• Title/Summary/Keyword: Direct insertion

Search Result 121, Processing Time 0.03 seconds

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.

Cervical Pedicle Screw Insertion Using the Technique with Direct Exposure of the Pedicle by Laminoforaminotomy

  • Jo, Dae-Jean;Seo, Eun-Min;Kim, Ki-Tack;Kim, Sung-Min;Lee, Sang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.459-465
    • /
    • 2012
  • Objective : To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. Methods : We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade of pedicle perforation (grade 0: no perforation, 1: <25%, 2: 20% to 50%, 3: >50% of screw diameter) on the postoperative vascular-enhanced computed tomography scans. Grade 2 and 3 were considered as incorrect position. Results : The correct position was found in 95 screws (91.3%); grade 0-75 screws, grade 1-20 screws and the incorrect position in 9 screws (8.7%); grade 2-6 screws, grade 3-3 screws. There was no neurovascular complication related with cervical pedicle screw insertion. Conclusion : This technique (technique with direct exposure of the pedicle by laminoforaminotomy) could be considered relatively safe and easy method to insert cervical pedicle screw.

Early Phase Contingency Trajectory Design for the Failure of the First Lunar Orbit Insertion Maneuver: Direct Recovery Options

  • Song, Young-Joo;Bae, Jonghee;Kim, Young-Rok;Kim, Bang-Yeop
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.331-342
    • /
    • 2017
  • To ensure the successful launch of the Korea pathfinder lunar orbiter (KPLO) mission, the Korea Aerospace Research Institute (KARI) is now performing extensive trajectory design and analysis studies. From the trajectory design perspective, it is crucial to prepare contingency trajectory options for the failure of the first lunar brake or the failure of the first lunar orbit insertion (LOI) maneuver. As part of the early phase trajectory design and analysis activities, the required time of flight (TOF) and associated delta-V magnitudes for each recovery maneuver (RM) to recover the KPLO mission trajectory are analyzed. There are two typical trajectory recovery options, direct recovery and low energy recovery. The current work is focused on the direct recovery option. Results indicate that a quicker execution of the first RM after the failure of the first LOI plays a significant role in saving the magnitudes of the RMs. Under the conditions of the extremely tight delta-V budget that is currently allocated for the KPLO mission, it is found that the recovery of the KPLO without altering the originally planned mission orbit (a 100 km circular orbit) cannot be achieved via direct recovery options. However, feasible recovery options are suggested within the boundaries of the currently planned delta-V budget. By changing the shape and orientation of the recovered final mission orbit, it is expected that the KPLO mission may partially pursue its scientific mission after successful recovery, though it will be limited.

A Study of Barrier Insertion Loss Near a High Rise Building (고층 건물에 인접한 방음벽의 삽입손실에 관한 연구)

  • 진병주;김현실;김상렬
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2000
  • In this paper performance of the noise barrier which is 53 m long and 6m high, and is located between the high rise apartment and road, is studied by using experimental and analytic method. The insertion loss is measured by using the direct method in accordance with the ISO code, while theoretical prediction is based on Muradali and Fyfe's method (Applied Acoustics, Vol. 53, 49~75, 1998). In addition to the diffraction at the top of the barrier, the waves are reflected infinite times between the building and the barrier, which is equivalent to replacing the building by the infinite series of the image receiver points. In two-dimensional study, the prediction of the insertion loss results in significantly overestimated values compared with the measurement. However three-dimensional analysis shows reasonable agreements, where traffic noise is assumed as incoherent line source and the length of the source is larger than that of the barrier.

  • PDF

Endovascular Treatment of Symptomatic High-Flow Vertebral Arteriovenous Fistula as a Complication after C1 Screw Insertion

  • Jang, Hyun Jun;Oh, Se-Yang;Shim, Yu Shik;Yoon, Seung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.348-352
    • /
    • 2014
  • High-flow vertebral arteriovenous fistulas (VAVF) are rare complications of cervical spine surgery and characterized by iatrogenic direct-communication of the extracranial vertebral artery (VA) to the surrounding venous plexuses. The authors describe two patients with VAVF presenting with ischemic presentation after C1 pedicle screw insertion for a treatment of C2 fracture and nontraumatic atlatoaxial subluxation. The first patient presented with drowsy consciousness with blurred vision. The diffusion MRI showed an acute infarction on bilateral cerebellum and occipital lobes. The second patient presented with pulsatile tinnitus, dysarthria and a subjective weakness and numbness of extremities. In both cases, digital subtraction angiography demonstrated high-flow direct VAVFs adjacent to C1 screws. The VAVF of the second case occurred near the left posterior inferior cerebellar artery originated from the persistent first intersegmental artery of the left VA. Both cases were successfully treated by complete occlusion of the fistulous portion and the involved segment of the left VA using endovascular coil embolization. The authors reviewed the VAVFs after the upper-cervical spine surgery including C1 screw insertion and the feasibility with the attention notes of its endovascular treatment.

Convenient Preparation of Tumor-specific Immunoliposomes Containing Doxorubicin

  • Nam, Sang-Min;Cho, Jang-Eun;Son, Byoung-Soo;Park, Yong-Serk
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.95-100
    • /
    • 1998
  • Two innovative methods to prepare target-sensitive immunoliposomes containing doxorubicin by coupling monoclonal antibodies (mAb DH2, SH1) specific to cancer cell surface antigens ($G_{M3}$, $Le^X$) have been developed and are described here. Firstly, liposomes containing N-glutaryl phosphatidylethanolamine (NGPE) were prepared, followed by the encapsulation of doxorubicin, DH2 or SH1 antibodies were conjugated to NGPE in the liposomes (direct coupling). Secondly, liposomes were prepared with NGPE/mAb conjugates by the detergent dialysis method (conjugate insertion), and then doxorubicin was encapsulated by proton gradient. The immunoliposomes prepared by both methods were able to specifically bind to the surface of the tumor cells - B16BL6 mouse melanoma cells. The efficiencies of doxorubicin-entrapping into liposomes prepared by direct coupling and conjugate insertion was about 98% and 25%, respectively. These types of liposomal formulation are sensitive to target cells, which can be useful for various clinical applications.

  • PDF

Dielectrical and Electrical Characteristics of 9/65/35 PLZT Thin Films (9/65/35 PLZT 박막의 유전적, 전기적 특성)

  • Kang, Chong-Yun;Choi, Hyung-Wook;Paik, Dong-Soo;Yun, Hyun-Sang;Shin, Hyun-Yong;Park, Chang-Yub
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1305-1307
    • /
    • 1994
  • 9/65/35 PLZT thin films were prepared by sol-gel processing and annealed by direct insertion, 9/65/35 PLZT thin films were poly-crystallized after direct insertion at $750^{\circ}C$ for 3omin. The grain size of film was 50 nm, coercive field was 28.2 kV/cm and remnant polarization was $3.68 {\mu}C/cm^2$.

  • PDF

Effect of Dry Process on Dielectric Properties of PZT Thin Films Prepared by Sol-Gel Process

  • Bae, Min-Ho;Lim, Kee-Joe;Kim, Hyun-Hoo;No, Kwang-soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.1
    • /
    • pp.42-45
    • /
    • 2002
  • Properties of lead zirconate titanate ferroelectric thin films prepared by rapid thermal annealing/direct insertion thermal annealing were investigated. The remnant polarization (Pr), saturation polarization (Ps), and coercive force (Ec) of typical samples annealed by rapid thermal annealing (RTA) are about 13.7 $\mu$ C/cm$^2$, 27.1 $\mu$C/cm$^2$, and 55.6 kV/cm, respectively. The dielectric constant of the sample is about 786, the dielectric loss tangent is about 2.4% at 1 kHz. Furthermore, ferroelectric, conduction, and piezoelectric properties of the thin films annealed by RTA process and the direct insertion thermal annealing (DITA) process were compared. The influence of temperature in the dry process on the above properties was also investigated.