• 제목/요약/키워드: District heating

검색결과 437건 처리시간 0.026초

유한요소 시뮬레이션을 통한 지역난방열배관 특성 평가 및 강화이형관의 제안 (Design Validation and Improvement of District Heating Pipe Using FE Simulation)

  • 김주용;김호범;고현일;안영모;조종두
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.337-345
    • /
    • 2009
  • This paper investigates the reliability of district heating pipes at thermo-elastic fatigue loading. District heating pipes, subjected to $120^{\circ}C$ and $16kg_f/cm^2$ due to water distributing service through inside the pipes, should endure long term cyclic thermal-mechanical loadings. The heating pipes are the co-centric tubes of steel pipe, poly urethane(PUR) insulator, and high density poly ethylene(HDPE) case. On installation, foam pad is externally wrapped for accommodating stress reduction near the bend sections of pipes. However, there have been frequent reports on the failures of bend sections in the middle of long term service. This study scrutinizes the observed failures near the bend sections through applying the finite element methods. Specially in this study, heating pipes are studied on the influence of foam padding on failures and proposed new designs for reinforced bend without foam pad.

지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션 (Measurement and Simulation of Heating Energy for Apartments with District Heating)

  • 이은주;이두영;홍희기;김영균
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

지역난방 공동주택의 단지별 난방사용량 분석 연구 (Heating Energy Consumption Analysis of the Apartment Applied District Heating System)

  • 박선효;이현정;권경우;이병석;김양섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.293-298
    • /
    • 2012
  • The purpose of this study is performance validation of district heating apartments about heating energy consumption and analysis of energy consumption by unit characteristics. The heating energy consumption of the existing apartments was analyzed and the analyzed results will be used for energy saving technology development and policy making. The heating energy consumption data about total 78 apartment complexes, 56,910 units in Gangnam-Gu, Seoul, Korea were investigated from October, 2010 to April 2011. The analysis results are as follows; The mean heating energy consumption is 98[kWh/m2]. The energy consumption of Apgujung-Dong, Daechi-Dong is higher than that of mean valuse. The energy consumption deviation by deterioration, unit area, core type and regional group is very high. Specially, building deterioration casts a long shadow.

  • PDF

개별난방과 지역난방방식의 에너지절감 및 환경개선효과 분석 (Assessment for the effect of heating systems on the energy consumption and environment)

  • 임용훈;김혁주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.466-473
    • /
    • 2007
  • The comparison for the performance of heating systems, district heating and separate heating and power, is carried out in terms of energy consumption and environment on the basis of real operating data. The efficiency of boiler and the heat loss within the housing are assumed with reasonable manner due to the lack of reliable data regarding those quantities. The assessment for the established criteria of previous studies is performed and the new criteria for the analysis is proposed. It is shown that the district heating system is superior to the separate heating and power system from the point of view of reduction of energy use and environment improvement. The sensitivity study for those quantities with uncertainty such as the boiler efficiency and heat loss within the housing is carried out also and the reasons for the analysis results are discussed in detail.

  • PDF

배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석 (Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation)

  • 임신영;이종준;전영신;김형택
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

소규모 지역냉난방 시스템 최적설계 시뮬레이션 (The Simulation Approach for the Optimal Design of Small Scale District Heating and Cooling System)

  • 임용훈;박화춘;조수;장철용;정모
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.147-154
    • /
    • 2008
  • A simulation program is developed for the optimal design of small scale district heating and cooling system. Main features for the simulation program are the reliability and the easiness for the optimal design of the DHC(District Heating and Cooling) systems. In order for implementing those features, the operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types, of which the corresponding district consist, such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features and the overall procedure of the simulation are described in brief in this paper. The results of the simulation for several test cases will be presented in subsequent study.

  • PDF

지역난방 공동주택의 건축물 에너지절약 설계기준 강화에 따른 난방에너지 사용량 분석 (Analysis of Heating Energy Consumption of District Heated Apartment with respect to Reinforcement of Building Energy-saving Design Criteria)

  • 이성우;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.16-22
    • /
    • 2011
  • Since 1970s, energy-saving design criteria of buildings has been improved through numerous revisions. The purpose of this research is to show how energy saving design criteria affects heating energy consumption of apartments using district heating. Heating energy consumption has been measured in 4 apartments located in Gyeonggi province, Korea from Nov. 1,2007 through Oct. 31, 2008. Collected data was regressed to linear correlations. Heating energy consumptions were calculated for past, present and future energy-saving design criteria, which are outdoor temperature, ventilation and insulation. The results show that present design criteria has reduced heating energy consumption by 15%, and the future criteria will reduce the energy consumption by 42% compared to the criteria before 2001.

난방방식별 에너지사용 특성 실증 분석 I: 실증 시스템 구축 (Experimental Investigation for the Characteristics of Energy-Usage of Heating Systems in Apartment Complex Part I: Experiment System Implementation)

  • 임용훈;최규성;김혁주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2007
  • The experimental implementation for different heating systems, district heating and separate heating and power, is discussed in the analysis of the characteristics of energy-usage in apartment complex. Total 20 families are chosen for the experiment, 10 for the district heating and the others for separate heating and power. Among the 10 families, the operating temperature was forced to be controled within certain range of temperatures for 5 ones, and it was left as usual for the other ones. The configuration and general features of each facilities and data acquisition systems are mentioned in brief and the technical specifications for it are also described. The analysis for the experiment results of this investigation is going to be carried out and published in a subsequent paper.

  • PDF

지역난방용 중온수 열원 유기랭킨사이클 성능 특성 (Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source)

  • 박우진;유호선
    • 플랜트 저널
    • /
    • 제12권1호
    • /
    • pp.29-36
    • /
    • 2016
  • 최근 늘어가는 에너지 수요를 화석연료에만 의존 할 수 없게 되면서 대체 에너지의 중요성이 대두되고 있으며, 이러한 상황에서 유기랭킨 사이클(Organic Rankine Cycle, 이하 ORC)등 산업체 폐열, 태양열, 지열, 해수 온도차 등의 저등급 에너지를 효과적으로 활용하기 위한 많은 연구가 진행되고 있다. 본 연구에서는 지역난방 축열시 회수수를 혼합하지 않고 ORC를 이용하여 하부사이클을 구성하여 성능해석 상용프로그램으로 작동유체 및 운전특성을 예측하였다. 지역난방수 운전조건인 열원 온도 $120^{\circ}C$, 열원 유량 $163m^3/h$(회수수 유량을 고려한 값)로 하고 이 온도에 적합한 다수의 작동유체를 선정하여 성능해석을 수행하였으며, 최고의 성능이 나타난 R245fa의 경우 269.2kW출력과 6.37%효율을 얻을 수 있었다. 또한 ORC 시스템의 응축기 압력변화에 따라 지역난방 회수수 온도가 $57.3{\sim}85^{\circ}C$범위에 형성됨으로서 보일러 입구온도상승에 따른 연료 절감 효과가 예상되었다.

  • PDF

지역난방수 공급관 에어벤트 부식 파손 분석 (Corrosion Failure Analysis of Air Vents Installed at Heat Transport Pipe in District Heating System)

  • 이형준;채호병;조정민;김우철;정준철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.189-195
    • /
    • 2020
  • Two air vents situated on a heat transport pipe in district heating system were exposed to the same environment for 10 years. However, one air vent was more corroded than the other. It also had a hole on the top of the front-end pipe. Comparative analysis was performed for these air vents to identify the cause of corrosion and establish countermeasures. Through experimental observation of the damaged part and analyses of powders sampled from air vents, it was found that corrosion was initiated at the top of the front-end pipe. It then spread to the bottom. Energy dispersive X-ray spectroscopy results showed that potassium and chlorine were measured from the corroded product in the damaged air vent derived from rainwater and insulation, respectively. The temperature of the damaged air vent was maintained at 75 ~ 120 ℃ by heating water. Rainwater-soaked insulation around the front-end pipe had been hydrolyzed. Therefore, the damaged air vent was exposed to an environment in which corrosion under insulation could be facilitated. In addition, ion chromatography and inductively coupled plasma measurements indicated that the matrix of the damaged front-end pipe contained a higher manganese content which might have promoted corrosion under insulation.