• 제목/요약/키워드: Displacement based Seismic design

검색결과 300건 처리시간 0.027초

2차원 철골 구조물의 최적 성능기반 내진설계법 개발 (Development of the Optimal Performance Based Seismic Design Method for 2D Steel Moment Resisting Frames)

  • 권봉근;이현국;권윤한;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.636-643
    • /
    • 2005
  • Recently, performance based seismic design (PBSD) methods have been suggested in numerous forms and widely studied as a new concept of seismic design. The PBDSs are far from being practical method due to complexity of algorithms resided in the design philosophy. In this paper, optimal seismic design method based on displacement coefficient method (DCM) described in FEMA 273 is developed. As an optimizer simple genetic algorithms are used for implementations. In the optimization problem formulated in this Paper, strength design criteria stiffness design criteria, and nonlinear response criteria specified in DCM are included in design constraints. The optimal performance based design(OPBD) method is applied to seismic design of a 3-story two-dimensional steel frame structures.

  • PDF

An Estimate of the Yield Displacement of Coupled Walls for Seismic Design

  • Hernandez-Montes, Enrique;Aschheim, Mark
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.275-284
    • /
    • 2017
  • A formula to estimate the yield displacement observed in the pushover analysis of coupled wall lateral force-resisting systems is presented. The estimate is based on the results of an analytical study of coupled walls ranging from 8 to 20 stories in height, with varied amounts of reinforcement in the reinforced concrete coupling beams and walls, subjected to first-mode pushover analysis. An example illustrates the application of these estimates to the performance-based seismic design of coupled walls.

접합부 회전능력에 기초한 중/저층 철골모멘트골조의 내진설계 (Seismic Design of Mid-to-Low Rise Steel Moment Frames Based on Available Connection Rotation Capacity)

  • 안재권;이철호
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.715-723
    • /
    • 2007
  • 본 연구에서는 중/저층의 철골모멘트골조를 대상으로 합리적이고 실용적인 변위기반 내진설계절차를 제시하였다. 현행의 내진설계에서는 구조시스템 종별에 따라 경험적이고 획일적으로 규정된 반응수정계수를 토대로 설계가 수행되므로, 접합부가 보유한 회전능력의 적정성 여부를 검증하기가 어렵다. 본 논문에서는 실험적으로 입증된 철골모멘트골조 접합부의 가용 소성회전능력을 주요설계변수로 직접 사용하는 새로운 설계법을 제시하였다. 이 설계방안의 정립을 위해, 우선 지금까지 불분명한 관계로 남아있던 접합부의 가용 소성회전능력과 반응수정계수 사이의 관계를 합리적이고 정량적으로 정의하는 방안을 제시하였다. 이를 토대로 변위에 기반한 단계별 내진설계절차를 제시하고 비선형동적해석에 의해 방안의 타당성을 입증하였다.

Direct displacement-based seismic assessment of concrete frames

  • Peng, Chu;Guner, Serhan
    • Computers and Concrete
    • /
    • 제21권4호
    • /
    • pp.355-365
    • /
    • 2018
  • Five previously-tested reinforced concrete frames were modelled using a nonlinear finite element analysis procedure to demonstrate the accurate response simulations for seismically-deficient frames through pushover analyses. The load capacities, story drifts, and failure modes were simulated. This procedure accounts for the effects of shear failures and the shear-axial force interaction, and thus is suitable for modeling seismically-deficient frames. It is demonstrated that a comprehensive analysis method with a capability of simulating material constitutive response and significant second-order mechanisms is essential in achieving a satisfactory response simulation. It is further shown that such analysis methods are invaluable in determining the expected seismic response, safety, and failure mode of the frame structures for a performance-based seismic evaluation. In addition, a new computer program was developed to aid researchers and engineers in the direct displacement-based seismic design process by assessing whether a frame structure meets the code-based performance requirements by analyzing the analysis results. As such, the proposed procedure facilitates the performance-based design of new buildings as well as the numerical assessment and retrofit design of existing buildings. A sample frame analysis was presented to demonstrate the application and verification of the approach.

기초구조물로서 얇은 쉘 구조물의 지진응답 (Seismic Response on Thin Shell as Structural Foundation)

  • 이휘민;아지자 압둘 나살;김재열
    • 한국공간구조학회논문집
    • /
    • 제24권2호
    • /
    • pp.31-41
    • /
    • 2024
  • This study aims to investigate the seismic response of a large span thin shell structures and assess their displacement under seismic loads. The study employs finite element analysis to model a thin shell structure subjected to seismic excitation. The analysis includes eigenvalue analysis and time history analysis to evaluate the natural frequencies and displacement response of the structure under seismic loads. The findings show that the seismic response of the large span thin shell structure is highly dependent on the frequency content of the seismic excitation. The eigenvalue analysis reveals that the tenth mode of vibration of the structure corresponds to a large-span mode. The time history analysis further demonstrates, with 5% damping, that the displacement response of the structure at the critical node number 4920 increases with increasing seismic intensity, reaching a maximum displacement of 49.87mm at 3.615 seconds. Nevertheless, the maximum displacement is well below the allowable limit of the thin shell. The results of this study provide insight into the behaviour of complex large span thin shell structures as elevated foundations for buildings under seismic excitation, based on the displacement contours on different modes of eigenvalues. The findings suggest that the displacement response of the structure is significant for this new application of thin shell, and it is recommended to enhance the critical displacement area in the next design phase to align with the findings of this study to resist the seismic impact.

Optimal design of bio-inspired isolation systems using performance and fragility objectives

  • Hu, Fan;Shi, Zhiguo;Shan, Jiazeng
    • Structural Monitoring and Maintenance
    • /
    • 제5권3호
    • /
    • pp.325-343
    • /
    • 2018
  • This study aims to propose a performance-based design method of a novel passive base isolation system, BIO isolation system, which is inspired by an energy dissipation mechanism called 'sacrificial bonds and hidden length'. Fragility functions utilized in this study are derived, indicating the probability that a component, element, or system will be damaged as a function of a single predictive demand parameter. Based on PEER framework methodology for Performance-Based Earthquake Engineering (PBEE), a systematic design procedure using performance and fragility objectives is presented. Base displacement, superstructure absolute acceleration and story drift ratio are selected as engineering demand parameters. The new design method is then performed on a general two degree-of-freedom (2DOF) structure model and the optimal design under different seismic intensities is obtained through numerical analysis. Seismic performances of the biologically inspired (BIO) isolation system are compared with that of the linear isolation system. To further demonstrate the feasibility and effectiveness of this method, the BIO isolation system of a 4-storey reinforced concrete building is designed and investigated. The newly designed BIO isolators effectively decrease the superstructure responses and base displacement under selected earthquake excitations, showing good seismic performance.

Investigating the effects of span arrangements on DDBD-designed RC buildings under the skew seismic attack

  • Alimohammadi, Dariush;Abadi, Esmaeel Izadi Zaman
    • Structural Engineering and Mechanics
    • /
    • 제77권1호
    • /
    • pp.115-135
    • /
    • 2021
  • This paper focuses on examining the effects of span arrangements on displacement responses of plan-symmetric RC frame buildings designed using the direct displacement-based design (DDBD) method by employing non-linear analyses and the skew seismic attack. In order to show the desired performance of DDBD design approach, the force-based design approach is also used to examine the seismic performance of the selected structures. To realize this objective, 8-story buildings with different plans are selected. In addition, the dynamic behavior of the structures is evaluated by selecting 3, 7, and 12-story buildings. In order to perform non-linear analyses, OpenSees software is used for modeling buildings. Results of an experimental model are used to validate the analytical model implemented in OpenSees. The results of non-linear static and non-linear dynamic analyses indicate that changing span arrangements does not affect estimating the responses of structures designed using the DDBD approach, and the results are more or less the same. Next, in order to apply the earthquake in non-principle directions, DDBD structures, designed for one-way performance, are designed again for two-way performance. Time history analyses are performed under a set of artificial acceleration pairs, applied to structures at different angles. It is found that the mean maximum responses of earthquakes at all angles have very good agreement with the design-acceptable limits, while the response of buildings along the height direction has a relatively acceptable and uniform distribution. Meanwhile, changes in the span arrangements did not have a significant effect on displacement responses.

방파제의 성능기반 내진설계법 (Seismic Performance-Based Design for Breakwater)

  • 김영준;박인준
    • 한국지반공학회논문집
    • /
    • 제38권12호
    • /
    • pp.91-101
    • /
    • 2022
  • 1995년 일본에서 발생한 고베지진으로 인하여 고베항에 대규모 피해가 발생하면서, 기존 내진설계 기준의 문제점이 제기됨에 따라 기존의 유사정적해석 및 허용응력 설계법으로는 Level II(규모 6.5) 수준의 지진에 대하여 항만 구조물 설계가 불가능한 사실이 지적되어 내진설계에 있어서 성능기반 설계법의 필요성이 대두되었다. 지진이 빈번한 일본 및 미국의 경우 항만시설에 대한 가장 선진화된 설계기준을 도입하여 적용하고 있으며, 기존 내진설계기준을 성능기반설계로 전환하였다. 1999년 이후 현재까지 국내 항만내진설계법은 내진설계가 필요한 시설과 이들의 내진등급에 대한 정의가 불명확한 점에 대해 연구를 통해 필요한 시설과 내진등급에 대한 정의를 확립하고 실험적 검증을 바탕으로 국내 실정에 부합한 성능기반 내진설계법을 확립하고 있는 단계이다. 본 연구에서 개발한 방파제의 성능기반 내진설계법은 원지반의 지표면에서의 가속도 시간이력을 고속 푸리에 변환(FFT) 후 방파제의 해당성능수준별 최대허용변위에 대응한 주파수 특성을 보정해주는 필터처리를 하였고, 필터 처리된 스펙트럼을 다시 가속도 시간이력으로 역변환(IFFT) 하여 가속도 최대값을 산정함으로써 변위를 고려한 등가정적해석을 위한 수평지진계수를 산정하였다. 또한 국내 지진 수준에 맞는 방파제의 성능기반 내진설계법의 검증을 위해서 실험과 수치해석을 수행하였다.

구조성능 목표를 고려한 면진설계 (Design of Base Isolated Building Considering Performance Based Design)

  • 황기태;이현호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.700-703
    • /
    • 2004
  • The purpose of this study is to present the design methodology of base isolated buildings. To achieve the goal of this study, time-history analysis was performed with seismic performance level and recorded seismic data. From the analysis results of MDOF system, the maximum. displacement and base shear were evaluated as 25 cm and $4\%$ by the input level which is maximum velocity of 50 kine. By introducing hybrid isolation system, seismic energy can be concentrated consequently high seismic capacity of the total building is secured.

  • PDF

차세대 내진 설계 규준을 위한 계수 결정 방법 (Method of Determination of Seismic Design Parameters for the Next Generation of Design Provisions)

  • 한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.88-96
    • /
    • 1995
  • Seismic design provisions in Korea has developed based on seismic provisions in United States (e.g., ATC 3-06). Current seismic design provisions in U .S. is moving toward adopting enhanced concept for design. Federal Emergence Management Agency (FEMA) Provides the NEHRP recommended Provisions for the Development of Seismic Regulations for New Buildings which can be used as a source document for use by any interested members of the building community. Current seismic design provisions in U .S. generally use a uni-level force. These provisions can not be satisfied if the limit state design is concerned. Limit state can be defined as a state causing undesirable performance o( a structure (e .g., serviceability, ultimate, buckling, etc.). Even if there are provision for controlling drift by two levels, it is still difficult to satisfy limit states using uni-level force. Architectural Institute of Japan (AIJ) uses a hi-level forces Int seismic loadings which can satisfy serviceability and ultimate limit state. However, the seismic parameters used in AIJ guideline are basically determined by subjective manner of code committee member and professions. These parameters need to be determined based on target quantities (target reliability, target energy dissipation, target displacement, target stress level, etc.). This study develops the method to determine the sesmic design parameters based on a certain taget level. Reliability is used as a target level and load factors in ANSI/ASCE 7-88 are selected as design parameters to be determined.

  • PDF