• 제목/요약/키워드: Distributed Generation(DG)

검색결과 162건 처리시간 0.027초

Power Flow Control of Grid-Connected Fuel Cell Distributed Generation Systems

  • Hajizadeh, Amin;Golkar, Masoud Aliakbar
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.143-151
    • /
    • 2008
  • This paper presents the operation of Fuel Cell Distributed Generation(FCDG) systems in distribution systems. Hence, modeling, controller design, and simulation study of a Solid Oxide Fuel Cell(SOFC) distributed generation(DG) system are investigated. The physical model of the fuel cell stack and dynamic models of power conditioning units are described. Then, suitable control architecture based on fuzzy logic and the neural network for the overall system is presented in order to activate power control and power quality improvement. A MATLAB/Simulink simulation model is developed for the SOFC DG system by combining the individual component models and the controllers designed for the power conditioning units. Simulation results are given to show the overall system performance including active power control and voltage regulation capability of the distribution system.

분산전원의 배전계통 연계 시 발생하는 고조파에 관한 연구 (A Study on the Harmonics of Distribution Power System Interconnected with Distributed Generation)

  • 박재균;김진성;오용택
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.73-78
    • /
    • 2010
  • 본 연구에서는 분산전원이 연계된 배전계통에서 발생하는 고조파를 평가하고자 PSCAD/EMTDC를 이용하여 분산전원 배전계통 연계 시의 시뮬레이션을 수행하였다. 실계통과 유사한 배전계통 및 태양광발전 시스템을 모델링하여 연계지점을 구간마다 시뮬레이션을 수행하였다. 고조파 연계기준(IEEE Std 1547과 IEEE Std 519)을 적용하여 알고리즘을 작성하고, 시뮬레이션 데이터는 FFT로 변환하여 THD와 TDD로 구분하여 평가하였다. 구간별로 구분하여 평가한 고조파 함유량은 분산전원을 연계하지 않은 상태와 각 구간과 Case 별로 구분하여 평가하여 연계하기 전과 비교하여 고조파를 파악한 결과 모든 배전계통의 구간에서 고조파 분포가 적합하다는 평가를 할 수 있었으며, 부하로 선정한 50kW 유도모터의 특성으로 인해 구간 2에서의 고조파 분포가 증가함으로서 연구 결과의 효용성을 입증할 수 있었다.

마이크로 가스터빈 발전시스템 운전신뢰성평가 (Evaluation of Operation Reliability for Micro Gas Turbine(MGT) Power Generation System)

  • 김재훈;허광범
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.448-455
    • /
    • 2007
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. This paper describes the procedures and results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of MGT was developed, so that it will be able to analyze or propose new distributed generation system using MGT. The field test was conducted in order to respond to a wide variety of needs for noise reduction and utilization and its performance was evaluated in consideration of its operational problems. The MGT is successfully supplying electricity to Korean grids with satisfying various regulations. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

An Integrated Compensation Algorithm for PCC Voltage Fluctuation and Unbalance with Variable Limit of Positive and Negative Sequence Currents

  • Im, Ji-Hoon;Song, Seung-Ho;Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.751-760
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation algorithm using a current limitation strategy for use in distributed generation (DG). The proposed strategy maintains the PCC voltage by prioritizing currents when an output current reference is larger than the current capacity of the power condition system (PCS) of the DG. With this strategy, the DG outputs the active current, reactive current, and the negative sequence current. The DG uses the reactive current for maintaining the PCC voltage within a normal range; the negative sequence current is used for reducing the PCC voltage unbalance. The proposed method was verified using PSIM simulation and experimental results.

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

Seamless Transfer를 위한 계통연계형 인버터의 간접전류 제어기법 (Indirect Control of Utility Interactive Inverter for Seamless Transfer)

  • 유태식;최세완;김효성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.329-332
    • /
    • 2005
  • Distributed generation (DG) systems fall in islanding operation when they still in operation even when the main grid is out of electric power Islanding operation is further classified into intentional islanding and unintentional islanding operations. In intentional islanding operation, the DG backs up critical loads while it separates from the main grid on islanding detection. Intentional islanding operation increases utilization of the DG system during the islanding operation. This paper proposes reasonal inverter topology and its control algorithm for seamless transfer of DG systems in intentional islanding operation.

  • PDF

분산전원 도입시 운영전략을 고려한 계통 신뢰도 분석 (Reliability of Power System Included Distributed Generation Considering Operating Strategy)

  • 김진오;배인수
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.81-86
    • /
    • 2003
  • 피크용 분산전원은 계통의 전체 운영비용을 줄일 수 있고, 대기용 분산전원은 수용가의 신뢰도를 향상시킬 수 있다. 피크용 분산전원과 대기용 분산전원은 해석하는데 있어서 다른 모델링을 세워야 하고 그에 따라 다른 방식으로 해석해야 하는데 이를 구현하기 위해서는 Monte-Carlo시뮬레이션 기법이 적합하다고 할 수 있다. 본 논문에서는 순차적 시뮬레이션 기법을 통해 두 가지 분산전원의 영향을 신뢰도 지수로 표현하고 이를 통해 두 가지 분산전원의 장단점을 살펴보도록 하겠다.

분산전원을 고려한 재폐로 기법 (A Reclosing Technique considering the Distributed Generation)

  • 서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.270-271
    • /
    • 2006
  • This paper presents the reclosing algorithm considering the DG(Distributed Generation). The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Extended Equal-Area Criterion), calculation of optimal reclosing time and reconnection algorithm. The simulation is implemented for the three different DG technologies by using EMTP MODELS.

  • PDF

마이크로 가스터빈 열병합 발전시스템 성능평가 (Performance Test of MGT Combined Heat & Power System)

  • 허광범;박정극;임상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF