• Title/Summary/Keyword: Discharge curve

Search Result 369, Processing Time 0.028 seconds

Observation and Analysis of Address and Sustain Discharges and Related Wall Voltage Characteristics AC-PDP

  • Park, Hyung-Dal;Tae, Heung-Sik;Hur, Min;Park, Soo-Ho;Yoo, Min-Son;Heo, Eun-Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.597-600
    • /
    • 2007
  • The address and sustain discharge characteristics in plasma display panels (PDPs) are investigated and compared by the optical emission spectroscopy using the ICCD and Vt close-curve analysis. The observations on the xenon (Xe) emission show that the spatial and temporal evolutions in the first sustain discharge are quite different from those in the address and the other sustain discharges. The striation found in the conventional sustain discharge doesn't occur in the first sustain discharge. These different discharge behaviors are explained by employing the Vt close-curve.

  • PDF

Development of Rating Curves Using a Maximum Likelihood Model (최우도 모형을 이용한 수위-유량곡선식 개발)

  • Kim, Gyeong-Hoon;Park, Jun-Il;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.83-93
    • /
    • 2008
  • The non-linear least squares model(NLSM) has long been the standard technique used by hydrologists for constructing rating curves. The reasons for its adaptation are vague, and its appropriateness as a method of describing discharge measurement uncertainty has not been well investigated. It is shown in this paper that the classical method of NLSM can model only a very limited class of variance heterogeneity. Furthermore, this lack of flexibility often leads to unaccounted heteroscedasticity, resulting in dubious values for the rating curve parameters and estimated discharge. By introducing a heteroscedastic maximum likelihood model(HMLM), the variance heterogeneity is treated more generally. The maximum likelihood model stabilises the variance better than the NLSM approach, and thus is a more robust and appropriate way to fit a rating curve to a set of discharge measurements.

A Study on the Modification Method of Flow Data in the Sewage System (하수관거 유량자료의 보정방법에 관한 연구)

  • Kim, Dae-Geun;Gong, Min-Geun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.495-502
    • /
    • 2003
  • In order to modify incorrect flow data in the sewage system, the method using the stage-discharge relation and hydraulic characteristic curve of sewer pipe are applied. The modified data were verified with field measured data and the infiltration analysis using the modified data was carried out. When flowrate were measured using the flow-meter in fair weather, the stage data were comparatively consistent but velocity data were very poor for the most part. Therefore, it was recommended that sewage flowrate variation characteristic curve and infiltration were computed using the modified data on the basis of stage data. Especially, in the case of using the hydraulic characteristic curve, extrapolation results of the rainy season flowrate using regression curve on the basis of the data in fair weather were also reasonable.

The Characteristics of Glow Discharge Plasma Diagnosis (글로우 방전 플라즈마 진단 특성)

  • Woo, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.372-375
    • /
    • 2009
  • We have studied on plasma diagnosis, characteristics of the glow discharge at the several different conditions of pressure, discharge current and such. The discharge onset voltage and onset current decreased as pressure increase, the general trend was nearly in agreement with the left regions of Paschen's curve. As normal glow discharge, discharge voltage was constant according to discharge current.

  • PDF

Development of Looped Rating Curve at Hwawon Station (화원 수위관측소 지점의 고리모양 수위-유량 관계곡선 작성)

  • Kang Shin-Uk;Lee Sang-Ho;Hwang Man-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.487-494
    • /
    • 2006
  • The flood discharge on the rising limb of a hydrograph at Hwawon station greatly differs from the flood discharge on the falling limb for the same stage. When there is such a big hysteresis, there can be a significant amount of errors in the rated discharge obtained from a simple rating curve. To reduce errors in rated discharges, a looped rating curve was established for Hwawon station in the Nakdong River. In order to compute the deviation between real discharges and simply rated discharges, a simple rating curve was established using the stage and discharge data from the results of a hydraulic channel routing. The relationship between the discharge deviation ${\Delta}Q$ and a product of B and ${\Delta}h/{\Delta}t$ was analysed, where B is the channel topwidth; ${\Delta}h$ is the stage increment; At is the time increment. Strong relation between ${\Delta}Q$ and $B{\Delta}h/{\Delta}t$ was found. The discharges calculated from the relationship show differences by 10 % or less for the 7 observations out of 11 observations in 1997 whose stages exceeds 7 m. The observed discharges for the stages over 9 m in 1998 also show small difference with the discharges estimated from the loop rating curve. Looped rating curve is recommended, instead of the simple rating curve to reduce the errors of rated discharges for gauging stations like Hwawon, which has relatively large loop width.

Vt Close Curve Analysis for Improving Address Discharge Characteristics in Open Dielectric Structure of AC PDP (플라즈마 디스플레이의 개방형 유전체 구조에서 기입방전특성을 향상시키기 위한 Vt 폐곡선 분석)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.179-184
    • /
    • 2014
  • The discharge characteristics of an open dielectric structure were investigated, especially such as a firing voltage and related wall voltage, compared with conventional panel structure based on the Vt close curve measurement in AC plasma display panel. While the front panel of the conventional structure in AC plasma display panel was composed of the glass, electrodes, and dielectric, the open dielectric structure could easily produce the discharge between the scan and the sustain electrodes by erasing the dielectric layer between two electrodes. As the open dielectric structure differ from the conventional structure, various problems were produced when driving with the conventional driving waveform. Especially, due to the changes in the discharge firing characteristics of the open dielectric structure between the scan and the sustain electrodes on the front panel, the conventional reset waveform including the address waveform needed to be modified. In this study, the Vt close curves were measured to compare the discharge firing voltages on three electrodes in the conventional and open dielectric structure and based on the Vt close curve analysis, the modified driving waveform suitable for the open dielectric structure was proposed.

The Influence of Xe Content on Wall Voltage Transfer Behavior

  • Baik, Bong-Joo;Choi, Kwang-Yeol;Min, Wong-Kee;Hong, Mun-Heon;Lee, Dong-Woo;Min, Byung-Kuk;Kim, Weo-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1555-1558
    • /
    • 2008
  • Various approaches were undertaken by major PDP makers in order to improve the luminous efficacy of the plasma discharge cells. There have been many reports that state that using a high Xe content PDP is one of the most promising key technologies available to improve the luminous efficacy. In the case of the higher Xe content panel, the higher address and sustain voltage were needed to drive the panel under the same reset condition. In this study, a variety of Xe content panels were investigated in order to examine wall voltage transfer behaviors. The transferred wall voltage status after addressing discharge at the same driving condition was analyzed by comparing Vt close curve of high and low Xe content panels. Through this analysis of Vt close curve difference, the driving waveform of a high Xe panel was quantitatively adjusted Under the same address voltage condition, results showed that the amount of the transferred wall voltage and Vt close curve after addressing discharge was matched for the first sustain discharge. Taking these results into consideration, we conclude that the driving waveform for different Xe content panels could be designed for the desired addressing discharge condition and the wall voltage state of the cell could be quantitatively controlled and measured through these approaches.

  • PDF

Prediction of Stage Discharge Curve and Lateral Distribution of Unit Discharge in an Arbitrary Cross Section Channel with Floodplain Vegetation (홍수터 식생을 고려한 불규칙한 단면에서의 수위-유량 곡선 및 단위유량 횡분포 예측)

  • Kim, Tae-Beom;Jang, Ji-Yeon;Shin, Jae-Kook;Choi, Sung-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.2
    • /
    • pp.157-167
    • /
    • 2011
  • A numerical model was developed to predict the stage-discharge curve and lateral distribution of unit discharge in open channels with nonuniform cross section or compound open-channels. The governing equation is the one-dimensional momentum equation based on assumptions of the steady and uniform flow conditions in the longitudinal direction and the uniform water surface elevation in a cross section. Vegetative drag force term was included in governing equation in order to reflect the effect of floodplain vegetation on the flow characteristics. Finite element method was applied to obtain the numerical solution of the governing equation. Stage-discharge curve and lateral distribution of unit discharge for a given water surface are calculated based on input data, such as the cross sectional geometry, Manning's roughness coefficient, vegetative information and longitudinal slope of channel bed. The developed model was verified by comparing the calculated results with the observed data and the results of Darby and Thorne's(1996) model and the nonlinear k-$\epsilon$ model. The verified model was applied to estimate the upstream boundary conditions in two-dimensional flow model. The numerical results using laterally distributed unit discharge were compared with those obtained using uniformly distributed unit discharge in two-dimensional flow model.

A development of rating-curve using Bayesian Multi-Segmented model (Bayesian 기반 Multi-Segmented 곡선식을 활용한 수위-유량 곡선의 불확실성 분석)

  • Kim, Jin-Young;Kim, Jin-Guk;Lee, Jae Chul;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.3
    • /
    • pp.253-262
    • /
    • 2016
  • A Rating curve is a regression equation of discharge versus stage for a given point on a stream where the stream discharge is measured across the stream channel with a stage and discharge measurement. The curve is generally used to calculate discharge based on the stage. However, the existing approach showed problems in terms of estimating uncertainty associated with regression parameters including the separation parameter for low and high flow. In this regard, this study aimed to develop a new method for the aforementioned problems based on Bayesian approach, which can better estimate the parameter and its uncertainty. In addition, this study used a Bayesian Multi-Segmented (Bayesian M-S) model which is provided a comparison between the existing and proposed scheme. The proposed model showed better results for the parameter estimation than the existing approach, and provided better performance in terms of estimating uncertainty range.

Analysis of Hydrodynamic Characteristics Apply to Nature-Friendly Stream Protection Method (자연형 호안공법을 적용한 소하천의 수리특성 분석)

  • Lee, Gang-Seuk;Park, Jong-Hwa;Yeon, Kyu-Bang
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.71-81
    • /
    • 2010
  • Stream Pilot Project, which began in May 2003 and finished in December 2003, was selected to develop effective methods applicable to nature-like streams. Stream restoration projects aim to maintain or increase ecosystem goods and services while protecting downstream and coastal ecosystems. Fields environmental monitoring such as flow discharge and precipitation were conducted along the Idong stream for amount of channel zone change in 2007. This study selected three monitoring positions to measure the water level and discharge of flowing water. A stage-discharge relation is obtained from direct discharge measurements for three stations by fitting an empirical relationship to the data set. Since discharge measures are made only for low flow conditions, a curve of discharge against stage can then be built by fitting these data with a power curve. And this study used data obtained from floodmark checkup as well as HEC-RAS model to analyze the hydrodynamic characteristics of monitoring sites. Reach-averaged hydraulic parameters for the supply reach were calculated from the small area's HEC-RAS model for Idong stream, and a HEC-RAS model used to analyze hydraulics for a period in 2007, after the stream was considered bank stabilization.

  • PDF