• Title/Summary/Keyword: Disk

Search Result 5,521, Processing Time 0.046 seconds

Trend in Research and Application of Hard Carbon-based Thin Films (탄소계 경질 박막의 연구 및 산업 적용 동향)

  • Lee, Gyeong-Hwang;Park, Jong-Won;Yang, Ji-Hun;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.111-112
    • /
    • 2009
  • Diamond-like carbon (DLC) is a convenient term to indicate the compositions of the various forms of amorphous carbon (a-C), tetrahedral amorphous carbon (ta-C), hydrogenated amorphous carbon and tetrahedral amorphous carbon (a-C:H and ta-C:H). The a-C film with disordered graphitic ordering, such as soot, chars, glassy carbon, and evaporated a-C, is shown in the lower left hand corner. If the fraction of sp3 bonding reaches a high degree, such an a-C is denoted as tetrahedral amorphous carbon (ta-C), in order to distinguish it from sp2 a-C [2]. Two hydrocarbon polymers, that is, polyethylene (CH2)n and polyacetylene (CH)n, define the limits of the triangle in the right hand corner beyond which interconnecting C-C networks do not form, and only strait-chain molecules are formed. The DLC films, i.e. a-C, ta-C, a-C:H and ta-C:H, have some extreme properties similar to diamond, such as hardness, elastic modulus and chemical inertness. These films are great advantages for many applications. One of the most important applications of the carbon-based films is the coating for magnetic hard disk recording. The second successful application is wear protective and antireflective films for IR windows. The third application is wear protection of bearings and sliding friction parts. The fourth is precision gages for the automotive industry. Recently, exciting ongoing study [1] tries to deposit a carbon-based protective film on engine parts (e.g. engine cylinders and pistons) taking into account not only low friction and wear, but also self lubricating properties. Reduction of the oil consumption is expected. Currently, for an additional application field, the carbon-based films are extensively studied as excellent candidates for biocompatible films on biomedical implants. The carbon-based films consist of carbon, hydrogen and nitrogen, which are biologically harmless as well as the main elements of human body. Some in vitro and limited in vivo studies on the biological effects of carbon-based films have been studied [$2{\sim}5$].The carbon-based films have great potentials in many fields. However, a few technological issues for carbon-based film are still needed to be studied to improve the applicability. Aisenberg and Chabot [3] firstly prepared an amorphous carbon film on substrates remained at room temperature using a beam of carbon ions produced using argon plasma. Spencer et al. [4] had subsequently developed this field. Many deposition techniques for DLC films have been developed to increase the fraction of sp3 bonding in the films. The a-C films have been prepared by a variety of deposition methods such as ion plating, DC or RF sputtering, RF or DC plasma enhanced chemical vapor deposition (PECVD), electron cyclotron resonance chemical vapor deposition (ECR-CVD), ion implantation, ablation, pulsed laser deposition and cathodic arc deposition, from a variety of carbon target or gaseous sources materials [5]. Sputtering is the most common deposition method for a-C film. Deposited films by these plasma methods, such as plasma enhanced chemical vapor deposition (PECVD) [6], are ranged into the interior of the triangle. Application fields of DLC films investigated from papers. Many papers purposed to apply for tribology due to the carbon-based films of low friction and wear resistance. Figure 1 shows the percentage of DLC research interest for application field. The biggest portion is tribology field. It is occupied 57%. Second, biomedical field hold 14%. Nowadays, biomedical field is took notice in many countries and significantly increased the research papers. DLC films actually applied to many industries in 2005 as shown figure 2. The most applied fields are mold and machinery industries. It took over 50%. The automobile industry is more and more increase application parts. In the near future, automobile industry is expected a big market for DLC coating. Figure 1 Research interests of carbon-based filmsFigure 2 Demand ratio of DLC coating for industry in 2005. In this presentation, I will introduce a trend of carbon-based coating research and applications.

  • PDF

Isolation of Bacteria from Clinical Specimens in Veterinary Medical Teaching Hospital and Trend of Antimicrobial Susceptibility (대학 동물병원 임상 검체로부터 분리된 호기성 세균과 항생제 감수성 양상)

  • Park, Se-won;Seo, Kyung-won;Hwang, Cheol-yong;Youn, Hwa-young;Han, Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.7-14
    • /
    • 2004
  • Bacteria that are resistant to several different groups of antibiotics have increased during the past few years. The importance of surveillance of antimicrobial resistance is now widely recognized. Unfortunately, this development has not been documented continuously in veterinary medicine in Korea. Therefore, the clinical prevalence and trend of antimicrobial susceptibility of aerobic isolates were investigated in this study. Total 121 isolates of aerobic bacteria were isolated from clinical specimens of dogs and cats at Veterinary Medical Teaching Hospital of Seoul National University from May 2001 to October 2002. Among them, the most common isolated species was Staphylococcus spp. (48 isolates), followed by E.coli (26 isolates), Enterococcus spp. (21 isolates), Klebsiella pneumoniae (9 isolates), Streptococcus spp. (6 isolates), Enterobacter cloacae (3 isolates), Pseudomonas aeruginosa (3 isolates), Corynebacterium xerosis (2 isolates), Chryseomonas spp. (2 isolates), and Providencia stuartii (1 isolate). The susceptibility of isolates to antibiotics was determined by the disk diffusion method. Gram-positive bacterial isolates were showed high susceptibilities to amikacin, amoxacillin/clavulanate, ceftazidime, and oxacillin, while Gram-negative bacterial isolates were showed high susceptibilities to amikacin and ceftazidime. Staphylococcus spp. were showed high susceptibilities to amikacin, amoxicillin/clavulanate, ceftazidime, cephalothin, and oxacillin. Streptococcus spp. and E.coli were showed high susceptibilities to amikacin and ceftazidime. Of the 48 staphylococci, seven Methicillin Resistant staphylococci were observed (14.6%), distributed among S. auricularis (1), S. hemolyticus (2), S. sciuri (1), S. saprophyticus (1), S. warneri (2) isolates. One strain of E.coli and one strain of Corynebacterium xerosis were resistant to all antibiotics tested. And, resistance trends between the you 2000 (from July 1999 to September 2000) and 2002 (from May 2001 to October 2002) were compared. Resistance to antibiotics was increased in both Gram-positive and Gram-negative bacterial isolates (p< 0.05). The resistance rates of Staphylococcus spp., E.coli and Klebsiella pneumoniae to all antibiotics tested were also increased (p<0.05). This study investigated increasing resistance between the year 2000 and 2002 in Veterinary Medical Teaching Hospital of Seoul National University. Surveillance resistance is helpful to alert to veterinarian and select of appropriate therapy. Antimicrobial susceptibility surveillance of isolates should urgently be continued in veterinary medicine.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

COMPARISON OF THE MARGINAL LEAKAGE OF SEVERAL FILLING MATERIALS ON CLASS V CAVITIES (제오급와동(第五級窩洞) 수복(修復)에 사용(使用)되는 수종(數種) 충전재(充塡材)의 변연누출(邊緣漏出) 비교(比較))

  • Kim, Mi-Ok;Cho, Kyew-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.20-29
    • /
    • 1989
  • The purpose of the study is to evaluate the degree of the marginal leakage of class V cavities with 4 brands of esthetic filling materials by means of the dye penetration at the enamel & dentinal margins. 160 cavities of class V were prepared on the buccal & lingual surfaces of 80 extracted premolar teeth, which divided into 4 groups. The four groups of cavities were filled with Durafill$^{(R)}$-Durafill bond$^{(R)}$(KuIzer & Co GmbH), Bisfil M$^{(R)}$-Resin bond$^{(R)}$(BISCO Inc.), Silux$^{(R)}$-Scotchbond$^{(R)}$(3M Co.) and Fuji ionomer$^{(R)}$(type II, G-C Co.) each. All specimens were immersed in 2% methylene blue dye solution for 24 hours at $37^{\circ}C$ after a 30-second thermocycling at $4^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk into two parts. The results were as follows : 1. At enamel margins, the group filled with Durafill$^{(R)}$-Durafill bond$^{(R)}$, Bisfil M$^{(R)}$-Resin bond$^{(R)}$ and Silux$^{(R)}$-Scotchbond$^{(R)}$ show no significant difference each other(p>0.05), and the above groups show less marginal leakage comparing with the group filled with Fuji ionomer$^{(R)}$(p<0.01). 2. At dentinal margins, the group filled with Silux$^{(R)}$-Scotchbond$^{(R)}$ or Fuji ionomer$^{(R)}$ show less marginal leakage than that with Durafill$^{(R)}$-Durafill bond$^{(R)}$ or Bisfil M$^{(R)}$-Resin bond$^{(R)}$(p<0.01). 3. The enamel margins show less marginal leakage than dentinal margins in all the class V cavities(p<0.01).

  • PDF

Effects of Various Ventilation Systems on the Carbon Dioxide Concentration and Fruiting Body Formation of King Oyster Mushroom (Pleurotus eryngii) Grown in Culture Bottles (새송이버섯 병재배에서 환기방법이 이산화탄소 농도 및 자실체형성에 미치는 영향)

  • Lee, Hyun-Uk;Ahn, Mi-Jeong;Lee, Shin-Woo;Lee, Cheol-Ho
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.82-90
    • /
    • 2007
  • In an attempt to establish the appropriate ventilation device for the bottle culture of king oyster mushroom (Pleurotus eryngii), we investigated carbon dioxide concentration and fruiting body formation according to the various ventilation systems within the mushroom house. In addition to, the efficiency of air circulation and growth rate as well as the appearance of physiologically abnormal phenotypes during their growth stage were also evaluated. four different ventilation devices, parallel-pressure type, positive-pressure type, negative-pressure type, and positive- and negative-pressure type were applied in this study. The positive-and negative-pressure type showed the highest efficiency of air circulation as $CO_2$ concentration was 800 ppm and the level of air current was relatively low compared to the other types (the $CO_2$ concentration of parallel-pressure type was 1,400 ppm). Moreover, the stipe length, the cap diameter, yield, and general quality grown in positive- and negative type ventilation device were also better than in the other three devices though it took slightly longer period for harvesting (18.4 days) than the others (17.6, 17.9 and 18.3 days). The appearance of physiologically abnormal phenotypes such as fruiting body lump, soft rot, and brown rot were significantly decreased in positive-and negative type compared to other types, while the appearance rates were not much different for other symptoms of bacterial ooze, stipe limb and stipe bumpy. In summary, we propose that the optimal ventilation system for the bottle culture of king oyster mushroom is positive- and negative type, and this device is expected to increase the total quality as well as yield all year around.

Genotypic and Phenotypic Characteristics of Staphylococcus aureus Isolates from Lettuces and Raw Milk (상추와 원유에서 분리한 황색 포도상구균의 유전형 및 표현형 특징)

  • Jung, Hye-Jin;Cho, Joon-Il;Park, Sung-Hee;Ha, Sang-Do;Lee, Kyu-Ho;Kim, Cheol-Ho;Song, Eun-Seop;Chung, Duck-Hwa;Kim, Min-Gon;Kim, Kwang-Yup;Kim, Keun-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.134-141
    • /
    • 2005
  • To characterize genotypic and phenotypic traits of Staphylococcus aureus isolates (n = 86) from lettuces and raw milk, major virulence-associated genes and antibiotic susceptibility were detected using PCR-based methods and disk diffusion method, respectively. All isolates possessed coagulase gene and showed five polymorphism types [500 bp (2.4%), 580 bp (17.4%), 660 bp (61.6%), 740 bp (17.4%), and 820 bp (1.2%)] due to variable numbers of tandem repeats present within the gene. Two or three different loci of hemolysin gene family were dominant in isolates, 47 of which (55%) possessed combination of hla/hld/hlg-2 genes as the most prevalent types. Among enterotoxin-encoding genes, sea was detected from 32 isolates (37%), sed from 1 isolate (1%), and sea and sed genes were co-detected from 4 isolates (5%), whereas seb, sec, and tsst-1 genes were not detected. All isolates were susceptible to ciprofloxacin, trimethoprim/sulfamethoxazole, oxacillin, and vancomycin, 85 isolates (99%) to penicillin G, 54 isolates (63%) to chloramphenicol, 51 isolates (59%) to erythromycin, and 7 isolates (8%) to clindamycin. Among resistant isolates, seven displayed multiantibiotic-resistance against two different antibiotics.

Electrochemical properties of $Gd_{0.8}Ca_{0.2}Co_{1-x}Fe_xO_3$ cathodes for medium-temperature SOFC (중간온도형 고체산화물 연료전지의 양극재료로서 $Gd_{0.8}Ca_{0.2}Co_{1-x}Fe_xO_3$의 전기화학특성)

  • Ryu Ji-H.;Jang Jong-H.;Lee Hee-Y.;Oh Seung-M.
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • For the purpose of finding new cathode materials for medium-temperature $(700\~800^{\circ}C)$ solid oxide fuel cells, $Gd_{0.8}Ca_{0.2}Co_{1-x}Fe_xO_3,\;(x=0.0\~0.5)$ are prepared, and their thermal stability and conductivity characteristics are investigated. Also, the cathodic activities are measured after the cathode layer being attached on CGO (cerium-gadolinium oxide) electrolyte disk. The X-ray analyses indicate that the materials prepared by calcining the citrate-gels at $800^{\circ}C$ have the orthorhombic perovskite structure without discernible impurities. The thermal stability of the undoped Co perovskite is so poor that it is decomposed to the individual binary oxide even at $1300^{\circ}C$. But the partially Fe-doped cobaltates exhibit a better thermal stability to retain their structural integrity up to $1400^{\circ}C$. The observation whereby both the undoped and Fe-doped cobaltates melt at ca. $1300^{\circ}C$ leads us to perform the electrode adhesion at <$1300^{\circ}C$. The cathodic activity of $Gd_{0.8}Ca_{0.2}Co_{1-x}Fe_xO_3,\;(x=0.0\~0.5)$, electrodes is superior to $La_{0.9}Sr_{0.1}MnO_3$, among the samples of $x=0.0\~0.5$, the x=0.2 cathode shows the best activity for the oxygen reduction reaction. It is likely that the Fe-doping provides a better thermal stability to the materials but in turn imparts an inferior cathodic activity, such that the optimum trade-off is made at x=0.2 between the two factors. The total electrical conductivity and ion conductivity of $Gd_{0.8}Ca_{0.2}Co_{1-x}Fe_xO_3$, are measured to be 51 S/cm and $6.0\times10^{-4}S/cm\;at\;800^{\circ}C$, respectively. The conductivity values illustrate that the materials are a mixed conductor and the reaction sites can be expanded to the overall electrode surface, thereby providing a better cathodic activity than $La_{0.9}Sr_{0.1}MnO_3$.

Characteristics of Sand-Silt Mixtures during Freezing-Thawing by using Elastic Waves (탄성파를 이용한 모래-실트 혼합토의 동결-융해 특성)

  • Kang, Mingu;Kim, Sangyeob;Hong, Seungseo;Kim, Youngseok;Lee, Jongsub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.47-56
    • /
    • 2014
  • In winter season, the pore water inside the ground freezes and thaws repetitively due to the cold air temperature. When the freezing-thawing processes are repeated on the ground, the change in soil particle structure occurs and thus the damage of the infrastructure may be following. This study was performed in order to investigate the stiffness change of soils due to the freeze-thaw by using elastic waves. Sand-silt mixtures are prepared with in the silt fraction of 40 %, 60 % and 80 % in weight and in the degree of saturation of 40 %. The specimens are placed into the square freezing-thawing cell by the temping method. For the measurement of the elastic waves, a pair of the bender elements and a pair of piezo disk elements are installed on the cell, and a thermocouple is inserted into soils for the measurement of the temperature. The temperature of the mixtures is decreased from $20^{\circ}C$ to $-10^{\circ}C$ during freezing, is maintained at $-20^{\circ}C$ for 18 hours, is gradually increased up to the room temperature of $20^{\circ}C$ to thaw the specimens. The shear waves, the compressional waves and the temperature are measured during the freeze-thaw process. The experimental result indicates that the shear and the compressional wave velocities after thawing are smaller than those of before freezing. The velocity ratio of after thawing to before freezing of shear wave is smaller than that of the compressional wave. As silt fraction increases from 40 % to 80 %, the shear and compressional wave velocities are gradually increased. This study suggests that the freezing-thawing process in unsaturated soil loosens the soil particle structure, and the shear wave velocity reflects the effect of freezing-thawing more sensitively than the compressional wave velocity.

Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT (한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가)

  • Oh, Sang-Chun;Han, Ji-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • When the mandible performs opening movement, the condyle-disk complex conducts sliding movement along the articular eminence. Thus, anatomic configuration of articular eminence is very important to normal movement of TMJ. The purpose of this study was to measure the posterior slope of the articular eminence and evaluate the effect of a pathologic bone change in the condylar head on the stiffness of articular eminence, and compare the differences of the articular eminence slope by gender and age using dental cone-beam CT. As using i-CAT Cone-Beam Computed Tomography, the CT images of 204 TMJs of 102 patients(43 men and 59 women, mean age: 37.7 years) who were diagnosed at Wonkwang University Sanbon Dental Hospital were evaluated. All images were converted into a TMJ analysis mode to observe the continuous sagittal section images and coronal section images of the joints. To observe and assess bone changes in the condyle, three dentists measured the stiffness of the articular eminence on the same images, and when two of the three dentists agreed on their reading, these results were adopted and recorded. The articular eminence slope, considering the condylar anatomic configuration, was measured in three regions, namely, lateral part, central part, and medial part of the condyle. In the cases of a normal condyle(NCBC) and a condyle(CBC) with bone change, the articular eminence slopes were $57.0^{\circ}$(NCBC) and $51.8^{\circ}$(CBC) at the medial part, $57.9^{\circ}$(NCBC) and $52.4^{\circ}$(CBC) at the central part, and $55.1^{\circ}$(NCBC) and $49.5^{\circ}$(CBC) at the lateral part of the condyle. And the articular eminence slope of the condyle with bone change demonstrated less steepness than that of normal condyle (p<0.05). The articular eminence slope showed mediolaterally that it was the steepest at the central, followed by at the medial, and at the lateral (p<0.05). There were no significant differences by the gender and the age (p.0.05).