• 제목/요약/키워드: Dominant frequency

검색결과 1,019건 처리시간 0.026초

노천굴발파의 진동특성과 입지상수 결정에 관한 연구 (On the Vibration Characteristics and Determination of Site Constants for Surface Blasting)

  • 양형식;주재성
    • 화약ㆍ발파
    • /
    • 제8권4호
    • /
    • pp.23-29
    • /
    • 1990
  • Some surface blasting vibration was measured to determine site constants and vibration frequency was analyzed. The results are summarized as follows; 1) Design method to predict particle velocities was introduced using the logarithmic normal distribution characteristics of peak particle velocities. 2) Scaled distance diagram to determine limiting charge was presented. 3) Line fitness between particle velocity and scaled distance didn't depend on dominant component of vibration. Prevail fitness was in the order of transverese, peak, vertical and radial component. 4) Dominant component of particle velocity didn't related to drilling direction. Frequency was lowered as distance enlarged. Duration time of vibration was shortened as charge decreased.

  • PDF

상류형 풍력 터빈의 주요 소음원과 방사소음에 대한 실험적/이론적 고찰 (Experimental and Theoretical Study on Main Noise Sources and Its Radiations of Upwind Wind Turbines)

  • 이광세;정철웅;신수현;정성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.72-73
    • /
    • 2010
  • In this paper, the main noise sources and its radiated noise levels of upwind horizontal-axis wind turbines are experimentally and theoretically investigated. Theoretical predictions for indentifying the dominant source locations are made by using the empirical noise prediction model of Brooks et al. (1989) for the airfoil self noise. Through the comparison of theoretical results with the experimental results, turbulence-boundary-layer-trailing-edge (TBL-TE) noise is revealed to be the dominant source over all frequency range and separation and stall (S-S) noise is possibly important in the relative lower frequency range compared with TBL-TE noise.

  • PDF

후두마비 개에 대한 피열연골고정술 (Arytenoidopexy with Bilateral Vocal Cord Excision (laryngofissure) for the Relief of Laryngeal Paralysis)

  • 연성찬;남치주;권오경
    • 한국임상수의학회지
    • /
    • 제14권2호
    • /
    • pp.185-194
    • /
    • 1997
  • This study was conducted to assess the application of spectrograms in the diagnosis of laryngeal paralysis and the arytenoidopexy with bilateral vocal cord excision (laryngofissure) for the relief of laryngeal paralysis. Laryngeal paralysis represented two types of stridor A and B (AN, PN). There were significant differences in Dominant Frequency ( DF, p<0.01), which were $3590{\pm} 209.81 Hz, 7445\{pm}418.54 Hz$, respectively. After arytenoidopexy with bilateral vocal cord excision (laryngofissure), $PaO_{2} levels (100.57{\pm}7.59 mmHg) were more increased than that (86.5 {\pm} 3.34 mmHg)$ of pre-operative dogs.

  • PDF

A Study on the Design of Integrated Speech Enhancement System for Hands-Free Mobile Radiotelephony in a Car

  • Park, Kyu-Sik;Oh, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권2E호
    • /
    • pp.45-52
    • /
    • 1999
  • This paper presents the integrated speech enhancement system for hands-free mobile communication. The proposed integrated system incorporates both acoustic echo cancellation and engine noise reduction device to provide signal enhancement of desired speech signal from the echoed plus noisy environments. To implement the system, a delayless subband adaptive structure is used for acoustic echo cancellation operation. The NLMS based adaptive noise canceller then applied to the residual echo removed noisy signal to achieve the selective engine noise attenuation in dominant frequency component. Two sets of computer simulations are conducted to demonstrate the effectiveness of the system; one for the fixed acoustical environment condition, the other for the robustness of the system in which, more realistic situation, the acoustic transmission environment change. Simulation results confirm the system performance of 20-25dB ERLE in acoustic echo cancellation and 9-19 dB engine noise attenuation in dominant frequency component for both cases.

  • PDF

지진 하중을 받는 사장교를 위한 납고무 받침의 설계 기준 제안 (Guidelines of Designing LRB for a Seismically Excited Cable-Stayed Bridge)

  • 이성진;박규식;김운학;이인원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.326-333
    • /
    • 2003
  • Most long-span bridges such as a cable-stayed bridges have a number of long-period modes due to the flexibility, thus the design concept extending the natural period of structures using base isolation system may be difficult to use directly to these structures. But, the effectiveness of LRB for cable-stayed bridges is indicated in several papers. In this study, the guidelines of designing LRB for a seismically excited cable-stayed bridge using benchmark cable-stayed bridge are presented. The design properties of LRB are chosen that the design index(DI) is minimized or little changed for variation of properties. And the seismic performance of designed LRB is also investigated. The consequences show that the perforamnce of designed LRB is better than that of simply designed LRB for several history earthquakes. Moreover, the design properties of LRB are researched to several diffrent dominant frequency of earthquake. The results present that the plastic and elastic stiffness of LRB are affected by the dominant frequency of earthquake.

  • PDF

국내 지진센서의 저주파 응답의 신뢰성에 관한 고찰 (Review on the reliability of low frequency responses of locally operating sensors)

  • 박동희;연관희;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.35-42
    • /
    • 2002
  • Frequency responses for most of the local seismic sensors in Korea have been roughly checked by mutual comparison of Fourier spectra of seismic records from accelerometer and seismometer, both of which are installed at the same location. Especially, because the frequency content of the seismic energy is usually above 1 Hz for local earthquakes, the reliability of low frequency response could have not been evaluated. Fortunately a recent large earthquake, Ms=7.2 on 02/06/29 containing dominant low frequency energy makes it possible to check the low frequency response of the seismic sensors, especially EpiSensor and JC-V100. Considering two types of sensor pairs, (STS-2 and EpiSensor, JC-V100 and EpiSensor), the low frequency response of EpiSensor is confirmed first by comparison with STS-2 which has proved low frequency response. Second, reliable low frequency limit of instrumentally corrected seismic data from JC-V100 data is estimated to be about 0.03 Hz by comparison with EpiSensor data.

  • PDF

Association between Minimal Change Esophagitis and Gastric Dysmotility: A Single-Center Electrogastrography and Endoscopy Study in Children

  • Lim, Kyung In;Shim, Sung Bo;Tchah, Hann;Ryoo, Eell
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제21권1호
    • /
    • pp.20-27
    • /
    • 2018
  • Purpose: Minimal change esophagitis (MCE) is a reflux disease without mucosal breaks, known to be partially associated with abnormal gastric motor function. Electrogastrography (EGG) is commonly applied to assess gastric motor function in a noninvasive fashion. We aimed to determine the relationship between MCE and gastric myoelectrical activity (GME) recorded on EGG in children. Methods: We retrospectively assessed the records of 157 children without underlying disease who underwent both EGG and upper gastrointestinal endoscopy at Gachon University Gil Medical Center between January 2010 and June 2015. The children were stratified according to the appearance of the esophagus (normal vs. MCE). Between-group differences in EGG parameters and their correlation with each MCE finding were statistically analyzed. Results: Only the power ratio, one of the EGG parameters analyzed, differed significantly between the two groups (MCE, $1.68{\pm}3.37$ vs. normal, $0.76{\pm}1.06$; p<0.05), whereas the other parameters, such as dominant frequency, dominant power, and the ratio of abnormal rhythm, showed no differences. Among children with MCE, significant correlations were noted between erythema and power ratio (p<0.05), friability and postprandial dominant frequency (p<0.05), and edema and/or accentuation of mucosal folds and pre-prandial frequency (p<0.05). Helicobacter pylori infection correlated with postprandial arrhythmia (MCE, $33.59{\pm}15.52$ vs. normal, $28.10{\pm}17.23$; p<0.05). EGG parameters did not differ between children with normal esophagus and those with biopsy-proven chronic esophagitis. Conclusion: In children with MCE, gastric dysmotility may affect the development of MCE, manifesting as EGG abnormalities. H. pylori infection may also affect GME. However, larger prospective investigations are needed to confirm these findings.

873~1173 K에서 열처리된 강화흑연강(Compacted Graphite Iron, CGI)의 음향방출 특성 (Acoustic Emission of Heat Treated Compacted Graphite Iron under 873~1173 K)

  • 남기우;안병건;이수철
    • 비파괴검사학회지
    • /
    • 제33권5호
    • /
    • pp.415-421
    • /
    • 2013
  • CGI는 주철보다 큰 강도 또는 작은 무게가 요구되는 응용에서 인기를 얻고 있다. 최근, 강화흑연강은 디젤 엔진 블록, 터보 하우징 및 배기 매니폴드에 사용된다. 이 논문은 873~1173 K에서 1~24 시간 동안 열화된 CGI340의 기계적 성질의 변화에 따른 음향방출 특성을 평가하였다. 연필심 파괴시험 결과에서, 탁월주파수 및 모재의 속도는 각각 97 kHz와 5,490 m/s이었다. 인장시험에서 모재는 상대적으로 높은 탁월주파수를 얻었다. 그러나 열처리된 재료, 열처리 시간이 길고, 열처리 온도가 높을수록, 낮은 주파수의 영역에서 얻어졌다. 이러한 현상은 장기간의 사용에 의해 나타난다.

위전도 계측시스템의 개발 (Development of Electrogastrography System)

  • 한완택;김인영;김원기;박기원;김희찬;손정일;이풍렬;이종철
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.403-406
    • /
    • 1997
  • Electrogastrogaphy(EGG) is the technique by which gastric myoelectrical activity is recorded noninvasively, from electrodes on the abdominal skin. Despite many attempts made over the decades, the clinical application of the EGG signal has not improved to the identification of waveform characteristics using comparison of EGG signal to be detected other EGG system. Cutaneous measurements of EGG are yet to be standardized in methods of detection and analysis. This may be responsible in part for some of the variability in the results. Thus, we develope EGG system composed of amplifiers, analysis methods, patient database or standardization. we introduce configurations of EGG system and their functions. Several important EGG parameters are introduced, including the dominant frequency and power of the EGG, the relative, period EGG-dominant frequency and power, the instability coefficient of EGG-dominant frequency and power, standard deviation, the percentage of running spectrum activity of gastric slow waves.

  • PDF

An Adaptive Tuned Heave Plate (ATHP) for suppressing heave motion of floating platforms

  • Ruisheng Ma;Kaiming Bi;Haoran Zuo
    • Smart Structures and Systems
    • /
    • 제31권3호
    • /
    • pp.283-299
    • /
    • 2023
  • Structural stability of floating platforms has long since been a crucial issue in the field of marine engineering. Excessive motions would not only deteriorate the operating conditions but also seriously impact the safety, service life, and production efficiency. In recent decades, several control devices have been proposed to reduce unwanted motions, and an attractive one is the tuned heave plate (THP). However, the THP system may reduce or even lose its effectiveness when it is mistuned due to the shift of dominant wave frequency. In the present study, a novel adaptive tuned heave plate (ATHP) is proposed based on inerter by adjusting its inertance, which allows to overcome the limitation of the conventional THP and realize adaptations to the dominant wave frequencies in real time. Specifically, the analytical model of a representative semisubmersible platform (SSP) equipped with an ATHP is created, and the equations of motion are formulated accordingly. Two optimization strategies (i.e., J1 and J2 optimizations) are developed to determine the optimum design parameters of ATHP. The control effectiveness of the optimized ATHP is then examined in the frequency domain by comparing to those without control and controlled by the conventional THP. Moreover, parametric analyses are systematically performed to evaluate the influences of the pre-specified frequency ratio, damping ratio, heave plate sizes, peak periods and wave heights on the performance of ATHP. Furthermore, a Simulink model is also developed to examine the control performance of ATHP in the time domain. It is demonstrated that the proposed ATHP could adaptively adjust the optimum inertance-to-mass ratio by tracking the dominant wave frequencies in real time, and the proposed system shows better control performance than the conventional THP.