• Title/Summary/Keyword: Distribution Rate

Search Result 7,051, Processing Time 0.037 seconds

Effects of Metallic Parameters for Distribution of Fatigue Crack Growth Rate - Dependence of Grain Size -; (피로크랙진전속도의 분포에 대한 금속학적 인자의 영향 - 결정입자 의존성 -)

  • Yoon, Han-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2141-2147
    • /
    • 1996
  • The strength of material is scattered owing to the inhomogenity of microstructure, in spite of the same material. Therefore, in order to design the mechanical structure with the reliability engineering, it is important to grasp the statistical nature of material strength. In this paper, effects of grain sezes for the statistical nature of the fatigue crack growth was discussed. And the statistical nature of mechanical properties was compared with the statistical nature of the fatigue crack growth rate.

A Study on Failure Rate Extraction of Power Distribution System Equipment (배전기기 고장률 추출에 관한 연구)

  • Moon, Jong-Fil;Kim, Jae-Chul;Lee, Hee-Tae;Chu, Cheol-Min;Ahn, Jae-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.366-368
    • /
    • 2007
  • In this paper, the Time-varying Failure Rate (TFR) of power distribution system equipment is extracted from the recorded failure data of Korea Electric Power Corporation (KEPCO). For TFR extraction, it is used that the fault data accumulated by KEPCO during 10 years. The TFR is approximated to bathtub curve using the exponential (random failure) and Weibull (aging failure) distribution function. In addition, Kaplan-Meier estimation is applied to TFR extraction because of incomplete failure data of KEPCO. Finally, Probability plot and regression analysis is applied. It is presented that the extracted TFR is more effective and useful than Mean Failure Rate (MFR) through the comparison between TFR and MFR.

  • PDF

Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate . (분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정)

  • 김영찬;유갑종;서태원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

Preparation of the Narrow-dispersed Microcapsules containing Electronic Ink : Influence of Surfactant and Stirring Rate

  • Park, Youn-Jung;Kim, Chul-Am;Suh, Kyung-Soo;Kang, Seung-Youl;Park, Soo-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.914-916
    • /
    • 2009
  • Using gelatin and acacia as wall and electronic ink as core substance, microcapsules were prepared by complex coacervation to fabricate a flexible electronic paper display. In order to obtain the microcapsules in a narrow dispersed distribution, we focus on the interfacial tension between the hydrophobic electrophoretic ink and an aqueous polyelectrolyte solution, through controlling sodium dodecyl sulphate (SDS) concentration and stirring rate. The existence of anionic surfactant of SDS not only decreases the droplet diameters, but also reduces the diameter size distribution. And, as the stirring rate is increased, the average size of microcapsule is also decreased.

  • PDF

A Method for Improving Air Distribution Performance at the Residence Ventilation System (주거 환기 시스템의 공기 분배 성능 개선 방안)

  • Park, Eun-Jun;Kim, Yong-Bong;Na, Hee-Hyoung;Lee, Sang-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

Testing of Poisson Incidence Rate Restriction

  • Singh, Karan;Shanmugam, Ramalingam
    • International Journal of Reliability and Applications
    • /
    • v.2 no.4
    • /
    • pp.263-268
    • /
    • 2001
  • Shanmugam(1991) generalized the Poisson distribution to capture a restriction on the incidence rate $\theta$ (i.e. $\theta$$\beta$, an unknown upper limit), and named it incidence rate restricted Poisson (IRRP) distribution. Using Neyman's C($\alpha$) concept, Shanmugam then devised a hypothesis testing procedure for $\beta$ when $\theta$ remains unknown nuisance parameter. Shanmugam's C ($\alpha$) based .results involve inverse moments which are not easy tools, This article presents an alternate testing procedure based on likelihood ratio concept. It turns out that likelihood ratio test statistic offers more power than the C($\alpha$) test statistic. Numerical examples are included.

  • PDF

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

The Effect of E-Business on Firm's Growth and Profitability in the Distribution Industry (e-비즈니스의 유통기업 성장성 및 수익성 기여 효과분석)

  • Baek, Chul-Woo
    • Journal of Distribution Science
    • /
    • v.15 no.1
    • /
    • pp.123-130
    • /
    • 2017
  • Purpose - This research aims to examine the effect of e-business adoption on firm's growth and profitability in the distribution industry. The value added from the distribution industry acts as the cost of other industries. As the distribution industry develops, its stage becomes shorter and the distribution margin becomes smaller. Therefore, e-business is expected to have a different effect on the distribution industry than other industries. Research design, data and methodology - The previous research generally used e-business adoption as an independent variable and firm's performance as a dependent variable. This study elaborated the model using a dynamic panel model that includes the performance variable of the previous year as an independent variable. By employing system GMM (Generalized Method of Moments), the endogeneity problem in the dynamic panel model can be solved. For the analysis, I extracted the distribution companies as the raw data in the National Statistical Office's Business Activity Survey over the period 2006 to 2012. Results - The growth rate of firms adopting e-business was 0.299%p higher than that of the non-adopter. However, only ERP (Enterprise Resource Planning), KMS (Knowledge Management System) and SCM (Supply Chain Management) contributed positively to the growth rate. In the case of profitability, it was 0.04%p higher than the distribution companies that did not adopt e-business. ERP and LMS (Learning Management System) improve profitability, while SCM reduces profitability. Consequently, while ERP improves both growth and profitability, SCM improves growth but reduces profitability. In addition, KMS improves firm's growth only, and LMS does only profitability, showing that each e-business has a differentiated effect. Conclusions - Since the distribution industry has different characteristics from manufacturing and other service industries, the introduction of e-business may not guarantee the growth and profitability of distribution companies. Careful introduction considering the characteristics of the distribution industry is required. In particular, it is necessary to select an e-business meeting the characteristics and needs of a distribution company, and thereafter, it is required for the company's own efforts to internalize it within the system.

Uniformity Analysis of Unmanned Aerial Application with Variable Rate Spray System (무인항공 변량방제 시스템의 살포 균일도 분석)

  • Koo, Young Mo;Bae, Yeonghwan
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.111-125
    • /
    • 2018
  • In this study, we evaluated the uniformity of deposition rate and particle size distributions of the variable rate application technique using the unmanned rotorcraft by measuring the spray pattern according to path location in the range of spraying flight. The coefficient of variation (CV) of the lateral coverage rate for the overlapped distribution with the spray swath of 3.6 m in both guidance and auto-pilot flight modes maintaining constant flight speed was about 30% and the CV of the coverage rate by the flight path location was extremely small. Therefore, it was assessed that the variable rate application technology compensating for the variation of ground speed was superior in terms of spray uniformity. In addition, the droplet size distributions in both volume median diameter(VMD) and number median diameter(NMD) were adequate for aerial application and uniform in terms of lateral distribution. Thereafter, we intend to contribute to a precise application on small-scaled fields using the unmanned agricultural rotorcraft by the variable rate application.

A Statistical Analysis of Fatigue Crack Growth under Constant-Amplitude Loads (일정진폭하중하의 피로균열전파의 통계적 특성)

  • Jeong, Hyeon-Cheol;Lim, Young-Kyu;Kim, Seon-Jin
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.104-109
    • /
    • 2002
  • In this paper, a statistical analysis of fatigue crack growth behavior under constant amplitude loads has been carried out. Fatigue crack growth tests were conducted on sixteen pre-cracked compact tension (CT) specimens of the pressure vessel (SPV50) steel in controlled identical load and environmental conditions. The assessment of the statistical distribution of fatigue crack growth experimental data obtained from SPV50 steel was studied and also the correlation of the parameter C and m in the Paris-Erdogan law was discussed. The probability distribution function of fatigue crack growth life seems to follow the 3-parameter Weibull. The fatigue crack growth rate seems to follow the 3-parameter Weibull and the log-normal distribution. The coefficient of variation (COV) of fatigue crack growth life was observed to decrease as the crack grows. A strong negative linear correlation exists between the coefficient C and the exponent m in Paris model. Fatigue crack growth rate data shows a normal distribution for both m and logC.

  • PDF