• 제목/요약/키워드: Direct Current (DC)

검색결과 435건 처리시간 0.019초

DC 스퍼터링 및 급속 열처리 공정을 이용한 사파이어 기판상에 형성된 2차원 황화몰리브덴 박막의 특성에 관한 연구 (A Study on the Characteristics of 2-Dimensinal Molybdenum Disulfide Thin Films formed on Sapphire Substrates by DC Sputtering and Rapid Thermal Annealing)

  • 척원서;마상민;전용민;권상직;조의식
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.105-109
    • /
    • 2022
  • For the realization of higher reliable transition metal dichalcogenide layer, molybdenum disulfide was formed on sapphire substrate by direct current sputtering and subsequent rapid thermal annealing process. Unlike RF sputtered MoS2 thin films, DC sputtered showed no irregular holes and protrusions after annealing process from scanning electron microscope images. From atomic force microscope results, it was possible to investigate that surface roughness of MoS2 thin films were more dependent on DC sputtering power then annealing temperature. On the other hand, the Raman scattering spectra showed the dependency of significant E12g and A1g peaks on annealing temperatures.

A Novel High-Performance Strategy for A Sensorless AC Motor Drive

  • Lee, Dong-Hee;Kwon, Young-Ahn
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.81-89
    • /
    • 2002
  • The sensorless AC motor drive is a popular topic of study due to the cost and reliability of speed and position sensors. Most sensorless algorithms are based on the mathematical modeling of motors including electrical variables such as phase current and voltage. Therefore, the accuracy of such variables largely affects the performance of the sensorless AC motor drive. However, the output voltage of the SVPWM-VSI, which is widely used in sensorless AC motor drives, has considerable errors. In particular, the SVPWM-VSI is error-prone in the low speed range because the constant DC link voltage causes poor resolution in a low output voltage command and the output voltage is distorted due to dead time and voltage drop. This paper investigates a novel high-performance strategy for overcoming these problems in a sensorless ac motor drive. In this paper, a variation of the DC link voltage and a direct compensation for dead time and voltage drop are proposed. The variable DC link voltage leads to an improved resolution of the inverter output voltage, especially in the motor's low speed range. The direct compensation for dead time and voltage drop directly calculates the duration of the switching voltage vector without the modification of the reference voltage and needs no additional circuits. In addition, the proposed strategy reduces a current ripple, which deteriorates the accuracy of a monitored current and causes torque ripple and additional loss. Simulation and experimentation have been performed to verify the proposed strategy.

가상자속관측기를 이용한 3상 AC/DC PWM PFC 컨버터의 입력전압 센서리스 제어 개선 (Improved Input Voltage Sensorless Control of Three-Phase AC/DC PWM PFC Converter using Virtual Flux Observer)

  • 김영삼;소상호
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.566-574
    • /
    • 2013
  • In this paper, direct power control system for three-phase PFC AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the reduced-order virtual flux observer using the actual currents and the command control voltage. Moreover, source voltage sensors are replaced by a estimated flux. DC output voltage has been compensated by DC output ripple voltage estimation algorithm. The active and reactive powers estimation are performed based on the estimated flux and Phase angle. The proposed algorithm is verified through simulation and experiment.

불평형 전원 조건에서 MMC 기반 HVDC 시스템 순환전류에 관한 연구 (A Study of Circulating Current in MMC based HVDC System under an Unbalanced Grid Condition)

  • 도원석;김시환;김태진;김래영
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1193-1201
    • /
    • 2015
  • This paper presents a study of circulating current of modular multi-level converter (MMC) based a high voltage direct current (HVDC) system under unbalanced grid conditions. Due to the connection of a dependent DC source in each phase, the MMC system inherently generates the power ripple of double-line-frequency components in the AC-side and as a result, the additional sinusoidal current named circulating current flows through the each arm. Reliability improvement of HVDC system under an unbalanced grid condition is one of the important criteria. Generally, the modeling of the circulating current is based on the power relation between DC-side and AC-side. However, the method is not perfectly matched in the MMC system due to the difference of the structural characteristic. In this paper, improved modeling method of circulating current is proposed, which is based on the inner arm power. The proposed method is verified by several simulations to have good agreement of the circulating current components.

직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구 (A Study on the Supply and Stray Current Distribution of the DC Railway Power System)

  • 조웅기;최규형
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.160-168
    • /
    • 2010
  • 본 논문은 직류전기철도 급전시스템에서 누설전류와 변전소로부터 공급되는 전류의 분포에 대하여 다루었다. 일반적으로 직류전기철도 급전시스템에서는 운행용 레일을 귀로 전류(부극성)의 도체로 사용하고 있으며, 이러한 조건은 추가적인 도체의 설치를 필요로 하지 않기 때문에 경제성을 고려한 것이다. 그러나 운행용 레일과 대지 사이의 저항이 작은 경우에는 대지로 흐르는 누설전류가 문제가 된다. 이 누설전류는 레일 주변에 설치된 지하 매설물에 영향을 미치며, 인체의 안전과도 관련이 있다. 따라서 직류전기철도 급전시스템에서 누설전류를 억제하는 것은 차량의 운전이나 안전 측면에서 중요한 문제이다. 본 논문에서는 직류전기철도 급전시스템에 대하여 CDEGS의 SPLIT 프로그램을 이용하여 레일의 전류분포를 시뮬레이션하였고, 레일의 누설저항 크기에 따른 누설전류 변동치를 도출하였다.

교류 구동 방법에 의한 유기전계발광소자 발광 특성의 모델 (Model of Organic Light Emitting Device Emission Characteristics with Alternating Current Driving Method)

  • 서정현;주성후
    • 한국재료학회지
    • /
    • 제31권10호
    • /
    • pp.586-591
    • /
    • 2021
  • This paper proposes a mathematical model that can calculate the luminescence characteristics driven by alternating current (AC) power using the current-voltage-luminance (I-V-L) properties of organic light emitting devices (OLED) driven by direct current power. Fluorescent OLEDs are manufactured to verify the model, and I-V-L characteristics driven by DC and AC are measured. The current efficiency of DC driven OLED can be divided into three sections. Region 1 is a section where the recombination efficiency increases as the carrier reaches the emission layer in proportion to the increase of the DC voltage. Region 2 is a section in which the maximum luminous efficiency is stably maintained. Region 3 is a section where the luminous efficiency decreases due to excess carriers. Therefore, the fitting equation is derived by dividing the current density and luminance of the DC driven OLED into three regions, and the current density and luminance of the AC driven OLED are calculated from the fitting equation. As a result, the measured and calculated values of the AC driving I-V-L characteristics show deviations of 4.7% for current density, 2.9 % for luminance, and 1.9 % for luminous efficiency.

철도차량 견인특성을 고려한 인터리브드 양방향 DC-DC 컨버터의 리플전류 저감에 관한 연구 (A Study on Ripple Current Reduction of Interleaved Bi-directional DC-DC Converter for Traction Characteristic of Railway Vehicle)

  • 이환;정노건;김재문
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.733-739
    • /
    • 2017
  • Research on fuel cell systems attracting attention as an environmentally friendly energy source has been actively conducted. And research is being conducted on railway vehicles that use direct current power generated by a fuel cell as an energy source. In this paper, a two-phase interleaved bidirectional DC-DC converter has been proposed which can supply electric energy of a battery to a traction motor during powering and charge the battery with regenerative energy during braking. Therefore, the topology of the energy storage system applied to the railway vehicle was analyzed, and the simulation was performed by constructing the power conversion system by this topology. Experiments were also conducted through hardware design and fabrication based on the simulation analysis results, and the validity of the hardware implementation was verified.

Finite Control Set Model Predictive Control of AC/DC Matrix Converter for Grid-Connected Battery Energy Storage Application

  • Feng, Bo;Lin, Hua
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1006-1017
    • /
    • 2015
  • This paper presents a finite control set model predictive control (FCS-MPC) strategy for the AC/DC matrix converter used in grid-connected battery energy storage system (BESS). First, to control the grid current properly, the DC current is also included in the cost function because of input and output direct coupling. The DC current reference is generated based on the dynamic relationship of the two currents, so the grid current gains improved transient state performance. Furthermore, the steady state error is reduced by adding a closed-loop. Second, a Luenberger observer is adopted to detect the AC input voltage instead of sensors, so the cost is reduced and the reliability can be enhanced. Third, a switching state pre-selection method that only needs to evaluate half of the active switching states is presented, with the advantages of shorter calculation time, no high dv/dt at the DC terminal, and less switching loss. The robustness under grid voltage distortion and parameter sensibility are discussed as well. Simulation and experimental results confirm the good performance of the proposed scheme for battery charging and discharging control.

PWM 전류형인버터를 이용한 계통연계형 태양광 발전시스템 (Utility Interactive Photovoltaic Generation System using PWM Current Source Inverter)

  • 박춘우;성낙규;이승환;강승욱;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.109-112
    • /
    • 1996
  • In this paper, we composed utility interactive photovoltaic generation system of current source inverter, and controlled that low harmonic and high power factor are hold by supposing control and compensation method which is concerned with synchronous signal distortion and modulation delay. And we put parallel resonant circuit into dc link, so, magnitude of direct reactance was reduce by restraining direct current pulsation which had accumulation of pulsating power in alternating electrolytic condenser. Also we controlled that modulation factor is operated around maximum output of solar cell.

  • PDF

가상 자속관측기를 이용한 3상 AC/DC PFC PWM 컨버터의 직접 전력 센서리스 제어 (Direct Power Sensorless Control of Three-Phase AC/DC PFC PWM Converter using Virtual Flux Observer)

  • 김영삼;권영안
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1442-1447
    • /
    • 2012
  • In this paper, direct power control system for three-phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the Reduced-order flux observer using the actual currents and the command control voltage. The source voltage sensors are replaced by a flux estimator. The active and reactive powers estimation are performed based on the estimated flux and Phase anble. The proposed algorithm is verified through simulation and experiment.