• 제목/요약/키워드: Distribution pipe

검색결과 620건 처리시간 0.028초

진동세관형 히트파이프를 이용한 태양열 집열기 개발에 관한 기초연구(I);작동유체의 내부 충진율과 경사각도의 영향 (Study on development of Solar Collector using Oscillating Capillary Tube Heat Pipe)

  • 김태훈;김종수;하수정;임용빈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1394-1399
    • /
    • 2004
  • Recently solar energy is representative in the technology development and spread of alternative energy. Specially in condition of solar collectors, they have had very various shape. This paper reports experimental study about the application of Oscillating Capillary Tube Heat Pipe to flat-plate solar collector. In conclusion, overall temperature distribution of OCHP was investigated by charging ratio and inclination angle. Respective charging ratio is 15%, 20%, 40% and respective inclination angle is horizontal, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, perpendicular. As a result of experiment, charging ratio 20% heat pipe has shown the most uniform temperature distribution and also performance of heat transfer has been the best.

  • PDF

동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향 (Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion)

  • 조관형;김선일;우달식
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

순수물질 냉매에 대한 증발엔탈피의 새로운 상관식 (A new correlation of the enthalpy of vaporization for pure refrigerants)

  • 박경근
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.449-455
    • /
    • 1998
  • A header' is the device that makes uniform flow distribution in all branches from header of heat exchangers, pipe burner or chemical equipments. In this study, experimental tests have been performed in order to investigate the flow distribution characteristics in a straight header and tapered header which have 6 and 11 glass pipe branches. The experimental equipment consists of a water circulation system where the fluid velocity in each glass pipe is measured by Ar-ion LDV system. From the experiments and the theoretical equation, it could be recommended that tapered header should be determined so that its internal velocities inside the header become uniform according to taper of the header and number of attached branches for uniform flow distribution in energy systems.

  • PDF

공동주택 바닥용 시멘트 모르타르의 복합강화법 변화에 따른 열전도 특성 (Properties of Thermal Conductivity of Cement Mortar for Apartment Housing Floor Using Combined Strengthening Method)

  • 윤길봉;전충근;정성철;윤기원;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.243-248
    • /
    • 2001
  • The objective of this study is to investigate the thermal conductivity of cement mortar for apartment housing floor using expansive admixture, copper fiber, cower lathe, hollowed aluminum plate. According to test results, temperature at point (a) located above heating pipe does not show significant variation with age, and temperature at (b), which is located at the finishing surface above heating pipe, and temperature at (c), which is located at center surface between heating pipe has remarkable change. Temperature distribution sat (b) are in order for, structure containing copper fiber>plain structure>structure containing hollowed aluminum plate>structure containing expansive admixture. Temperature distribution, shows high tendency in order for, structure containing copper fiber>structure containing copper lathe>structure containing hollowed aluminum plate>plain structure>structure containing expansive admixture. (a) estimation of temperature distribution is determined with the variation of temperature between (b) point and (c) point during 60 minutes heating.

  • PDF

확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가 (Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function)

  • 최정훈;구재민;석창성;송원근
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.707-712
    • /
    • 2008
  • The fatigue characteristics of a material or a structure are generally derived from fatigue tests of standard specimens. However, test results of standard specimens are different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristics of a real waterwork pipe. Also, to evaluate fatigue characteristic based on life distribution, the statistical fatigue characteristics were analyzed by the normal distribution and related data of P-S-N curve.

요인실험계획을 이용한 수도관 생물막 형성 영향 인자의 효과 분석 (Analysis of Effects of Factors Influencing Biofilm Formation in Drinking Water Distribution Pipe Using Factorial Experimental Design)

  • 박세근;최성찬;김영관
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.181-192
    • /
    • 2005
  • This study evaluated the effect of factors influencing the initial biofilm formation in drinking water distribution pipe by running experiments using a $2^{4-1}$ fractional factorial experimental design with a replicate. Important variables used for assessing biofilm formation included BDOC(biodegradable dissolved organic carbon), viable heterotrophic bacteria present in drinking water, water temperature, and shear stress at two levels each. Based on the statistical analysis of biofilm levels measured as attached HPC(heterotrophic plate count) and community-level assay, the main factors that have significant effects on biofilm formation were found to be viable heterotrophic bacteria and BDOC. Water temperature only exhibited significant effect on the levels of attached HPC, while shear stress was not a significant factor under given conditions. Moreover, the statistical analysis revealed that interactions between the important variables were not statistically significant at a 0.05 significance level.

밀폐형 함침법을 이용한 CFRP 사각 파이프 인발성형에서 인발장치 및 경화금형에 관한 연구 (A study on the drawing device and curing mold in CFRP rectangular pipe pultrusion process using a closed impregnation method)

  • 강병수;유형민
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.60-65
    • /
    • 2022
  • In the pultrusion process for the CFRP (Carbon fiber reinforced plastic) rectangular pipe, the drawing device is eseential which can continuously produces products and draws the carbon fiber tow. In addition, since the degree of cure changes depending on the temperature and the temperature ditribution of the curing mold changes depending on the pultrusion speed, the temperature distribution of the curing mold under certain conditions must be studied before processing. In this study, in the pultrusion process using a closed impregnation method, which has several advantages compared to the general pultrusion process using a open bath impregnation method, the drawing force required to pull the carbon fiber tows and the temperature distribution of the curing mold was analyzed to design the drawing device and the curing mold efficiently.

성토하에 매설된 강성관의 접촉응륜력 (Contact Pressure around the Buried Rigid pipe under Embankment)

  • 안중선;강병희
    • 한국지반공학회지:지반
    • /
    • 제1권2호
    • /
    • pp.7-16
    • /
    • 1985
  • 성토 하에 매설된 강성관에 있어서 관의 두께, 매설상태, 성토높이, 성토흙의 탄성계수, 트렌치의 폭 및 깊이 등이 매설관에 작용하는 응력에 미치는 영향에 대해서 유한요소법의 선형해석을 이용하여 검토하였다. 관 주위의 수직접촉헌력의 분포와 수직하중을 선형중도귀식으로 나타내었으며, Marston-Spangler 이론에 의해서 구한 수직하중은 유한요소해석에 의한 값보다 일반적으로 크다. 그리고 Marston Spangler이론에서 이용되는 침하비는 항상 일정하지 않고 위에서 언급한 여러가지 요인의 유기에 따라서 달라진다는 사실을 알았다.

  • PDF

유수대류계수에 관한 실험적 연구 (Experimental Study on Coefficient of Flow Convection)

  • 정상은;오태근;양주경;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2000
  • Pipe cooling method is widely used for reduction of hydration heat and control of cracking in mass concrete structures. However, in order to effectively apply pipe cooling systems to concrete structure, the coefficient of flow convection relating the thermal transfer between inner stream of pipe and concrete must be estimated. In this study, a device measuring the coefficient of flow convection is developed. Since a variation of thermal distribution caused by pipe cooling has a direct effect in internal forced flows, the developed testing device is based on the internal forced flow concept. Influencing factors on the coefficient of flow convection are mainly flow velocity, pipe diameter and thickness, and pipe material. finally a prediction model of the coefficient of flow convection is proposed using experimental results from the developed device. According to the proposed prediction model, the coefficient of flow convection increases with increase in flow velocity and decreases with increase in pipe diameter and thickness. Also, the coefficient of flow convection is largely affected by the type of pipe materials.

  • PDF

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.