• Title/Summary/Keyword: Distribution Control Center

Search Result 685, Processing Time 0.027 seconds

Analysis the Reliability of Multilayer Ceramic Capacitor with inner Ni Electrode under highly Accelerated Life Test Conditions

  • Yoon, Jung-Rag;Lee, Kyung-Min;Lee, Serk-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.5-8
    • /
    • 2009
  • The reliability of multilayer ceramic capacitor with active thin dielectric layer was investigated by highly accelerated life test at various stress condition. The distribution of multilayer ceramic capacitor failure times is plotted as a function of time from Weibull distribution function. According to the test result, voltage acceleration factor is obtained from 2.24 to 2.96. The acceleration by temperature is much higher than other values of active thick dielectric layer. It is clear that median time to failure is affected by the stress voltage for high volumetric efficiency ceramic capacitors with active thin dielectric layer. The degradation under stress of voltage involves electromigration and accumulation of oxygen vacancy at Ni electrode interface of cathode.

Development of a Foot Pressure Distribution Measuring Device for Lower Limb Rehabilitaion

  • Choi, Junghyeon;Seo, Jaeyong;Park, Jun Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • It is important to train lower limb muscle strength using a tilting table to recover the lower extremity function of hemiplegia patients. It is known that the foot deformity and poor posture of hemiplegia patients can reduce the effectiveness of lower limb rehabilitation training. In this study, we developed a sensor system that can measure the foot pressure distribution of the patients for the load control of the lower extremity during lower limb rehabilitation training and it can be substituted for conventional high-cost technologies.

  • PDF

Demonstration of Voltage Control of DC Distribution System Using Real-time DC Network Analysis Applications (실시간 DC 계통해석 응용프로그램을 이용한 DC 배전망 전압제어 실증 연구)

  • Kim, Hong-joo;Cho, Young-pyo;Cho, Jin-tae;Kim, Ju-yong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.275-286
    • /
    • 2019
  • This paper presents real-time Direct Current (DC) network analysis applications for operation of DC distribution system or DC microgrid. These applications are installed on central Energy Management System (EMS) and provide solutions of DC network operation. To analysis DC distribution network, this paper proposes composition and sequence of applications. Algorithm of applications is presented in this paper. Demonstration tests are performed on DC distribution site in Gochang Power Testing Center of Korea Electric Power Corporation (KEPCO). To verify the performance, developed DC applications installed on EMS. Scenarios for demonstration test of voltage control are presented. Finally, measured data, application output data and simulation data (by PSCAD/EMTDC) are compared and analyze accuracy of applications.

Introduction of Acquisition System, Processing System and Distributing Service for Geostationary Ocean Color Imager (GOCI) Data (정지궤도 해색탑재체(GOCI) 데이터의 수신.처리 시스템과 배포 서비스)

  • Yang, Chan-Su;Bae, Sang-Soo;Han, Hee-Jeong;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Han, Tai-Hyun;Yoo, Hong-Rhyong
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.263-275
    • /
    • 2010
  • KOSC(Korea Ocean Satellite Center), the primary operational organization for GOCI(Geostationary Ocean Color Imager), was established in KORDI(Korea Ocean Research & Development Institute). For a stable distribution service of GOCI data, various systems were installed at KOSC as follows: GOCI Data Acquisition System, Image Pre-processing System, GOCI Data Processing System, GOCI Data Distribution System, Data Management System, Total Management & Control System and External Data Exchange System. KOSC distributes the GOCI data 8 times to user at 1-hour intervals during the daytime in near-real time according to the distribution policy. Finally, we introduce the KOSC website for users to search, request and download GOCI data.

Impact of the Anterior-Posterior Slope Types of the Scapulae on the Pressure Distribution of the Plantar Surface of the Foot

  • Lee, Juncheol;Kim, Myungchul;Moon, Sora
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.4
    • /
    • pp.1-9
    • /
    • 2017
  • Purpose : This study was conducted among 195 adults in their 20s. To analyze the impact of the slope types of the scapulae on the plantar surface of the foot, the average pressure (AP), the maximum pressure (MP), the average of local distribution values, and the average movement of the center of pressure (COP) of the different slope types of the scapulae were compared. Method : The anterior-posterior slopes of the scapulae were measured by comparing the slopes of the left and right sides of the scapulae based on the differences in the height and the slope of the coracoid process and the angulus inferior scapulae. Those whose left side of the scapulae had an anterior slope were categorized as type 1, and those whose right side of the scapulae had an anterior slope, as type 2. The average plantar pressure, the center of plantar pressure, the maximum plantar pressure, and local distribution values were analyzed using a plantar pressure analyzer of the FSA. Result : In terms of the AP of the left and right feet, there was no statistically significant difference both in types 1 and 2 on the left and right feet. The comparison results of the MP and the average of local distribution values of the two slope types of the scapulae showed that there was no statistically significant difference on the X-axis both in types 1 and 2 on the left and right feet, but that there was a large statistically significant difference on the Y-axis both in types 1 and 2. That is, the MP of the right foot of the left anterior slope type was located more on the hindfoot than that of the right anterior slope type, and the MP of the left foot of the left anterior slope type was located more on the hindfoot than that of right anterior slope type. Conclusion : This study can be used as fundamental data to predict differences in the location and size of the COP and changes in plantar pressure distribution depending on the slope types of the scapulae, and control the distribution for therapeutic purposes.

A Novel Photovoltaic Power Generation System including the Function of Shunt Active Filter

  • Park, Minwon;Seong, Nak-Gueon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.103-110
    • /
    • 2003
  • With significant development of power electronics technology, the proliferation of nonlinear loads such as static power converters has deteriorated power quality in power transmission and distribution systems. Notably, voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many countries. Many photovoltaic power generation systems installed in building systems have harmonics that are the worst object for distribution systems as a utility interactive system, and it tends to spread out continuously. Proposed and implemented in this paper is a multi-function inverter control strategy that allows a shunt active filter function to the power inverter of the photovoltaic power generation system established on a building system. The effectiveness of the proposed system is demonstrated through the simulation of a hypothetical power system using PSCAD/EMTDC.

Torque Ripple Minimization in Switched Reluctance Motor Drives Considering Magnetic Saturation (자기포화를 고려한 SRM의 토크리플 저감 제어)

  • Kang, Junho;Kim, Jaehyuck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.48-54
    • /
    • 2014
  • This paper discusses study of torque ripple minimization employing an improved TDF(torque distribution function)-based instantaneous torque control to reduce acoustic noise and vibration problem of the SRM. As the flux linkage of the SRM is a nonlinear function of phase current and rotor position, design of optimal controller for the SRM is quite complicated. Hence, an accurate mathematical model considering the nonlinearity of the SRM is required. An improved TDF based torque control has been proposed in order to reduce the toque ripple at high speed operation. Dynamic simulation using Matlab/Simulink as well as Finite Element Analysis is presented. A prototype SRM for electric vehicle traction has been manufactured to validate the experimental results comparing the dynamic simulation results.

Thickness Control of Electroplating Layer for Copper Pillar Tin Bump (구리기둥범프 용 전해도금 층 제어)

  • Moon, Dae-Ho;Hong, Sang-Jeen;Park, Jong-Dae;Hwang, Jae-Ryong;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.903-906
    • /
    • 2011
  • The electroplating and electro-less plating methods have been applied for the high density chip interconnect of the Copper Pillar Tin Bump (CPTB) preparation. The CPTB was prepared, which had been electroplated about $100{\mu}m$ pitch of copper layer firstly, and then the Tin layer was deposited on the copper pillar surface to protect the oxidation of it. It was also very important to get uniform thickness of electroplated copper layer, though it was difficult and sensitive. In order to control the thickness distribution, it was examined that the current separating disk of Insulating Gate with a hole in the center was installed between electrodes. The current flows through the center hole of the Insulating Gate in the cylindrical electroplating bath and the other parts were blocked to protect current flowing. The main current flowed through the center hole of the Insulating Gate directly to the opposite electrode of wafer disk. As the results, it was verified that the copper layer was thick in the center part of wafer disk with distribution of thinner to the outer part toward edge.

  • PDF

No Association between Copy Number Variation of the TCRB Gene and the Risk of Autism Spectrum Disorder in the Korean Population

  • Yang, So-Young;Yim, Seon-Hee;Hu, Hae-Jin;Kim, Soon-Ae;Yoo, Hee-Jeong;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.8 no.2
    • /
    • pp.76-80
    • /
    • 2010
  • Although autism spectrum disorder (ASD) has been thought to have a substantial genetic background, major contributing genes have yet to be identified or successfully replicated. Immunological dysfunction has been suggested to be associated with ASD, and T cell-mediated immunity was considered important for the development of ASD. In this study, we analyzed 163 ASD subjects and 97 normal controls by genomic quantitative PCR to evaluate the association between the copy number variation of the 7q34 locus, harboring the TCRB gene, and ASDs. As a result, there was no significant difference of the frequency distribution of TCRB copy numbers between ASD cases and normal controls. TCRB gene copy numbers ranged from 0 to 5 copies, and the frequency distribution of each copy number was similar between the two groups. The proportion of the individuals with <2 copies of TCRB was 52.8% (86/163) in ASD cases and 57.1% (52/91) in the control group (p=0.44). The proportion of individuals with >2 copies of TCRB was 11.7% (19/163) in ASD cases and 12.1% (11/91) in the control group (p=0.68). After the effects of sex were adjusted by logistic regression, ORs for individuals with <2 copies or >2 copies showed no significant difference compared with the diploid copy number as reference (n=2). Although we could not see the positive association, our results will be valuable information for mining ASD-associated genes and for exploring the role of T cell immunity further in the pathogenesis of ASD.

Development of surface defect inspection algorithms for cold mill strip (냉연 표면흠 검사 알고리듬 개발에 관한 연구)

  • Kim, Kyoung-Min;Park, Gwi-Tae;Park, Joong-Jo;Lee, Jong-Hak;Jung, Jin-Yang;Lee, Joo-Kang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • In this paper we suggest a development of surface defect inspection algorithms for cold mill strip. The defects which exist in a surface of cold mill strip have a scattering or singular distribution. This paper consists of preprocessing, feature extraction and defect classification. By preprocessing, the binarized defect image is achieved. In this procedure, Top-hit transform, adaptive thresholding, thinning and noise rejection are used. Especially, Top-hit transform using local min/max operation diminishes the effect of bad lighting. In feature extraction, geometric, moment and co-occurrence matrix features are calculated. For the defect classification, multilayer neural network is used. The proposed algorithm showed 15% error rate.

  • PDF