• 제목/요약/키워드: Direct Wafer Bonding

검색결과 110건 처리시간 0.02초

전자선 증착된 실리콘 산화막층을 이용한 직접 접합에 관한 연구 (A Study on the Direct Bonding Method using the E-Beam Evaporated Silicon dioxide Film)

  • 박흥우;주병권;이윤희;정성재;이남양;고근하;;박정호;오명환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1988-1990
    • /
    • 1996
  • In this work, we have grown or evaporated thermal oxide and E-beam oxide on the (100) oriented n-type silicon wafers, respectively and they were directly bonded with another silicon wafer after hydrophilization using solutions of three types of $HNO_3$, $H_{2}SO_{4}$ and $NH_{4}OH$. Changes of average surface roughness after hydrophilizations of the single crystalline silicon wafer, thermal oxide and E-beam evaporated silicon oxide were studied using atomic force microscope. Bonding interfaces of the bonded pairs were inspected using scanning electron microscope. Void and non-contact area of the bonded pairs were also inspected using infrared transmission microscope.

  • PDF

열처리 온도에 따른 니켈실리사이드 실리콘 기판쌍의 직접접합 (Direct Bonding of Si(100)/NiSi/Si(100) Wafer Pairs Using Nickel Silicides with Silicidation Temperature)

  • 송오성;안영숙;이영민;양철웅
    • 한국재료학회지
    • /
    • 제11권7호
    • /
    • pp.556-561
    • /
    • 2001
  • 실리사이드반웅을 이용하여 니켈모노실리사이드의 양측계면에 단결정실리콘을 적층시켜 전도성이 우수하며 식각특성이 달라 MEMS용 기판으로 채용이 가능한 SOS (Silicon-on-Silicide) 기판을 제작하였다. 실리콘 기판 전면에 Ni를 열증착법으로$ 1000\AA$두께로 성막하고, 실리콘 기판 경면과 맞블여 후 $300~900^{\circ}C$온도범위에서 15시간동안 실리사이드 처리하여 니켈모노실리사이드가 접합매체로 되는 기판쌍들을 완성하였다. 완성된 기판쌍들은 IR (infrared) 카메라를 이용하여 비파괴적으로 접합상태를 확인하고. 주사전자현미경 (scaning electron microscope)과 투과전자현미경 (tranmission electron microscope)을 이용하여 수직단면 미세구조를 확인하였다. Ni 실리사이드의 상변화가 일어나는 온도를 제외하고는 Si NiSi ∥Si 기판쌍은 기판전면에 52%이상 완전접합이 진행되었음을 확인하였고 생성 실리사이드의 두께에 따라 나타나는 명암부에 비추어 기판쌍 중앙부에 두꺼운 니켈노실리아드가 형성되었다고 판단되었다. 완성된 Si NiSi ∥ Si 기판쌍을 SBM 수직단면에 의괘 확인한 결과 접합이 완성된 기판중심부의 접합계면은 $1000\AA$ 두께의 NiSi가 균일하게 형성되었으며 배율 30,000배의 해상도에서 계면간 분리부분없이 완전한 접합이 진행되었음을 확인하였다. 반면 기판쌍 에지 (edge)부분에는 실리사이드가 헝성되지 않은 비접합상태가 발견되었다. 수직단면루과전자현미경 결과물에 근거하여 접합된 중심부에서는 피접합되는 실리콘의 경면과 니켈이 성막된 실리콘 경면 상부계면에 10-20$\AA$의 비정질막이 발견되었으며, 산화막으로 추정되는 이 막이 접합률을 현저히 저하시키는 것을 확인하였다. 접합이 진행되지 않은 에지부는 이러한 산화막이 열처리 진행중 급격히 성장하여 피접합 실리콘층의 분리가 발생하였다. 따라서 Si NiSi ∥Si 기판쌍의 접합률을 향상시키기 위해서는 피접합 실리콘 계면과 Ni 상부층간의 비정질부를 적극적으로 제거하여야 함을 알 수 있었다.

  • PDF

고온용 실리콘 압력센서 개발 (Development of the high temperature silicon pressure sensor)

  • 김미목;남태철;이영태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.147-150
    • /
    • 2003
  • In this paper, We fabricated a high temperature pressure sensor using SBD(silicon- direct-bonding) wafer of $Si/SiO_2$/Si-sub structure. This sensor was very sensitive because the piezoresistor is fabricated by single crystal silicon of the first layer of SDB wafer. Also, it was possible to operate the sensor at high temperature over $120^{\circ}C$ which is the temperature limitation of general silicon sensor because the piezoresistor was dielectric isolation from silicon substrate using silicon dioxide of the second layer. The sensitivity of this sensor is very high as the measured result of D2200 shows $183.6\;{\mu}V/V{\cdot}kPa$. Also, the output characteristic of linearity was very good. This sensor was available at high temperature as $300^{\circ}C$.

  • PDF

Fabrication of Colloid Thrusters using MEMS Technology

  • Park, Kun Joong;Song, Seung Jin;Sanchez, Manuel Martinez
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.588-592
    • /
    • 2004
  • This paper presents the preliminary fabrication results of colloid thrusters which can provide thrust of the order of micro to milli-Newtons. MEMS technology has been used for fabrication, and four essential fabrication techniques - deep etching with nested masks, isotropic plasma etching, anisotropic reactive ion etching, and direct fusion wafer bonding - have been newly developed. Among diverse models which have been designed and fabricated, the fabrication results of 4-inch wafer-based colloid thrusters are presented.

  • PDF

Micromachinng and Fabrication of Thin Filmes for MEMS-infrarad Detectors

  • Hoang, Geun-Chang;Yom, Snag-Seop;Park, Heung-Woo;Park, Yun-Kwon;Ju, Byeong-Kwon;Oh, Young-Jei;Lee, Jong-Hoon;Moonkyo Chung;Suh, Sang-Hee
    • The Korean Journal of Ceramics
    • /
    • 제7권1호
    • /
    • pp.36-40
    • /
    • 2001
  • In order to fabricate uncooled IR sensors for pyroelectric applications, multilayered thin films of Pt/PbTiO$_3$/Pt/Ti/Si$_3$N$_4$/SiO$_2$/Si and thermally isolating membrane structures of square-shaped/cantilevers-shaped microstructures were prepared. Cavity was also fabricated via direct silicon wafer bonding and etching technique. Metallic Pt layer was deposited by ion beam sputtering while PbTiO$_3$ thin films were prepared by sol-gel technique. Micromachining technology was used to fabricate microstructured-membrane detectors. In order to avoid a difficulty of etching active layers, silicon-nitride membrane structure was fabricated through the direct bonding and etching of the silicon wafer. Although multilayered thin film deposition and device fabrications were processed independently, these could b integrated to make IR micro-sensor devices.

  • PDF

Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발 (Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting)

  • 김성일;김응보;소상균;최지연;정연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

Hydrogen Ion Implantation Mechanism in GaAs-on-insulator Wafer Formation by Ion-cut Process

  • Woo, Hyung-Joo;Choi, Han-Woo;Kim, Joon-Kon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권2호
    • /
    • pp.95-100
    • /
    • 2006
  • The GaAs-on-insulator (GOI) wafer fabrication technique has been developed by using ion-cut process, based on hydrogen ion implantation and wafer direct bonding techniques. The hydrogen ion implantation condition for the ion-cut process in GaAs and the associated implantation mechanism have been investigated in this paper. Depth distribution of hydrogen atoms and the corresponding lattice disorder in (100) GaAs wafers produced by 40 keV hydrogen ion implantation were studied by SIMS and RBS/channeling analysis, respectively. In addition, the formation of platelets in the as-implanted GaAs and their microscopic evolution with annealing in the damaged layer was also studied by cross-sectional TEM analysis. The influence of the ion fluence, the implantation temperature and subsequent annealing on blistering and/or flaking was studied, and the optimum conditions for achieving blistering/splitting only after post-implantation annealing were determined. It was found that the new optimum implant temperature window for the GaAs ion-cut lie in $120{\sim}160^{\circ}C$, which is markedly lower than the previously reported window probably due to the inaccuracy in temperature measurement in most of the other implanters.

Dislocations as native nanostructures - electronic properties

  • Reiche, Manfred;Kittler, Martin;Uebensee, Hartmut;Pippel, Eckhard;Hopfe, Sigrid
    • Advances in nano research
    • /
    • 제2권1호
    • /
    • pp.1-14
    • /
    • 2014
  • Dislocations are basic crystal defects and represent one-dimensional native nanostructures embedded in a perfect crystalline matrix. Their structure is predefined by crystal symmetry. Two-dimensional, self-organized arrays of such nanostructures are realized reproducibly using specific preparation conditions (semiconductor wafer direct bonding). This technique allows separating dislocations up to a few hundred nanometers which enables electrical measurements of only a few, or, in the ideal case, of an individual dislocation. Electrical properties of dislocations in silicon were measured using MOSFETs as test structures. It is shown that an increase of the drain current results for nMOSFETs which is caused by a high concentration of electrons on dislocations in p-type material. The number of electrons on a dislocation is estimated from device simulations. This leads to the conclusion that metallic-like conduction exists along dislocations in this material caused by a one-dimensional carrier confinement. On the other hand, measurements of pMOSFETs prepared in n-type silicon proved the dominant transport of holes along dislocations. The experimentally measured increase of the drain current, however, is here not only caused by an higher hole concentration on these defects but also by an increasing hole mobility along dislocations. All the data proved for the first time the ambipolar behavior of dislocations in silicon. Dislocations in p-type Si form efficient one-dimensional channels for electrons, while dislocations in n-type material cause one-dimensional channels for holes.

SDB와 전기화학적 식각정지에 의한 벌크 마이크로머신용 3차원 미세구조물 제작 (Fabrication of 3-Dimensional Microstructures for Bulk Micromachining by SDB and Electrochemical Etch-Stop)

  • 정귀상;김재민;윤석진
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.958-962
    • /
    • 2002
  • This paper reports on the fabrication of free-standing microstructures by DRIE (deep reactive ion etching). SOI (Si-on-insulator) structures with buried cavities are fabricated by SDB (Si-wafer direct bonding) technology and electrochemical etch-stop. The cavity was formed the upper handling wafer by Si anisotropic etch technique. SDB process was performed to seal the formed cavity under vacuum condition at -760 mmHg. In the SDB process, captured air and moisture inside of the cavities were removed by making channels towards outside. After annealing (100$0^{\circ}C$, 60 min.), the SDB SOI structure with a accurate thickness and a good roughness was thinned by electrochemical etch-stop in TMAH solution. Finally, it was fabricated free-standing microstructures by DRIE. This result indicates that the fabrication technology of free-standing microstructures by combination SDB, electrochemical etch-stop and DRIE provides a powerful and versatile alternative process for high-performance bulk micromachining in MEMS fields.

Design, Fabrication, and Testing of a MEMS Microturbine

  • Jeon Byung Sun;Park Kun Joong;Song Seung Jin;Joo Young Chang;Min Kyoung Doug
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.682-691
    • /
    • 2005
  • This paper describes the design, fabrication, and testing of a microturbine developed at Seoul National University. Here, the term 'microturbine' refers to a radial turbine with a diameter on the order of a centimeter. Such devices can be used to transmit power for various systems. The turbine is designed using a commercial CFD code, and it has a design flow coefficient of 0.238 and work coefficient of 0.542. It has 31 stator blades and 24 rotor blades. A hydrodynamic journal bearing and hydrostatic thrust bearings counteract radial and axial forces on the rotor. The test turbine consists of a stack of five wafers and is fabricated by MEMS technology, using photolithography, DRIE, and bonding processes. The first, second, fourth, and fifth layers contain plumbing, and hydrostatic axial thrust bearings for the turbine. The third wafer contains the turbine's stator, rotor, and hydrodynamic journal bearings. Furthermore, a turbine test facility containing a flow control system and instrumentation has been designed and constructed. In performance tests, a maximum rotation speed of 11,400 rpm and flow rate of 16,000 sccm have been achieved.