• 제목/요약/키워드: Discharge Test

검색결과 1,592건 처리시간 0.034초

PBD의 배수특성과 대심도 지반개량 (Discharge Capacity of PBD and Deep Soft Soil Improvement)

  • 구본효
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.585-592
    • /
    • 2002
  • Discharge capacity of PBD is the most important factor of specification items to control any product of PBD. There is no standard specification for the PBD. Because the degree of discharge capacity is related to well resistance, install depth, maximum strain etc in the field. Discharge capacity test of PBD, permeability test of filter are conducted using PBD materials used in Korea. This paper proposes the critical discharge capacity for deep PBD under condition of non well resistance based upon their test and theoretical calculation. It was found that discharge capacity more than about 10 ㎤/sec is enough to undergo designing of deep PBD without well resistance.

  • PDF

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

지반특성을 고려한 연직배수재의 통수능 시험 및 선정 (The Discharge Capacity Test & Vertical Drain Adoption Considering the Ground Condition)

  • 정헌철;신경하;정기문;허집
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.373-382
    • /
    • 2007
  • In the vertical drain method, discharge capacity is generally one of the most important factor which affect on the estimation of the drain efficiency. However, adopting the drain considering discharge capacity only is not sufficiently considered method so that systematic criteria for adoption is necessary to choose the most suitable drain. Therefore, this study represents the application method considering behavior of the ground and vertical drain which is coupled together and ground improvement efficiency analyzing various cases of discharge capacity test performed in the recent soft ground improvement projects. According to the analysis, most drains tend to satisfy the required discharge capacity. It presents that deformed shape of the drains and well resistance estimation along the ground settlement, improvement efficiency by water content ratio along the depth and shear strength obtained after ground improvement should be considered altogether with the discharge capacity to select the proper drain. Also, appropriate adoption of drain material considering the ground condition is vital through analyzing the field measured data and comparing the result of the discharge capacity test as various vertical drain materials are being constructed continuously.

  • PDF

순간방전 시험에 의한 산업용 축전지 잔존수명 분석 (Analysis of Industrial Battery lifetime Using Instantaneous Discharge Test)

  • 김종민;방선배;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.123-124
    • /
    • 2008
  • Battery is one of the emergency power. Battery reliability is a very important to keep up the minimum of building capabilities in case of interruption of electric power. Instantaneous discharge test is carried out for measuring transient voltage change(${\Delta}V$) and internal instantaneous impedance(Z), and then it is compared with discharge test results for the estimating the battery capacity. As a result, it was confirmed that the voltage change(${\Delta}V$) and the instantaneous impedance of the batteries failed in actual discharge test were higher that those of the sound batteries. Such an instantaneous discharge test can be a diagnosis of battery sound.

  • PDF

친환경배수재의 통수능 특성 평가 (Discharge Capacity of Environmentally Friendly Drains)

  • 조삼덕;김주형;정승용
    • 한국지반신소재학회논문집
    • /
    • 제4권1호
    • /
    • pp.27-36
    • /
    • 2005
  • 식물섬유에서 추출한 천연섬유를 이용하여 제작한 천연섬유배수재의 통수능을 평가하기 위해 수평배수재의 경우에는 투수시험 그리고 연직배수재의 경우에는 Delft 공대에서 개발한 통수능 시험과 교란 점토를 이용한 복합통수능 시험을 각각 수행하였다. 친환경 수평배수재에 대한 투수시험 결과 코코넛 껍질로 구성된 매트의 투수성은 모래에 비해 매우 우수한 것으로 나타났다. 또한, Delft 공대에서 개발한 통수능 시험으로 평가한 친환경 연직배수재의 통수능은 국산 플라스틱드레인보드의 통수능에 비해 매우 작은 것으로 나타났으나, 교란점토를 이용하여 실제 현장을 가깝게 모사한 복합통수능시험을 수행한 결과 친환경배수재와 플라스틱드레인보드를 설치한 지반의 침하나 간극수압 소산 양상이 서로 유사하게 나타나 친환경배수재가 배수재에 요구되는 최소통수능을 만족하는 것으로 나타났다.

  • PDF

낙동강 소유역 경지에서의 비점오염원 물질 발생 및 배출 특성 (Generation and Discharge Characteristics of Non-point Pollutants from Farmlands of Small Watershed for Nak-dong River)

  • 정용준;남광현;민경석
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.333-338
    • /
    • 2004
  • This study was carried out to investigate the generation and discharge characteristics of non-point pollutants from farmlands in Nak-dong river basin. Annual unit generation load of nitrogen and phosphorus by fertilization in the test paddy field was almost similar to those calculated by the fertilization standards of district agricultural technology center, but it was extremely higher in case of the test dry field. By comparing annual total generation load of nutrients from fertilization to the data of fertilizer marketing, the accurate forecasting of generation load of pollutants was achieved by marketing data. The annual total discharge ratio of nutrients through infiltration and overflow from the farmland of the test paddy field were 9.5% and 1.1%, respectively, and those in the test dry field were 22.0% and 0.1%, respectively. The monthly discharge load of nutrients were shown the highest proportioned to the discharge load from lands, but it showed higher in phosphorus, which was caused by the intermittent discharge of phosphorus accumulated in drainage.

실내모형시험을 통한 연직배수재의 통수능력 및 스미어존 영향 평가 (A Assessment of Discharge Capacity of Vertical Drains and Smear Zone Effect from Model Test)

  • 천병식;김의석;도종남;국길근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1136-1143
    • /
    • 2008
  • The Vertical Drains(Sand Drains, Pack Drain, PBD) is used for Vertical Drains Method in domestic. Each of the drains is selected after it consider a field condition and efficiency of drain. A discharge capacity is very important factor, which to estimate a efficiency. And the smear Zone where disturbance area of in-suit by installation of Vertical Drains is important factor to select a drains. In this study, the complex discharge capacity test was operated for discharge capacity comparison of the Wing Drain and PBD. And a model test was operated to apprehend smear zone of the Wing Drain and PBD. From these tests, it was apprehended an engineering characteristic of vertical drain. The results of the complex discharge capacity test, a discharge capacity fell below $20cm^3/sec$ to $1cm^3/sec$ in more than overburden load $2.5kg/cm^2$. The Wing Drain maintained a over $40cm^3/sec$ in more than overburden load $2.5kg/cm^2$ and minimum discharge capacity $8cm^3/sec$. The results of the smear zone test, a influence bounds of smear zone was more larger in case of the Wing Drain(rectangle) than the PBD. But when a discharge capacity of Wing Drain is considered, it was concluded which smear zone bounds difference was effected in comparison with PBD. I think that it minimized a mandrel section to minimize a smear zone effect range

  • PDF

준설매립지반의 안정처리를 위한 수평배수재의 공학적 특성 (Engineering Characteristics of Horizontal Drainage for Stabilization of Dredged Fill)

  • 이상호;박정용;장연수;박정순;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.563-570
    • /
    • 2001
  • In this study, the charactersistics of horizontal drains used to stabilize the dredged fill are investigated experimentally by doing tensile strength test, discharge capacity test, and filter clogging test. The types of the drains selected for the study are filament type (Tyre-E), embossed type(Type-P) and heat bonded cubic type with the thickness 10mm(Type-010) and 5mm(Type-05). The results of tensile strength and discharge capacity test show that the performance of drain Type-O10 was better than the other drains. This is caused by the fact that the lattice shape core of drain Type-O10 has strong rigidity and minimizes the loss of the sectional area of discharge with increased confining pressure. Analyzing the compatibility of filters by the results of the strength characteristics test and clogging test, the filter of filament type drain produced with polyester clothed polyamide performed well.

  • PDF

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

XLPE 케이블의 PD 검출 필터 시험 (Filter Test for Detecting Partial Discharge in XLPE Cable)

  • 조재철;최용성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF