• Title/Summary/Keyword: Disc shape

Search Result 194, Processing Time 0.027 seconds

A Study on the Surface Properties Test of the Grinding Disk Assembly for Crushing Materials in Secondary Cells (이차전지 원료 해쇄용 그라인딩 디스크 어셈블리 표면 특성 시험에 관한 연구)

  • Sang-Pil Han;Dong-Hyuk Lee
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2023
  • Metal raw materials and chemical additives, which are raw materials for secondary batteries, are pulverized by the high-speed rotation of the Grinding Disc of the Classifier Separator Mill (CSM). Grinding discs are required to withstand abrasion, corrosion, high-speed rotational force and impact. In order to analyze the stability of domestic and foreign grinding discs, quality tests including surface roughness, surface lubrication, surface state measurement, and surface 3D shape measurement were analyzed. When producing developed products, it shows that excellent products can be produced.

Study on Dependence of Friction Characteristics of Sintered Brake Friction Materials on Graphite Shape and Ratio with regard to Speeding up Rapid Transit System (도시철도 고속화에 대비한 금속계 소결마찰재에서의 흑연 형상 및 비율에 따른 마찰특성 연구)

  • Kim, Young Kyu;Lee, Hi Sung
    • Tribology and Lubricants
    • /
    • v.29 no.4
    • /
    • pp.242-247
    • /
    • 2013
  • This study aims to establish the fundamental basis for the design of materials used in high-speed trains, by using a lab-scale dynamometer to evaluate the characteristic behavior of metallic sintered friction materials in relation to the shape of graphite. The test results clearly demonstrate that when flake graphite and granular graphite are added equivalently, the average coefficient of friction is much lower, and it is less influenced by speed variation; moreover, friction wear is observed to be insignificantly low. Adding flake graphite increases the coefficient of friction, which leads to higher friction wear. In addition, the roughness of the disc surface was equivalent regardless of the shape of the graphite.

Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy

  • Son, Byung-Chul;Kim, Deog-Ryeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.61-64
    • /
    • 2015
  • A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.

THE CHANGE OF THE TEMPOROMANDIBULAR JOINT AFTER EXPERIMENTAL DISTRACTION OF MANDIBULAR RAMUS IN RABBIT (가토에서 하악골 신장술이 악관절에 미치는 영향)

  • Lim, Seung-Kyu;Kim, Chul-Hwan;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.543-549
    • /
    • 2008
  • Distraction osteogenesis is a commonly used technique for mandibular lengthening, but changes in the temporomandibular joint(TMJ) have not been well documented. The TMJ is one of the most complex joint in the body and is composed of a fibrous surface layer, a proliferative zone, hypertrophic cartilage, and bone. The shape and role of the TMJ change and modify during a person's life-time. Possible complications that can arise after mandibular distraction include failure of the formation, failure of callus, infection, disturbance of TMJ and of occlusion. However, there are only a few reports on changes in the TMJ as a result of distraction osteogenesis. Hence, the goal of this study was to evaluate the change of the TMJ after experimental distraction of mandibular ramus in rabbit. We studied histological changes of mandibular condyle, articular disk and retrodiscal tissue, and also examined the collagen I gene expression and MMP-1 gene expression. The results were as follows. 1. In the histological staining, experimental condylar surface showed more thick fibrous articular layer and proliferative layer, compared with the control condyle and experimental articular disc showed thick and dense collagen fibers compared with the control disc. 2. In the collagen I and MMP-1 gene RT-PCR analysis, experimental discs showed increased collagen I expression compared with the control disc, while MMP-1 gene expression was decreased compared with the control disc. The retrodiscal tissue was almost equal expressions of the collagen I and MMP-1 genes compared with the control retrodiscal tissue. These findings suggest that histological and biomolecular changes occur in condyles and discs after unilateral mandibular distraction osteogenesis.

A New Classification for Cervical Ossification of the Posterior Longitudinal Ligament Based on the Coexistence of Segmental Disc Degeneration

  • Lee, Jun Ki;Ham, Chang Hwa;Kwon, Woo-Keun;Moon, Hong Joo;Kim, Joo Han;Park, Youn-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.69-77
    • /
    • 2021
  • Objective : Classification systems for cervical ossification of the posterior longitudinal ligament (OPLL) have traditionally focused on the morphological characteristics of ossification. Although the classification describes many clinical features associated with the shape of the ossification, including the concept of spondylosis seems necessary because of the similarity in age distribution. Methods : Patients diagnosed with OPLL who presented with increase signal intensity (ISI) on magnetic resonance imaging were surgically treated in our department. The patients were divided into two groups (pure versus degenerative) according to the presence of disc degeneration. Results : Of 141 patients enrolled in this study, more than half (61%) were classified into the degenerative group. The pure group showed a profound male predominance, early presentation of myelopathy, and a different predilection for ISI compared to the degenerative group. The mean canal compromise ratio (CC) of the ISI was 47% in the degenerative group versus 61% in the pure group (p<0.0000). On the contrary, the global and segment motions were significantly larger in the degenerative group (p<0.0000 and p=0.003, respectively). The canal diameters and global angles did not differ between groups. Conclusion : Classifying cervical OPLL based on the presence of combined disc degeneration is beneficial for understanding the disorder's behavior. CC appears to be the main factor in the development of myelopathy in the pure group, whereas additional dynamic factors appear to affect its development in the degenerative group.

A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ (악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

Development of Program for Electro-Magnetic Analysis in Superconducting Bulk (초전도 벌크내의 전자장 해석 프로그램 개발)

  • 한승용;한송엽
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.85-88
    • /
    • 1999
  • The study of HTS bulk in permanent magnet applications requires the calculation of forces acting on the bulk. Currents distribution in HTS Superconducting bulk is very important to determine this forces. We have made computer program to find this current distribution and this program is applied to some simple disc-shape HTS bulk being magnetised in a uniform field. The techniques for determination of currents are FEM analysis and iteration method.

  • PDF

Inductive Sensor and Target Board Design for Accurate Rotation Angle Detection

  • Hwang, Jae-Jeong;Moon, Joon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 2017
  • In the commercial building such as huge enterprise building, more accurate operation of the center-controlled roller blind. We design, in this work, the target disc that its shape is nonlinearly changing and the sensor coils that are differentially arranged. The performance shows less than 1% accuracy when it is implemented in the roller blind.

A new object recognition algorithm using generalized incremental circle transform

  • Han, Dong-Il;You, Bum-Jae;Zeungnam Bien
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.933-938
    • /
    • 1990
  • A method of recognizing 2-dimensional polygonal object is proposed by using a concept of generalized incremental circle transform. The generalized incremental circle transform, which maps boundaries of an object into a circular disc, represents efficiently the shape of the boundaries that are obtained from digirized binary images of the objects. It is proved that the generalized incremental circle transform of an object is invariant to object translation, rotation, and size, and can be used as feature information for recognizing two dimensional polygonal object efficiently.

  • PDF

The Peculiarities of New Textile Hand Evaluation Method

  • Eugenija, Strazdiene;Matas, Gutauskas
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.414-419
    • /
    • 2006
  • The paper presents information concerning metrological and technical characteristics of KTU-Griff-Tester device, the optimization of its parameters and the cases of its application. It was defined that the behaviour of textile material during its extraction through a rounded hole depends upon its structure. Variations of geometrical shape of woven and knitted specimens can be described by mathematical expressions of shortened epicycloids and Cassini ovals. It is shown that waving process of disc shaped specimen can be predicted on the basis of the law of sine curve. The examples of textiles treatment with different types of commercial softeners are presented, herewith showing the suitability (sensitiveness) of the new device to detect the changes of textile hand. Meantime it is shown that the level of materials anisotropy can be decided on the basis of transformations of specimen's geometrical shape.