• Title/Summary/Keyword: Disaster Communication

Search Result 621, Processing Time 0.023 seconds

A Study on the Communication Network Construction Marine of Safety in the country (우리나라의 해상 안전 통신망 구축에 관한 연구)

  • 오문희;신현식;박연식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.1017-1024
    • /
    • 2001
  • Is with the development which economic growth is quick to do, the transportation amount of material of the sea increases suddenly and with from the sea to be big the sea disaster which is small occurs it is like that nothing it analyzes the Communication network civil official system and that facility present condition of the sea which is more important with to research the advanced anger plan and the efficient civil official system of the domestic sea Communication network, it does to sleep.

  • PDF

Performance analysis of an adaptive OFDM over an underwater acoustic channel (수중 음향 채널에서 적응형 OFDM의 성능 분석)

  • Im, Yo-Woong;Kang, Hee-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.5
    • /
    • pp.509-515
    • /
    • 2010
  • Such as disaster rescue in deep water, undersea exploration and monitering for environmental pollution, many applications require the acoustic communication for high data rate over underwater acoustic channel. As underwater channel is very complex and is time-varying, conventional single carrier communication has good performance. In this paper, An adaptive OFDM system is analyzed for high data rate and reliability and rubust service over UWA channels. Through the adaptive system, we show threshold switching for an adaptive algorithm.

The Evaluation of UWB Wireless Communication Position Determination Function in an Enclosed Space for Fire Fighting (소방활동을 위한 밀폐공간 무선통신 측위성능 평가)

  • Kim, Dong-Hyun;Kim, Chung-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.117-122
    • /
    • 2017
  • The absence of fire fighters' connection to communication can bring about increased loss of life due to errors and delays in rescue and actions and danger to their own safety. Therefore, when communication infrastructure has been destroyed in an enclosed space, it is necessary to set up an emergency wire or wireless telecommunication environment to fire fighting and to secure safer environment to deal with the disaster by checking the location of fire fighters. In this research, for the establishment communication environment in an enclosed inside using Ultra-Wide Band (UWB) wireless communication network, the performance of communication position determination of a single UWB communication module was evaluated regarding 6 kinds of indoor surroundings. When the communication distance in an indoor environment of each 6 channels bandwidth of UWB communication frequency was measured, the results were as follows: the open space (Ave. 15.5 m, Max. 20 m), the corridor (Ave. 17.33 m, Max 20 m), inside retaining home furnishings (Ave. 15.3 m, Max. 20 m), vertical stairs (Ave. 4.33 m, Max. 6 m), horizontal space with a closed fire door (Ave. 6.5 m, Max. 17 m). It was also found out that the communication function and the distance function were best in the frequency range from 6489.6 to 1081.6 MHz by 7 Ch. Accordingly, the establishment of communication environment in an enclosed space is judged to be possible when UWB communication module is set up at 20 m apart and multiple channels are used.

A Study on Improvement of the police disaster crisis management system (경찰의 재난위기관리 개선에 관한 연구)

  • Chun, Yongtae;Kim, Moonkwi
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.556-569
    • /
    • 2015
  • With about 75% of the population of Korea criticizing the government's disaster policy and a failure to respond to large-scale emergency like the Sewol ferry sinking means that there is a deep distrust in the government. In order to prevent dreadful disasters such as the Sewol ferry sinking, it is important to secure a prime time with respect to disaster safety. Improving crisis management skills and managerial role of police officers who are in close proximity to the people is necessary for the success of disaster management. With disaster management as one of the most essential missions of the police, as a part of a national crisis management, a step by step strengthening of the disaster safety management system of the police is necessary, as below. First, at the prevention phase, law enforcement officers were not injected into for profit large-scale assemblies or events, but in the future the involvement, injection should be based on the level of potential risk, rather than profitability. In the past and now, the priortiy was the priority was on traffic flow, traffic communication, however, the paradigm of traffic policy should be changed to a safety-centered policy. To prevent large-scale accidents, police investigators should root out improper routines and illegal construction subcontracting. The police (intelligence) should strengthen efforts to collect intelligence under the subject of "safety". Second, with respect to the preparatory phase, on a survey of police officers, the result showed that 72% of police officers responded that safety management was not related to the job descriptions of the police. This, along with other results, shows that the awareness of disaster safety must be adopted by, or rather changed in the police urgently. The training in disaster safety education should be strengthened. A network of experts (private, administrative, and police) in safety management should be established to take advantage of private resources with regard to crisis situtions. Third, with respect to the response phase, for rapid first responses to occur, a unified communication network should be established, and a real-time video information network should be adopted by the police and installed in the police situation room. Fourth, during the recovery phase, recovery teams should be injected, added and operated to minimize secondary damage.

A Study on the Special Needs of the Hearing-Impaired Person for Disaster Response (청각장애인 재난대응 욕구에 관한 연구)

  • Kim, Soungwan;Kim, Hey Sung;Roh, Sungmin
    • 재활복지
    • /
    • v.21 no.2
    • /
    • pp.63-88
    • /
    • 2017
  • This study evaluated the actual status of special needs of the hearing-impaired person for disaster response. The analysis revealed a significant level of unmet needs in disaster response for hearing-impaired person. The 5 special needs in disaster response include: 1) communication needs, which involve securing the means to make an emergency rescue request and communicating information during the rescue process; 2) transportation needs, which indicate the effective evacuation capacity and the level of training; 3) medical needs, which address the degree of preparedness for physical and mental emergency measures and the delivery of health information for rescue and first aid process; 4) maintaining functional independence needs, which refer to the level of self-preparedness to minimize damage in disaster situations, and; 5) supervision needs, which correspond to a personalized support system provided to disaster-vulnerable groups.

A Study on the Crisis Management Standard Manual for Large-scale Human Accident at Workplace for Efficiency of Disaster Response (재난대응 효율화를 위한 사업장 대규모 인적사고 위기관리 표준매뉴얼 개정방안 연구)

  • Woo Sub Shim;Sang Beam Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.656-664
    • /
    • 2023
  • Purpose: The Ministry of Employment and Labor manages disasters based on the standard manual for risk management of large-scale human accidents in workplaces when large-scale disasters such as fires and collapses occur in workplaces. We are going to check the standard manual currently in operation and suggest improvement plans for the insufficient items. Method: Accordingly, the standard manual was checked together with internal and external experts in the disaster management manual and disaster management staff at headquarters and local government offices, and items to be improved were identified with priority. Result: In case of a collapse accident, it is necessary for the Ministry of Public Administration and Security to accurately present the selection criteria in order to eliminate the controversy over the selection of the disaster management department. In addition, it seems necessary to supplement the details of the disaster safety communication network operation and evacuation guidelines. Conclusion: In the future, in order to improve the disaster management system that meets the public's eye level, it is expected to prepare a standard manual for risk management of large-scale human accidents in workplaces that guarantees the lives and safety of workers through the collection of opinions from experts in the relevant field, disaster management personnel, and the general public.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

A Study on Development of Disaster Prevention Automation System on IT using One-chip Type PLC (원칩형 PLC를 이용한 IT 기반 방재용 자동화시스템 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • This paper deals with the quick and precise disaster prevention automation system (DPAS) based on information communication technology (IT) that detects fire and disasters in the building automatically and quickly and then activates the facilities to extinguish fire and disasters, monitoring such situation in a real time through wire-wireless communication network. The proposed DPAS is applied a programmable logic controller (PLC) of one-chip type which is smallsize and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLC analyzes detected signals from sensors in a case of fire and disasters, then activates fire extinguishing facilities for rapid suppression. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication. The transferred data sounds an emergency alarm signal, and operates a monitoring program. The proposed DPAS based on IT will minimize the life and wealth loss from rapid measures while prevents fire and disasters.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

A Study on Automatic Transmission System of Disasters Alarm by Using Wire and Wireless Communication Network - Using by 16bit Microprocessor(Intel 80c196kc) Controller - (유무선통신망을 이용한 재해감지 자동송출시스템에 관한 연구 - 16bit 마이크로프로세서(Intel 80c196kc) 적용 및 응용 -)

  • Kwak, Dong-Kurl;Choi, Shin-Hyeong;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.23-27
    • /
    • 2006
  • With the development of the today's advanced industry civilization, We are always inhering a safety frigidity about disasters of various kinds when and where we may happen. The fires and disasters to be enlarged day by day are reported everyday through the mass communication. Therefore, a prevention countermeasure about the every kind fire and disaster is above all important along the social and the days requirement. As a kind of such countermeasure, this paper is proposed about automatic transmission system of disasters alarm by using wire and wireless communication network. The automatic transmission system prevents the unexpected fire or disaster from a sudden occurrence at the house, industrial field or at the place without the human. The proposed system has the characteristic of high precision and high response speed comparing with conventional system. Also, as the proposed system is small size and lightweight, the users have economic advantage and simply install the system.