, 봉(brass, polymethylmethacrylate)표면에 발생 하는 정재파에 대한 속도의 공간분포를 laser Doppler법으로 측정해서, 각각의 주파수에 대 한 전파속도를 구했다. 이 새로운 측정방법은 in vivo에서 초음파 Doppler법을 이용해서 뼈 의 이상(골다공증, osteoporosis)진단의 가능성을 제시했다.

  • PDF

Ranging Data Accuracy in K13 S-Band Antenna

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.464-466
    • /
    • 2004
  • Ranging and 2-way Doppler measurements are very essential source for orbit determination in LEOP (Launch and Early Operation). This paper shows ranging system features of 13M TT &C antenna and test results recently acquired with KOMPSAT-l. Ranging and 2-way Doppler measurements were compared with KOMPSAT-I GPS telemetry data. Through comparison, it was found that constant and accurate ranging measurements are available with 13M antenna system. Ranging and Doppler measurement function is expected to be used for KOMPSAT-1 and KOMPSAT-2.

  • PDF

${\mu}$-wave imging by range-doppler method using the Linear-FM singnal (Linear-FM을 사용한 Range-Doppler 방식의 마이크로웨이브 영상)

  • Shu, Kyoung-Whoan;Lee, Gyoung-Soo;Ra, Jung-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.26-29
    • /
    • 1987
  • This paper concerns methods for ${\mu}$-wave imaging. The image reconstruction of an object by range-doppler preceding using the X-Band Linear-FM signal is presented from tile simulated data. The high degree of range resolution is achived using large signal band width and cross-range resolution is obtained by doppler processing.

  • PDF

Development of Single Doppler Color Display Interpretation System (단일 도플러 영상 자료 분석 시스템 개발)

  • 엄원근;김동호;이충기;오미림;나종천
    • Korean Journal of Remote Sensing
    • /
    • v.10 no.1
    • /
    • pp.31-42
    • /
    • 1994
  • SDIAS (Single Doppler Image Analysis System), which can estimate the vertical wind profiles from single Doppler color displays, is developed here. Various single Doppler velocity signatures are simulated using horizontally uniform wind fields that vary with height. This system is very simple and efficient for interpreting the color displays. So, SDIAS can be used to get some useful informations on wind for understanding the present weather situation and forecast.