• Title/Summary/Keyword: Disaster Management Performance

Search Result 277, Processing Time 0.031 seconds

A study on characteristics of accidents involving working platforms at construction sites (건설현장 작업발판에서의 재해 특성에 관한 연구)

  • Jeong, Sung-Chun
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.89-100
    • /
    • 2014
  • Construction victims have increased year by year. Disaster proportion is also increasing continuously. Looking over the causes of disasters by each type of work, fall from working platform indicate the highest rate above all so that it is urgently required to set up safety measures. This study is to grasp the present status of construction accidents, to identify areal characteristics of the top 20% accidents on the basis of working platforms with the highest accident rate, to grasp the causes of accidents after their analyses, and to present methods to reduce casualties related to working platforms. As measures to reduce construction disasters, this study proposes to improve safety management and training on working platforms, to complement safety regulations, and to better performance including the development and expansion of certified products suitable for safety regulations.

The Influence of Emotional Labor at Seoul Management Operations Center on Job Performance : Focusing on the Mediating Effect of Social Support (서울종합방재센터 종합상황실 소방공무원의 감정노동이 조직몰입에 미치는 영향 - 사회적 지원의 매개효과를 중심으로 -)

  • Park, Chan Seok;Kim, Jin Keun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.13-25
    • /
    • 2015
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Emergency Operations Center have made improvements as the core fire operational center in Korea. However, There have been so many problems happening in the middle of receiving calls from malice citizens of Seoul. The purpose of this study is to scrutinize current operations focused on fire fighters in Seoul Emergency Operations Center and to cope with how to overcome these problem by using AMOS 21 & SPSS Statistics 21. The result of this study presents that how we can find to be Seoul Emergency Operations Center running well. And This study is applied to seoul fire policies or helped to setting them up.

A Study of Port Facility Maintenance and Decision-making Support System Development (항만시설 유지관리 의사결정 지원 시스템 개발 연구)

  • Na, Yong Hyoun;Park, Mi Yeon;Choi, Doo Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.290-305
    • /
    • 2022
  • Purpose: Currently, port facility informatization technology is focused on the planning and design phases, so the necessity of research and technology development on the port facility maintenance system based on life cycle-level information is emphasized. Method: Based on the maintenance history data of port facilities and facility operation information, from the perspective of the life cycle of port facilities, the system is configured to enable maintenance decisions for port facilities through analysis of aging patterns, performance degradation prediction models, and risk analysis and proposed a method of expressing information. Result: A function was developed to simultaneously display the SOC performance evaluation and the comprehensive performance evaluation developed in this study, so that mid-to long-term maintenance and reinforcement and facility expansion can be applied and comparatively judged. Conclusion: The integrated port performance system developed in this study induces and supports the risk minimization of port facility management by proactively promoting appropriate repair and reinforcement measures through historical and operational information on port facilities.

Conceptual Study for Risk Assessment of Asset Management of Infra Structure System (국가기반시설 자산관리위험도분석 개념 연구)

  • Park, Mi Yun;Park, Hung Ju
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.1
    • /
    • pp.43-47
    • /
    • 2012
  • The asset management of infra facilities is a total framework for finally supporting a safe and comfortable service, which includes functions of supporting evaluation of condition and performance of infrastructures, making the decision method of repair or rehabilitation of deteriorated facilities, and lengthening the life cycle of structure through the decision of adequate cost and time of repair or reinforcement. In the range of the asset management, organization, human, the target, and information & data of company are included. Therefore, in this paper, appling the method of asset management analysis to the infra structures, the process of the risk assesment using BRE (Business Risk Exposure) and the basis of consisting ORDM (Optimized Renewal Decision-Making) are expressed.

A Study on the Special Needs of the Hearing-Impaired Person for Disaster Response (청각장애인 재난대응 욕구에 관한 연구)

  • Kim, Soungwan;Kim, Hey Sung;Roh, Sungmin
    • 재활복지
    • /
    • v.21 no.2
    • /
    • pp.63-88
    • /
    • 2017
  • This study evaluated the actual status of special needs of the hearing-impaired person for disaster response. The analysis revealed a significant level of unmet needs in disaster response for hearing-impaired person. The 5 special needs in disaster response include: 1) communication needs, which involve securing the means to make an emergency rescue request and communicating information during the rescue process; 2) transportation needs, which indicate the effective evacuation capacity and the level of training; 3) medical needs, which address the degree of preparedness for physical and mental emergency measures and the delivery of health information for rescue and first aid process; 4) maintaining functional independence needs, which refer to the level of self-preparedness to minimize damage in disaster situations, and; 5) supervision needs, which correspond to a personalized support system provided to disaster-vulnerable groups.

Perception of Patient Safety Risk Factors and Performance Level of Safety Care Activities among Hospital Nurses (환자안전 위험요인에 대한 병원간호사의 인식수준과 안전간호활동 수행정도)

  • Son, Young Shin;Lee, Young Whee;Kim, Young Shin;Song, Eun Jeong;Lee, Hye Ryun;Lee, Ju Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.24 no.2
    • /
    • pp.190-200
    • /
    • 2018
  • Purpose: The purpose of this study was to identify the level of perception of safety risk factors and the degree of performance of safety nursing activities in order to develop an education program to improve the safety of patients. Methods: The subjects were 217 nurses from 3 university hospitals in Incheon. Data were collected with structured questionnaires and analyzed using descriptive analysis, t-test, and ANOVA using SPSS 22.0. Results: The level of perception of patient's safety risk factors and safety care activities was 2.93 and 4.68, respectively. Perception of patient safety risk factors which belonging to the risk type of therapeutic devices, equipment, service and infrastructure all scored below average; also in addition, behavior, performance, and violence risk type and work system, information and communication risk type showed relatively low perception levels. Safety nursing activities showed a low level of performance in accurate communication among medical teams, management of fire and disaster, security management, use of restraints, identification of patients, and correct performance of operations and procedures. Conclusion: Based on these results, it is necessary to improve the safety of patients by taking proper management measures along with education.

Seismic Evaluation of an Apartment House With a Coupling Effect of Structural and Non-Structural Walls (공동 주택의 구조벽과 비내력벽의 일체화 효과에 따른 내진 성능 분석)

  • Kim, Eun-Seo;Choi, Byung-Hoon;Lee, Jung-Han;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.85-92
    • /
    • 2019
  • This study was carried out to examine the effect of the presence of non-structural walls in apartment buildings subjected to an earthquake. It was believed that the presence of non-structural walls, which has not been considered in the structural design process, was usually built together with structural walls and this led to significant damages to the apartment buildings in Pohang earthquake, 2017. In this study, a 22-story apartment building was selected and modeled to simulate the seismic behavior due to earthquakes. The story drift, performance point, and compressive strain in the walls were the main parameters to evaluate the seismic performance with the presence of non-structural walls.

Bio-AdHoc Sensor Networks for Disaster Emergency Management Systems (재난 관리용 시스템을 위한 센서 탑재 바이오 애드 혹 네트워크)

  • Lee, Dong-Eun;Lee, Goo-Yeon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.2
    • /
    • pp.29-36
    • /
    • 2007
  • Ad hoc network does not need any preexisting network infrastructure, and it has been developed as temporal networks in the various fields. Infostation is an efficient system to transfer information which does not have delay sensitive characteristics. In this paper, we propose a disaster emergency management system using sensor attached animals' mobility combined with infostation system. We also analyze the performance of the proposed system by simulation. From the performance analysis results, we expect that the proposed system will be very useful to early detect big forest fires which occurs frequently in Korea mountain areas.

Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

  • Abdeddaim, Mahdi;Ounis, Abdelhafid;Shrimali, Mahendra K.;Datta, Tushar K.
    • Structural Engineering and Mechanics
    • /
    • v.62 no.2
    • /
    • pp.197-208
    • /
    • 2017
  • Among various retrofitting strategies, use of semi-active control for retrofitting a building structure has gained momentum in recent years. One of the techniques for such retrofitting is to connect a weaker building to an adjacent stronger building by semi-active devices, so that performances of a weaker building are significantly improved for seismic forces. In this paper, a ten storey weaker building is connected to an adjacent stronger building using magneto-rheological (MR) dampers, for primarily improving the performance of the weaker building in terms of displacement, drift and base shear. For this, a fuzzy logic controller is specifically developed by fuzzyfying the responses of the coupled system. The performance of the control strategy is compared with the passive-on and passive-off controls. Pounding Mitigation between the two buildings is also investigated using all three control strategies. The results show that there exists a fundamental frequency ratio between the two buildings for which maximum control of the weaker building response takes place with no penalty on the stronger building. There exists also a fundamental frequency ratio where control of the weaker building response is achieved at the expense of the amplification of the stronger building. However, coupling strategy always improves the possibility of pounding mitigation.

The Methods to Improve the In-Line Eductor (포소화약제 혼합장치의 개량화 방안)

  • Joo, Seung-Ho;Lim, Mann-Taek;Kim, Hye-Won;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.275-282
    • /
    • 2011
  • A core device of foam system is the in-line eductor and it is the device to mix the foam liquid into liquid solution proper to the use density and the mixture ratio must be kept regularly regardless of changing fluid condition of the front and rear end of the in-line eductor. However, if the flux of the pressurized water changes, the mixture ratio is not kept regularly, and so it becomes a cause which a performance of fire-extinguishing deteriorates in discharging foam liquid. I devise a method to improve it that the metering orifice type in-line eductor is improved into the metering venturi type in-line eductor, the fluctuation of the mixture ratio to the flux change of the pressurized water is minimized and the performance of fire-extinguishing is kept regularly. As this method is simple in its structure and can be designed at a low cost, it helps for maintenance as well. In the future, it seems to need the research for the metering nozzle type in-line eductor in the future.