Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

Estimating the Location of Partial Discharge Signals (부분 방전 신호의 위치 추정)

  • 유치형;정찬수;김재철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.80-85
    • /
    • 1997
  • Preventive diagnosis technique of power transforms is very important for highly reliable operation of power systems, and especially that of online transformer is needed in view of economy. Acoustic methods for partial discharge points have been studied abroad since 1960's in earnest. Electric-ultrasonic locating method by which partial discharges are found through detecting the electric and ultrasonic signal generated in partial discharge and ultrasonic-ultrasonic locating method by which partial discharges are found through detecting two ultrasonic signal with two ultrasonic sensor have been researched in our country. By using this ultrasonic-ultrasonic locating method, it was proposed of graphical determination technique of partial discharge points one dimension, two dimension, three dimension. But in locating partial discharges, they have assumed that the number of signal origin is one. So in this study we suggests a method of locating and knowing the number of signal origins when there are several origins by using ultrasonic-ultrasonic method.

  • PDF

An Accidental Position Detection Algorithm for High-Pressure Equipment using Microphone Array (Microphone Array를 이용한 고압설비의 고장위치인식 알고리즘)

  • Kim, Deuk-Kwon;Han, Sun-Sin;Ha, Hyun-Uk;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2300-2307
    • /
    • 2008
  • This study receives the noise transmitted in a constant audio frequency range through a microphone array in which the noise(like grease in a pan) occurs on the power supply line due to the troublesome partial discharge(arc). Then by going through a series of signal processing of removing noise, this study measures the distance and direction up to the noise caused by the troublesome partial discharge(arc) and monitors the result by displaying in the analog and digital method. After these, it determines the state of each size and judges the distance and direction of problematic part. When the signal sound transmitted by the signal source of bad insulator is received on each microphone, the signal comes only in the frequency range of 20 kHz by passing through the circuit of amplification and 6th low pass filter. Then, this signal is entered in a digital value of digital signal processing(TMS320F2812) through the 16-bit A/D conversion. By doing so, the sound distance, direction and coordinate of bad insulator can be detected by realizing the correlation method of detecting the arriving time difference occurring on each microphone and the algorithm of detecting maximum time difference.

PD Signal Time-Frequency Map and PRPD Pattern Analysis of Nano SiO2 Modified Palm Oil for Transformer Insulation Applications

  • Arvind Shriram, R.K.;Chandrasekar, S.;Karthik, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.902-910
    • /
    • 2018
  • In recent times, development of nanofluid insulation for power transformers is a hot research topic. Many researchers reported the enhancement in dielectric characteristics of nano modified mineral oils. Considering the drawbacks of petroleum based mineral oil, it is necessary to understand the dielectric characteristics of nanofluids developed with natural ester based oils. Palm oil has better insulation characteristics comparable to mineral oil. However very few research reports is available in the area of nanofluids based on palm oil. Partial discharge (PD) is one of the major sources of insulation performance degradation of transformer oil. It is essential to understand the partial discharge(PD) characteristics by collecting huge data base of PD performance of nano modified palm oil which will increase its confidence level for power transformer application. Knowing these facts, in the present work, certain laboratory experiments have been performed on PD characteristics of nano $SiO_2$ modified palm oil at different electrode configurations. Influence of concentration of nano filler material on the PD characteristics is also studied. Partial discharge inception voltage, Phase resolved partial discharge (PRPD) pattern, PD signal time-frequency domain characteristics, PD signal equivalent timelength-bandwidth mapping, Weibull distribution statistical parameters of PRPD pattern, skewness, repetition rate and phase angle variations are evaluated at different test conditions. From the results of the experiments conducted, we came to understand that PD performance of palm oil is considerably enhanced with the addition of $nano-SiO_2$ filler at 0.01%wt and 0.05%wt concentration. Significant reduction in PD inception voltage, repetition rate, Weibull shape parameter and PD magnitude are noticed with addition of $SiO_2$ nanofillers in palm oil. These results will be useful for recommending nano modified palm oil for power transformer applications.

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF

A Study on Partial Discharge Measurement using Optical Fiber Sensors (광섬유 센서를 이용한 부분방전 측정연구)

  • Lee, June-Ho;Lee, Cheol-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings (고압전동기 고정자 권선에서 부분방전 펄스의 전송)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.

Propagation Characteristics of Acoustic Signals Produced by Partial Discharges in an Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Park, Dae-Won;Cha, Sang-Wook;Cho, Hyang-Eun;Kim, Dong-Geon;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.188-188
    • /
    • 2011
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. We fabricated a decoupler and an amplifier to measure acoustic signals produced by PD. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz~1.6 MHz. After a comparative calibration by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil as a function of distance.

  • PDF

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF