• Title/Summary/Keyword: Dominant frequency

Search Result 1,019, Processing Time 0.029 seconds

On the Vibration Characteristics and Determination of Site Constants for Surface Blasting (노천굴발파의 진동특성과 입지상수 결정에 관한 연구)

  • 양형식;주재성
    • Explosives and Blasting
    • /
    • v.8 no.4
    • /
    • pp.23-29
    • /
    • 1990
  • Some surface blasting vibration was measured to determine site constants and vibration frequency was analyzed. The results are summarized as follows; 1) Design method to predict particle velocities was introduced using the logarithmic normal distribution characteristics of peak particle velocities. 2) Scaled distance diagram to determine limiting charge was presented. 3) Line fitness between particle velocity and scaled distance didn't depend on dominant component of vibration. Prevail fitness was in the order of transverese, peak, vertical and radial component. 4) Dominant component of particle velocity didn't related to drilling direction. Frequency was lowered as distance enlarged. Duration time of vibration was shortened as charge decreased.

  • PDF

Experimental and Theoretical Study on Main Noise Sources and Its Radiations of Upwind Wind Turbines (상류형 풍력 터빈의 주요 소음원과 방사소음에 대한 실험적/이론적 고찰)

  • Lee, Gwang-Se;Cheong, Cheol-Ung;Shin, Su-Hyun;Jung, Sung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.72-73
    • /
    • 2010
  • In this paper, the main noise sources and its radiated noise levels of upwind horizontal-axis wind turbines are experimentally and theoretically investigated. Theoretical predictions for indentifying the dominant source locations are made by using the empirical noise prediction model of Brooks et al. (1989) for the airfoil self noise. Through the comparison of theoretical results with the experimental results, turbulence-boundary-layer-trailing-edge (TBL-TE) noise is revealed to be the dominant source over all frequency range and separation and stall (S-S) noise is possibly important in the relative lower frequency range compared with TBL-TE noise.

  • PDF

Arytenoidopexy with Bilateral Vocal Cord Excision (laryngofissure) for the Relief of Laryngeal Paralysis (후두마비 개에 대한 피열연골고정술)

  • 연성찬;남치주;권오경
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.185-194
    • /
    • 1997
  • This study was conducted to assess the application of spectrograms in the diagnosis of laryngeal paralysis and the arytenoidopexy with bilateral vocal cord excision (laryngofissure) for the relief of laryngeal paralysis. Laryngeal paralysis represented two types of stridor A and B (AN, PN). There were significant differences in Dominant Frequency ( DF, p<0.01), which were $3590{\pm} 209.81 Hz, 7445\{pm}418.54 Hz$, respectively. After arytenoidopexy with bilateral vocal cord excision (laryngofissure), $PaO_{2} levels (100.57{\pm}7.59 mmHg) were more increased than that (86.5 {\pm} 3.34 mmHg)$ of pre-operative dogs.

  • PDF

A Study on the Design of Integrated Speech Enhancement System for Hands-Free Mobile Radiotelephony in a Car

  • Park, Kyu-Sik;Oh, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.45-52
    • /
    • 1999
  • This paper presents the integrated speech enhancement system for hands-free mobile communication. The proposed integrated system incorporates both acoustic echo cancellation and engine noise reduction device to provide signal enhancement of desired speech signal from the echoed plus noisy environments. To implement the system, a delayless subband adaptive structure is used for acoustic echo cancellation operation. The NLMS based adaptive noise canceller then applied to the residual echo removed noisy signal to achieve the selective engine noise attenuation in dominant frequency component. Two sets of computer simulations are conducted to demonstrate the effectiveness of the system; one for the fixed acoustical environment condition, the other for the robustness of the system in which, more realistic situation, the acoustic transmission environment change. Simulation results confirm the system performance of 20-25dB ERLE in acoustic echo cancellation and 9-19 dB engine noise attenuation in dominant frequency component for both cases.

  • PDF

Guidelines of Designing LRB for a Seismically Excited Cable-Stayed Bridge (지진 하중을 받는 사장교를 위한 납고무 받침의 설계 기준 제안)

  • 이성진;박규식;김운학;이인원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.326-333
    • /
    • 2003
  • Most long-span bridges such as a cable-stayed bridges have a number of long-period modes due to the flexibility, thus the design concept extending the natural period of structures using base isolation system may be difficult to use directly to these structures. But, the effectiveness of LRB for cable-stayed bridges is indicated in several papers. In this study, the guidelines of designing LRB for a seismically excited cable-stayed bridge using benchmark cable-stayed bridge are presented. The design properties of LRB are chosen that the design index(DI) is minimized or little changed for variation of properties. And the seismic performance of designed LRB is also investigated. The consequences show that the perforamnce of designed LRB is better than that of simply designed LRB for several history earthquakes. Moreover, the design properties of LRB are researched to several diffrent dominant frequency of earthquake. The results present that the plastic and elastic stiffness of LRB are affected by the dominant frequency of earthquake.

  • PDF

Review on the reliability of low frequency responses of locally operating sensors (국내 지진센서의 저주파 응답의 신뢰성에 관한 고찰)

  • 박동희;연관희;장천중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.35-42
    • /
    • 2002
  • Frequency responses for most of the local seismic sensors in Korea have been roughly checked by mutual comparison of Fourier spectra of seismic records from accelerometer and seismometer, both of which are installed at the same location. Especially, because the frequency content of the seismic energy is usually above 1 Hz for local earthquakes, the reliability of low frequency response could have not been evaluated. Fortunately a recent large earthquake, Ms=7.2 on 02/06/29 containing dominant low frequency energy makes it possible to check the low frequency response of the seismic sensors, especially EpiSensor and JC-V100. Considering two types of sensor pairs, (STS-2 and EpiSensor, JC-V100 and EpiSensor), the low frequency response of EpiSensor is confirmed first by comparison with STS-2 which has proved low frequency response. Second, reliable low frequency limit of instrumentally corrected seismic data from JC-V100 data is estimated to be about 0.03 Hz by comparison with EpiSensor data.

  • PDF

Association between Minimal Change Esophagitis and Gastric Dysmotility: A Single-Center Electrogastrography and Endoscopy Study in Children

  • Lim, Kyung In;Shim, Sung Bo;Tchah, Hann;Ryoo, Eell
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2018
  • Purpose: Minimal change esophagitis (MCE) is a reflux disease without mucosal breaks, known to be partially associated with abnormal gastric motor function. Electrogastrography (EGG) is commonly applied to assess gastric motor function in a noninvasive fashion. We aimed to determine the relationship between MCE and gastric myoelectrical activity (GME) recorded on EGG in children. Methods: We retrospectively assessed the records of 157 children without underlying disease who underwent both EGG and upper gastrointestinal endoscopy at Gachon University Gil Medical Center between January 2010 and June 2015. The children were stratified according to the appearance of the esophagus (normal vs. MCE). Between-group differences in EGG parameters and their correlation with each MCE finding were statistically analyzed. Results: Only the power ratio, one of the EGG parameters analyzed, differed significantly between the two groups (MCE, $1.68{\pm}3.37$ vs. normal, $0.76{\pm}1.06$; p<0.05), whereas the other parameters, such as dominant frequency, dominant power, and the ratio of abnormal rhythm, showed no differences. Among children with MCE, significant correlations were noted between erythema and power ratio (p<0.05), friability and postprandial dominant frequency (p<0.05), and edema and/or accentuation of mucosal folds and pre-prandial frequency (p<0.05). Helicobacter pylori infection correlated with postprandial arrhythmia (MCE, $33.59{\pm}15.52$ vs. normal, $28.10{\pm}17.23$; p<0.05). EGG parameters did not differ between children with normal esophagus and those with biopsy-proven chronic esophagitis. Conclusion: In children with MCE, gastric dysmotility may affect the development of MCE, manifesting as EGG abnormalities. H. pylori infection may also affect GME. However, larger prospective investigations are needed to confirm these findings.

Acoustic Emission of Heat Treated Compacted Graphite Iron under 873~1173 K (873~1173 K에서 열처리된 강화흑연강(Compacted Graphite Iron, CGI)의 음향방출 특성)

  • Nam, Ki-Woo;Ahn, Byung-Kun;Lee, Soo-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.415-421
    • /
    • 2013
  • CGI is gaining popularity in applications that require either greater strength, or lower weight than cast iron. Recently, compacted graphite iron has been used for diesel engine blocks, turbo housings and exhaust manifolds. This paper were assessed acoustic emission characteristics according to the mechanical properties change of degraded CGI340 during 1-24 hours at 873~1173 K. In results of pencil lead fracture test, the dominant frequency and the velocity of base metal were 97 kHz and 5490 m/sec, respectively. The base metal in a tensile test was obtained relatively high dominant frequency. However, the heat treated materials, the longer the heat treatment time, the higher the heat treatment temperature, were obtained in the area of lower frequencies. This phenomenon appears by long-term use.

Development of Electrogastrography System (위전도 계측시스템의 개발)

  • Han, W.T.;Kim, I.Y.;Kim, W.K.;Park, K.W.;Kim, Hui-Chan;Son, J.I.;Rhee, P.L.;Rhee, J.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.403-406
    • /
    • 1997
  • Electrogastrogaphy(EGG) is the technique by which gastric myoelectrical activity is recorded noninvasively, from electrodes on the abdominal skin. Despite many attempts made over the decades, the clinical application of the EGG signal has not improved to the identification of waveform characteristics using comparison of EGG signal to be detected other EGG system. Cutaneous measurements of EGG are yet to be standardized in methods of detection and analysis. This may be responsible in part for some of the variability in the results. Thus, we develope EGG system composed of amplifiers, analysis methods, patient database or standardization. we introduce configurations of EGG system and their functions. Several important EGG parameters are introduced, including the dominant frequency and power of the EGG, the relative, period EGG-dominant frequency and power, the instability coefficient of EGG-dominant frequency and power, standard deviation, the percentage of running spectrum activity of gastric slow waves.

  • PDF

An Adaptive Tuned Heave Plate (ATHP) for suppressing heave motion of floating platforms

  • Ruisheng Ma;Kaiming Bi;Haoran Zuo
    • Smart Structures and Systems
    • /
    • v.31 no.3
    • /
    • pp.283-299
    • /
    • 2023
  • Structural stability of floating platforms has long since been a crucial issue in the field of marine engineering. Excessive motions would not only deteriorate the operating conditions but also seriously impact the safety, service life, and production efficiency. In recent decades, several control devices have been proposed to reduce unwanted motions, and an attractive one is the tuned heave plate (THP). However, the THP system may reduce or even lose its effectiveness when it is mistuned due to the shift of dominant wave frequency. In the present study, a novel adaptive tuned heave plate (ATHP) is proposed based on inerter by adjusting its inertance, which allows to overcome the limitation of the conventional THP and realize adaptations to the dominant wave frequencies in real time. Specifically, the analytical model of a representative semisubmersible platform (SSP) equipped with an ATHP is created, and the equations of motion are formulated accordingly. Two optimization strategies (i.e., J1 and J2 optimizations) are developed to determine the optimum design parameters of ATHP. The control effectiveness of the optimized ATHP is then examined in the frequency domain by comparing to those without control and controlled by the conventional THP. Moreover, parametric analyses are systematically performed to evaluate the influences of the pre-specified frequency ratio, damping ratio, heave plate sizes, peak periods and wave heights on the performance of ATHP. Furthermore, a Simulink model is also developed to examine the control performance of ATHP in the time domain. It is demonstrated that the proposed ATHP could adaptively adjust the optimum inertance-to-mass ratio by tracking the dominant wave frequencies in real time, and the proposed system shows better control performance than the conventional THP.