• 제목/요약/키워드: Disinfection Process

검색결과 199건 처리시간 0.026초

Removal of haloacetonitrile by adsorption on thiol-functionalized mesoporous composites based on natural rubber and hexagonal mesoporous silica

  • Krueyai, Yaowalak;Punyapalakul, Patiparn;Wongrueng, Aunnop
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.342-346
    • /
    • 2015
  • Haloacetonitriles (HANs) are nitrogenous disinfection by-products (DBPs) that have been reported to have a higher toxicity than the other groups of DBPs. The adsorption process is mostly used to remove HANs in aqueous solutions. Functionalized composite materials tend to be effective adsorbents due to their hydrophobicity and specific adsorptive mechanism. In this study, the removal of dichloroacetonitrile (DCAN) from tap water by adsorption on thiol-functionalized mesoporous composites made from natural rubber (NR) and hexagonal mesoporous silica (HMS-SH) was investigated. Fourier-transform infrared spectroscopy (FTIR) results revealed that the thiol group of NR/HMS was covered with NR molecules. X-ray diffraction (XRD) analysis indicated an expansion of the hexagonal unit cell. Adsorption kinetic and isotherm models were used to determine the adsorption mechanisms and the experiments revealed that NR/HMS-SH had a higher DCAN adsorption capacity than powered activated carbon (PAC). NR/HMS-SH adsorption reached equilibrium after 12 hours and its adsorption kinetics fit well with a pseudo-second-order model. A linear model was found to fit well with the DCAN adsorption isotherm at a low concentration level.

정수처리장 내의 미세플라스틱의 유입 및 처리기술 현황에 관한 고찰 (A mini-review on microplastics in drinking water treatment processes)

  • 최병규;김지윤;최수훈
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.357-371
    • /
    • 2020
  • Microplastics have become a rising issue in due to its detection in oceans, rivers, and tap water. Although a large number of studies have been conducted on the detection and quantification in various water bodies, the number of research conducted on the removal and treatment of microplastics are still comparatively low. In the current research, the inflow and removal of microplastics were investigated for various drinking water treatment plants around the world. Addition to the investigation of filed research, a survey was also conducted on the current research trend on microplastic removal for different treatment processes in the drinking water treatment plants. This includes the researches conducted on coagulation/flocculation, sedimentation, dissolved air flotation, sand filtration and disinfection processes. The survey indicated mechanisms of microplastic removal in each process followed by the removal characteristics under various conditions. Limitations of current researches were also mentioned, regarding the gap between the laboratory experimental conditions and field conditions of drinking water treatment plants. We hope that the current review will aid in the understanding of current research needs in the field of microplastic removal in drinking water treatment.

정수처리에서 pH 저감에 의한 응집효율향상에 관한 연구 (Improving Coagulation Performance with pH Preadjustment in Drinking Water Treatment)

  • 이환;이철효;정창규;이윤진
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2003
  • This paper reports on a pilot scale comparison of PACS coagulation with and without pH preadjustment. The pH of the water was adjusted with carbon dioxide and sulfuric acid. Process performance was assessed on the basis of total organic carbon(TOC), UV absorbance, turbidity and disinfection by-product(DBP) precursors. Coagulation pH appeared to be a determining factor for maximum NOM removal. The optimum coagulation pH in order to decrease TOC and turbidity were pH 7. Preadjustment of pH 7 increased TOC removal to as much as 43, 47 percent with sulfuric acid and carbon dioxide. Moreover, coagulation at pH 7 caused a reduction in UV$_{254}$, THMFP and HAAFP compared to the baseline coagulation. For preadjustment of pH 7 with carbon dioxide, the percentage of TOC, UV$_{254}$, THMFP and HAAFP shows the reduction rate of 3.8, 0.5, 4.8, 9.4% comparing to the coagulation rendition using sulfuric acid. Acid addition to depress pH during coagulation decrease Langelier Saturation Index(LSI), potentially causing increase corrosion in water distribution systems. LSI for carbon dioxide and sulfuric acid at pH 6 was -2.3, -3.3. Therefore, carbon dioxide was more effective at controlling corrosion than sulfuric acid.

정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과 (Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment)

  • 김우항;김충환
    • 한국환경과학회지
    • /
    • 제12권3호
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

마을하수도 운영실태 및 개선방안 (A study on the management status of public small-scale sewage treatment facilities and the improvement)

  • 신대윤;배철호
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.55-64
    • /
    • 2008
  • In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.

항공기 청소 노동자의 작업 만족도 및 유해인자 조사 (Investigation of Job Satisfaction and Hazardous Factors of Aircraft Cleaning Worker)

  • 최연학;김기연
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.174-184
    • /
    • 2020
  • Objectives: The purpose of this study was to improve the working environment by identifying the work satisfaction of the cleaning workers of the aircraft and measuring and assessing the harmful factors of the cleaning process. Methods: We asked 23 cleaning companies for questionnaires and got 100 answers from 5 companies. The A-E Airline health manager has been contacted to establish a site survey schedule. The in-flight and lounge were measured using direct reading equipment. The harmful factor to be measured are noise, dust, temperature, volatile organic compound, total airborne bacteria, and total airborne bacteria. Results: Uncomfortable positions when replacing blanket, cleaning the table, and cleaning the floor have been identified as factor that reduce work satisfaction. Noise when replacing newspapers and cleaning toilets has been identified as a factor that lowers work satisfaction. Temperature and humidity were found to reduce work satisfaction during in-flight disinfection. Measurements of aircraft cabin and lounge with direct read equipment have shown that none of the items exceed the exposure criteria. Conclusions: As a result of measuring direct-reading equipment, no items exceeded the exposure criteria for each harmful factor. A clear survey of the working environment is required based on the results, and additional research is needed using personal sample measurement.

전해수의 특성에 관한 연구 (The Study of Characteristics of Electrolytic Water)

  • 이찬우;배기서
    • 한국염색가공학회지
    • /
    • 제18권6호
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.

전산유체역학을 활용한 개수로형 UV소독장비의 해석기법 연구 (Study on CFD Methodology for a Open Channel Type UV Reactor)

  • 황우철;박정규;김현수;이경혁;조진수
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.54-59
    • /
    • 2015
  • The performance of UV reactor which is used in water treatment is strongly affected by UV fluence rate and water flow in the UV reactor. Therefore, CFD tools are widely used in designing process of UV reactors. This paper describes the development of a computational fluid dynamics (CFD) methodology that can be used to calculate the performance of open channel type UV reactor used in wastewater treatment plant. All computations were performed using commercial CFD code, CFX, by considering three dimensional, steady, incompressible flow. The Eulerian-Eulerian multi-phase method were used to capture the water-air interface. The MSSS model, provided by UVCalc3D, was used to calculate the UV intensity field. The numerical predictions and calculated UV Dose were compared with experimental dataset to validate the CFD methodology. The reactor performance based on MS2 log reduction was well matched with measurements within 6%.

정수처리시 천연유기물질의 제거에 대한 급속혼화유형의 영향 (Influence of Different Mixing Types on the Removal of Natural Organic Matter in Water Treatment)

  • 김현철;유명진;이석헌
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.370-377
    • /
    • 2005
  • Dispersion of coagulant should be completed in a fraction of a second before the metal hydroxide precipitate has form. For the reason so-called pump diffusion flash mixing (PDFM) have been proposed, and PDFM is one of reasonable methods to quickly disperse the hydrolyzing metal salts. In this study, therefore, we attempt to understand the difference of removal characteristics of natural organic matter (NOM) between pump diffusion flash mixing (PDFM) and conventional rapid mixing (CRM) for coagulation in a water treatment system, and to enhance the removal of NOM through the improved mixing process. DOC and turbidity removal by PDFM higher than those by CRM, while SUVA value of water treated by PDFM was high as compared with that by CRM. Hydrophilic NOM was more effectively removed by PDFM than CRM, since charge neutralization effect increased by quick dispersion of coagulant. The DBP formation potentials due to NOM was effectively reduced by the improved mixing (i.e., PDFM) for coagulation and could be controlled through decrease in concentration of precursor rather than reduction of activity with disinfectant.

The effects of algal-derived organic matters (AOMs) and chlorinated AOMs on the survival and behavior of zebrafish

  • Se-Hyun Oh;Jing Wang;Jung Rae Kim;Yunchul Cho
    • Membrane and Water Treatment
    • /
    • 제14권3호
    • /
    • pp.141-146
    • /
    • 2023
  • Algal organic matters (AOMs) are challenging to remove using traditional water treatment methods. Additionally, they are recognized as disinfection by product (DBP) precursors during the chlorination process. These compounds have the potential to seriously harm aquatic creatures. Despite the fact that AOMs and DBPs formed from algae can harm aquatic species by impairing their cognitive function and causing behavioral problems, only a few studies on the effects of AOMs and associated DBPs have been conducted. To assess the impact of extracellular organic materials (EOMs) produced by three different hazardous algal species and the chlorinated EOMs on zebrafish, this study used fish acute embryo toxicity (FET) and cognitive function tests. With rising EOM concentrations, the embryo's survival rate and mental capacity both declined. Of the three algal species, the embryo exposed to Microcystis aeruginosa EOM exhibited the lowest survival rate. On the other hand, the embryo exposed to EOMs following chlorination demonstrated a drop in CT values in both the survival rate and cognitive ability. These findings imply that EOMs and EOMs treated with chlorine may have detrimental effects on aquatic life. Therefore, an effective EOM management is needed in aquatic environment.