Abstract
Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.
Keywords
Ondol; Heating; District heating system; Outdoor reset control; Flow control;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Hong, H. K. and Kim, S. W., 2010, Method and analysis of dynamic simulation for Ondol heating, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 6, pp. 375-382.   과학기술학회마을
2 Kim, S. K., Hong, H. K., Kim, S. W., and Kim, J. T., 2010, Method and analysis of a dynamic simulation of Ondol heating, Indoor and Built Environment, Vol. 20, No. 1, pp. 112-119.
3 Hong, H. K. and Kim, S. W., 2010, Adjustment of valve opening in Ondol hot water distributor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 6, pp. 460-467.   과학기술학회마을
4 Won, D. H. and Kim, H. G., 2008, The economics value of residential heating systems in house price, Korean Energy Economic Review, Vol. 7, No. 2, pp. 75-101.
5 Kim, J. W., Ryu, J. S., Cho, S. H., and Lee, Y. S., 2011, An experimental study on application of outdoor reset control for apartment house by district heating system, Proceedings of the SAREK 2010 Summer Conference, pp. 221-226.
6 Hong, S. K., Kim, J. W., Lyu, S. B., and Cho, S. H., 2011, An experimental study of predictive optimal control for apartment house, Proceedings of the SAREK 2011 Summer Conference, pp. 1343-1348.
7 Park, Y. W., Yoo, H. S., and Hong, H. K., 2005, Analysis of heating energy in a Korean-style apartment building 3 : The effect of room condition settings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 8, pp. 722-728.   과학기술학회마을
8 Jang, H. J., 2009, Study on the optimum air change rate in residences, Korean Journal of the KARSE, Vol. 26, No. 2, pp. 73-76.
9 Lee, B. J., Chung, D. Y. and Hong, H. K., 2004, Analysis of heating energy in a Korean-style apartment building 2 : the difference according to heating type, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 16, No. 5, pp. 459-466.   과학기술학회마을
10 Jin, H. G., Yoo, M. H., Jeong, C. H., Yeo, M. S., and Kim, K. W., 2013, Analysis of water supply characteristics of the heating system in an apartment house complex using district heating source, Journal of Architectural Institute of Korea, Vol. 29, No. 4, pp. 267-274.