• Title/Summary/Keyword: Diode Detector

Search Result 280, Processing Time 0.033 seconds

Design of a Diode Detector Using Ultra-Wideband Transitions (초광대역 전이 구조를 이용한 다이오드 검파기 설계)

  • Kim, In-Bok;Kim, Young-Gon;Kim, Tae-Gyu;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.814-819
    • /
    • 2008
  • In this paper, a design of broadband detectors utilizing two ultra-wideband transitions is described for the first time, and the implementation method and measurement results of the detectors are provided. Two ultra-wideband transitions are used for input/output matching circuits for the diode detectors. Two detectors have been implemented using general Schottky diodes and zero-bias Schottky diodes. With general Schottky diodes, the fabricated detector provides less than 10 dB return loss from 11 GHz to 20 GHz, and the detector sensitivity is 30 mV/mW. The detector with zero-bias Schottky diodes shows significantly higher detection sensitivity(300 mV/mW).

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF

Design of Power Detection Block for Wireless Communication Transmitter Systems (무선통신 송신시스템용 전력검출부 설계)

  • Hwang, Mun-Su;Koo, Jae-Jin;Ahn, Dal;Lim, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1000-1006
    • /
    • 2007
  • This paper presents a power detector circuit which monitors the transmitting power for the application in CDMA cell phones. The proposed power detector are composed of coupler for coupling output power and detector fur monitoring output power. The designed coupler has low loss characteristic because it adopts the stripline structure which consists of two ground planes at both sides of signal plane. The design frequency is 824-849MHz which is the Tx band fur CDMA mobile terminal, and the coupling factor of the stripline coupler is -20dB. A schottky barrier diode is adopted for detector design because of its high speed operation with minimized loss. The required impedance matching is performed to improve the linearity and sensitivity of output voltage at relatively low detector input level where the nonlinear characteristic of diode exists. The package parasitics as well as intrinsic diode model are considered for simulation of the detector. The predicted performances agree well with the measured results.

  • PDF

New Analytical Method of Cyclosporine A in Human Serum by High -performance Liquid Chromatography/Diode Array Detector and Its Application to Pharmacokinetics of Cyclosporine A in Human Volunteers

  • Kim, Eun-Young;Chung, Yeon-Bok;Kwon, Oh-Seung
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.423.1-423.1
    • /
    • 2002
  • A simple. specific and sensitive method for the determination of cyclosporine A (CsA) in human serum has been developed by a high performance liquid chromatography/diode array detector (DAD) and applied to pharmacokinetic study of CsA. This method involves the use of solid phase extraction procedure following rapid protein precipitation with zinc sulphate from 1 $m\ell$ of human serum, using a disposable $C_{18}$ extraction cartridge. (omitted)

  • PDF

Determination of Levofloaxcin in Human Serum by High-Performance Liquid Chromatography/Diode Array Detector and its Application to Pharmacokinetics of Levofloxacin in Volunteers

  • Kim, Seung-Yong;Chung, Youn-Bok;Kwon, Oh-Seung
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.305.1-305.1
    • /
    • 2003
  • A simple, specific and sensitive method for the determination of levofloaxcin (LFX) in human serum was developed by a high performance liquid chromatography/diode array detector and applied to pharmacokinetic study of LFX in human volunteers. This method involves several steps such as precipitation with acetonitrile, extraction with methylene chloride, evaporation, and concentration, using 0.5ml of the serum. (omitted)

  • PDF

A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control (교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

A Design of the RF Signal Detector for Mobile Communication (이동통신용 RF 신호 검파기 설계)

  • An Jeong-Sig;Kim Kye-Kook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.4 s.32
    • /
    • pp.185-189
    • /
    • 2004
  • In this paper, designed a diode detector and a log chip detector for mobile communication, and its application is proposed by compared results. In practice, fabricated a diode detector have showed detection voltage of $0{\sim}0.7V$ to RF input power of $-40dBm{\sim}-10dBm$, therefore it has suitable characteristic for small variable signal detection. And a log chip detector have showed wide dynamic range of 65dB, and $1.5{\sim}4.5V$ detection voltage to RF input power of $-65dBm{\sim}0dBm$. therefore we have found that it suit peak power measurement because it had insensible output detection voltage.

  • PDF

A Study on the Temperature Compensated and Linearized Power Detector (온도보상 및 선형화 된 전력검출기에 관한 연구)

  • 김희태;오재석;박의준;이영순;김병철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1386-1391
    • /
    • 2000
  • In this paper, the method to linearize the non-linearity of diode and to compensate the characteristics change of diode with the temperature is studied. Square root circuit is used to linearize the non-linearity of diode about the input power, and two identical diodes and OP-Amps, which have variable reference, are used to compensate the characteristic change of diode with the temperature. As the result, designed diode power detector (with the square root circuit and temperature compensation circuit) can detect the output power linearly with the 0.23 $\pm$0.025V/dBm rate in the case the input power is greater than -6 dBm, and the designed circuit operates stably with no variation in the output data about the temperature change from the room temperature to 8$0^{\circ}C$.

  • PDF

Readout Circuit Design for Dual Band IR Detector (중.원 적외선 동시 검출기를 위한 readout 회로 설계)

  • 강상구;김병혁;이희철
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.57-60
    • /
    • 2001
  • A readout circuit for Dual band IR detector was proposed and designed. Designed circuit provide to detector a stable diode bias and high injection efficiency using Buffered Direct Injection (BDI) input circuit. Then, amplifier in the unit cell is operated when cell is selected in order to minimize the power consumption. We could confirm through the simulation that designed circuit integrate and output simultaneously the signal generating from the dual band IR detector.

  • PDF

Small Particle Detection System by Optical Scattering Effect (광 산란특성을 이용한 미세입자 감지시스템)

  • Kim, Eung-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.579-583
    • /
    • 2012
  • We have designed the small particle detection system. The scatteing effect of light was used to detect small particle. The fabricated system consisted of laser diode, lens, pin hole, and photo detector. The aperture, lens, and photo detector were optimized to improve the performance of detection system. The fabricated detection system detected the scattered light by small particle entering into detection system and its response time was fast.