• Title/Summary/Keyword: Distance protection

Search Result 525, Processing Time 0.033 seconds

A Probabilistic Approach to the Protection Capability Evaluation of Distance Relay in Transmission Systems

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.407-414
    • /
    • 2010
  • This paper proposes a probability measure for the evaluation of relay performance from two aspects, namely, correct trip and no-unwanted trip. They are developed based on the relationship between relay settings and relay measurements, which follow a Gaussian probability model. The proposed method based on strict mathematical derivation is applied to protection capability evaluation of distance relays under various settings. Considering the specific attributes of each protection zone, the optimal settings are also determined accordingly. The protection capability could demonstrate clearly the relay performance under various settings and the optimal settings could provide good references for engineering applications.

A Distance Protection Algorithm for a Transmission Line to Interconnect a Wind Farm to a Utility System (풍력발전단지 연계 전용선로 보호용 거리계전 알고리즘)

  • Kwon, Y.J.;Kang, S.H.;Choi, D.M.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.516-518
    • /
    • 2005
  • This paper presents a distance protection algorithm a lied to the linked line for interconnecting wind farm with the utility. The capacity of wind farm is lower than utility system and its fault current level is very low. When a high resistance fault occurs in the linked line, it is difficult to detect accurate fault distance because of reactance effect. By using the characteristic of equivalent source impedance of induction generator which is compensated by capacitor bank and characteristic of the capacity of wind farm, this paper proposes improved distance protection algorithm applied to the linked line. A series of PSCAD/EMTDC simulation results have shown effectiveness of the proposed algorithm.

  • PDF

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

Application Analysis for Loss of Excitation Relay of Generator Protection (발전기 보호용 계자상실 계전기의 적용 분석)

  • Oh, Yong-Taek;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.322-326
    • /
    • 2014
  • Recently, the LOE(loss of excitation) incidents are occurred in domestic synchronous generator frequently, the synchronous generator protection system has been much attention for the LOE protection of the incidents that threats synchronous generators and power systems. This paper was showed the characteristics and practices of distance relay that widely used LOE protection relaying in generator. Firstly, the operating characteristics and the impedance locus for LOE of the generator protection were introduced. Even if the conventional simulation program is used for modeling, but it is difficult to implement a LOE modeling and simulation of synchronous generator. So, the LOE relay operation data collected from thermal power plant and nuclear power plant in real fields were analyzed. By reviewing the applications of GE Mho relays, the reliability of LOE for synchronous generator protection in domestic were improved.

Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line (FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선)

  • Lim Jung-Uk;Runolfsson Thodur
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.

Study on Compatibility between ISM Equipment and WLAN (ISM 기기와 무선랜의 양립성에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Cho, Ju-Phil;Min, Kyoung-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.63-67
    • /
    • 2011
  • This paper analyzes the interference effect of ISM(Industrial Scientific Medical) equipment on WLAN in order to protect WLAN in interference environment which WLAN Station is close to ISM equipment. CISPR(International Special Committee on Radio Interference) radiation limit standard was used for interfering power of ISM equipment. Then, MCL(Minimum Coupling Loss) which is for the worst case and MC(Monte Carlo) which is based on statistic interference probability are used to get protection distance. As a result, the protection distance of 105 m was calculated by using MCL for the worst case. And, the protection distance of 17 m was calculated by using MC for statistic analysis.

Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments (공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가)

  • Lee, Ki-Hong;Kang, Moo-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

Protection Distance Calculation Between Inductive Systems and Radiocommunication Services Using Frequency Below 30 MHz (30 MHz 이하에서 무선 서비스와 유도성 시스템 간의 보호 거리 산출)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Park, Seung-Keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1211-1221
    • /
    • 2012
  • This paper describes separation distance to protect radiocommunication services from the interference of inductive systems using frequencies below 30 MHz for the co-existence between radiocommunication services and inductive systems. For the analysis, the interference scenario model is proposed between inductive system and radiocommunication services. Then the calculation method of protection distance is suggested by comparing the radiation power of inductive system with the allowable interference level of victim services, radiocommunication services, according to the applied propagation model. Also, the protection distance for protecting radiocommunication services in the 30 MHz below is calculated through the interference analysis from RFID(Radio Frequency IDentification) and PDP(Plasma Display Panel) TV based on the suggested method. The proposed calculation method was adopted as ITU-R recommendation in related with resolution 63 at ITU-R SG(Study Group) 1 meeting in June, 2012. It will be available to use for the protection of radiocommunication services from the interference of wireless power transfer system and power line telecommunication system.

Simulation Method on the Protection Effects of Voltage-Limiting Type SPDs Associated with the Protective Distance (보호거리에 따른 전압제한형 SPD의 보호효과에 대한 시뮬레이션기법)

  • Lee, Bok-Hee;Kim, You-Ha;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a method of simulating the protection effects of surge protective devices(SPDs) depending on the protective distance and types of input impedance of load to be protected. In order to analyze the protective performances of voltage-limiting type SPDs associated with the reflection and oscillation phenomena, the terminal voltage across load being protected and the residual voltage of SPDs were simulated by using EMTP model as functions of the protective distance and types of input impedance of loads. As a consequence, SPDs should be installed by taking into account the protective distance and input impedance of loads to achieve reliable protection of electrical and electronic equipment from lightning and switching surges. It is expected that the simulation method proposed in this paper could be practically used in design for installing SPDs in low-voltage distribution systems.