• 제목/요약/키워드: Door-opening

검색결과 202건 처리시간 0.023초

독서자원과 그 협력방안을 위한 시도적 연구-경상북도를 중심으로

  • 김남석
    • 한국도서관정보학회지
    • /
    • 제3권
    • /
    • pp.1-31
    • /
    • 1976
  • If Y'ational developments are depend on the dex-elopment of regional >ociety and de~.elopment of regional society are rely on intellcctual delrelopment of members of regional society, going abreas! oi economic capacity. Estnhlis!l:r,ent of libraries as a treasure-house of mental resources and its Jet-elopment are inevit-able and important. But in every respect :f modern libraries are not equipped with contemporary devclij;!~i:c:\ulcornert of society. One c~i the resolving problems, like this, opening the door of the liI~-,\ulcornerr:~fa-c ilities, as one object, which located in every regional areas, u.9ng the existing facilities, the width of the library services mus: I)c opened. I-' ;- I n,> study is aimed at like the following: 1. is analysizing the situation ~vhich the library facilities of one ti:u~:sa!~d five hundred and fifty nine located here and there ir, Ii.;~-ui:gij~opkr ovince in Korea and s i s t ~t.l lousand seven hundred aid tliirl:~ six village libraries, for connecting as a library networks. 2. Tl\ulcornerc ivhole libraries in Kyungbook province and dividing into four ::arts as a Daegu, Phohang, Ahndong and Kimchun area as a transportation area, school area and resources area which exhibiting the view-point of helping-net~vorksl ike the following,

  • PDF

간이용 엘리베이터 장치 개선에 관한 연구 (A Study on the Improvement of Easy Elevator Equipment)

  • 위성동;구활본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.82-88
    • /
    • 2001
  • Manufactured easy elevator can drives from the first floor to fifth floor as sequence control circuit in cause opening than existing equipment of experiment and practice, the structure of in the first implementation process are hand-worked control component with push-button, L/S and relay, it is structured a lamp to express that the door open and moving of cage by mechanical action of For/Rev motor-braker of which load. The second structure of implement process to control from the first floor to the fifth floor with the PLC elevator program can control by the sensor of hand-operated function of L/Sl~L/S5 in time that the S/Wl~S/W5 of PLC control panel operates to the For/Rev. The function of two kind process that an elevator is driven by PLC program and the sequence control relay circuit is a mechanical relay sequence control field and it is equipment apparatus of it to get appropriately the technology of For/Rev in that mechanical operating cause of a load using the PLC program. Also the wring circuit using a plug, dissembly. the circuit and the principle of component, and PLC program with the function test can be used the implementation field to the total technology theory about FA.

  • PDF

인버터를 이용한 냉동용 압축기의 용량 제어 (Control of Refrigerating Compressor Capacity Using Inverter)

  • 양현석;김환성;김정훈;김상봉;김종수
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

승강기 관리시스템 운영 시 안전요소에 관한 비교연구 (The Comparative Study on Safety Factors at Elevator Management System Operation)

  • 박주봉;신승중
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.159-162
    • /
    • 2014
  • 최근 추세를 중심으로 특허청 분석에 따르면 12~08년 최근 5년 사이 엘리베이터 안전관련 특허출원이 급증하는 것을 확인할 수 있었고, 이를 안전에 대한 관심이 높아지고 있는 것으로 예측했다. 이에 본 논문은 13~09년 사이 승강기 안전 관련 특허자료를 취합 및 분석 후 시대별로 공통적으로 중요시 되는 승강기 안전요인이 안전제어, 비상제동, 도어개폐장치라는 것을 확인하였다. 신뢰성 분석을 통해 승강기 안전에 있어서 가중치가 높은 항목을 이 세 가지로 정의하고, 특허가 많이 출원된 요인을 시대적 배경을 통해 알아보고, 5년간의 자료를 기반으로 승강기 안전에 대한 사고예방기술을 종합하여 키넥트 장착 스카다시스템 승강기를 향후 승강기 제작 방향으로 제시한다.

고층건물 피난계단에서의 연돌효과 저감방안 연구 (A Study on Reduction Method of Stack Effect at Stairwell of High-Rise Building)

  • 김정엽;신현준
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.14-20
    • /
    • 2011
  • 건축물이 고층화되면서 피난을 위한 주요 시설인 피난계단에서는 수직적 구조로 인해 연돌효과의 영향이 크게 발생하고 있다. 동절기에 연돌효과로 인한 계단실의 압력상승으로 피난문을 열고 대피하는데 어려움이 있고, 피난계단의 연기안전을 위한 급기가압 제연시스템의 운전성능에 교란이 발생되기 때문에 피난계단에서의 연돌효과를 저감시켜야 더욱 안전한 대피환경을 제공할 수 있다. 본 연구에서는 고층 건물에서의 현장실험을 통해 피난계단에서의 연돌효과를 저감시킬 수 있는 방안을 도출하였고, 네트워크 모델을 사용한 수치해석을 수행하여 정량적이고 상세한 설계방안을 제시하였다. 현장실험 결과 피난계단의 저층부에서 피난계단으로 공기가 급기되고 고층부에서 피난계단의 외부로 공기가 배기되도록 공기의 흐름을 생성시켜 준다면 고층 건물의 피난계단에서의 연돌효과가 저감될 것으로 예측된다.

서울메트로 접지설비 표준화 방안 연구 (A Study on the Unification of the Grounding System of SeoulMetro)

  • 김균식;박한용;백유호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구 (A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction)

  • 이정윤;김정훈;김응식;김홍
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.

아파트의 겨울철 실내온열환경 실태와 생활요인 분석 (Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter)

  • 최윤정;정연홍
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF

초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구 (Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings)

  • 임채현;김범규;박용환
    • 한국방재학회 논문집
    • /
    • 제9권3호
    • /
    • pp.89-94
    • /
    • 2009
  • 초고층 주상복합 건축물은 구조적으로 수직샤프트의 길이가 길고 24시간 냉난방이 이루어지는 용도적인 특성으로 혹서기 심야시간대에 실내외 온도차에 의한 연돌효과가 다른 건물보다 크게 발생한다. 또한, 하부 층에는 개구율이 높은 판매시설 및 지하주차장 등이 위치하고 있어 중성대가 상대적으로 낮게 형성되는 압력분포 특성을 가지고 있다. 이러한 압력분포는 화재위험도가 높은 하부 층에서 화재발생 시 중성대 이상층 전체가 연기확산의 위험에 노출되고 출입문 개방장애 등의 피난장애를 가져올 수 있음을 예측할 수 있다. 이에 본 연구에서는 초고층주상복합건축물에서의 수직 및 수평 압력분포를 정상조건 및 배연창개방조건에 따라 계단실, 부속실, 복도에서의 압력을 측정하고 압력분포특성을 분석하였다.

노인주택의 출입구 및 이동공간의 디자인 기준에 대한 비교 (A Comparative Study on Design Guidelines for Entrance, Corridor and Stairway of the Elderly Housing)

  • 이지숙
    • 한국주거학회논문집
    • /
    • 제18권5호
    • /
    • pp.45-52
    • /
    • 2007
  • The demographic profile of the households will shift towards the 'older elderly'. There are need upgrading existing housing and new housing in aspect of floor plan, accessories, facilities and so on. The government should prepare the policy and standards of housing design for the aged and disabled in order to improving the residents' housing conditions. The purpose of this study is to compare Korean to foreign guidelines related to residential design for the elderly and disabled and find out the characteristics of our standards. It was accomplished by literature research. The results were as follows. There is disagreements between domestic standards over the clear door opening, the clear hallways and handrails at entrance. And the foreign standards are based on their wheelchair size, ours are founded on it's size which specified only maximum overall dimensions. So ours are seem to be lack of accuracy. Our standard of stairs is in details in comparison with other space components. But ours don't go into details than foreign ones over length of hand-rails, riser etc. And for recommendations denoting minimum and maximum height of various component, it should be preceded the specific survey on limits of reaching ability for the elderly and disabled.