• Title/Summary/Keyword: Dimensional precision

Search Result 1,408, Processing Time 0.029 seconds

A study on the measurement of two-dimensional in-plane displacements of the plate with a circular hole by ESPI method (ESPI에 의한 원공판의 2차원 면내변위 측정에 관한 연구)

  • Kim, Kyoung Suk;Choi, Hyoung Chol;Yang, Seung Pil;Kim, Hyoung Soo;Hong, M.S.;Jung, W.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.161-170
    • /
    • 1994
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interfermetry(ESPI) method, in measuring two-dimensional in- plane displacement. The analysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversial point, measurement error. This error is discussed to be affected not by ESPI method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. Further development of advanced first-order interpolation method is being undertaken for the more precise in-plane strain measurement.

  • PDF

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

Development of Error Compensation Algorithm for Image based Measurement System (미세부품 영상 측정시 진동에 의한 오차 보상 알고리즘 개발)

  • Pyo Chang Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.102-108
    • /
    • 2004
  • In this paper, we studied a vibration problem that is critical and common to most precision measurement systems. For micro mechanical part measurements, results obtained from the vision-based precision measurement system may contain errors due to the vibration. In order to defeat this generic problem, for the current study, a PC based image processing technique was used first, to assess the effect of the vibration to the precision measurement and second, to develop an in-situ calibration algorithm that automatically compensate the measurement results in real time. We used a set of stereoscopic CCD cameras to acquire the images for the dimensional measurement and the reference measurement. The mapping function was obtained through the in-situ calibration to compensate the measurement results and the statistical analysis for the actual results is provided in the paper. Based on the current statistical study, it is expected to obtain high precision results for the micro measurement systems.

Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner (비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교)

  • Park, Jin-Young;Kim, Ji-Hwan;Jeong, Il-Do;Lee, Gwang-Young;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision

  • Kwon, Miran;Cho, Youngmok;Kim, Dong-Wook;Kim, MyungSu;Kim, Yoon-Ji;Chang, Minho
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.95-104
    • /
    • 2021
  • Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 ㎛, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF

NURBS Interpolation Algorithm for CNC Machines (CNC 공작기계의 NURBS 보간 알고리즘에 관한 연구)

  • Hong, Won-Pyo;Yang, Min-Yang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.115-120
    • /
    • 2000
  • Increasing demands on precision machining of free-form surface have necessitated that the tool to move not only position error as small as possible, but also with smoothly varying feedrates. This paper presents new algorithm for high precision 3D(3-dimensional) NURBS(Non-Uniform Rational B-Spline) interpolation in the reference-pulse technique. Based o the minimum path error strategy, interpolation algorithm was designed to follow the NURBS curve. Using this algorithm a real-time 3D NURBS interpolator was developed in software. The algorithm implemented in a PC showed promising results in interpolation error and speed performance. It is expected that this can be applied to the CNC systems for the high precision machining of complex shapes.

  • PDF

A study on detection of composite errors and high precision cutting method by numerical control of two-dimensional circular interpolation in machining centers (Machining center에서 2차원 원호보간의 복합오차 검출 및 수치제어에 의한 고정밀도 가공방법에 관한 연구)

  • Kim, J.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.117-126
    • /
    • 1994
  • This paper describes an application step of a $R^{-{\theta}}$ method which measures circular movements in machining centers. The detection of composite errors of circular movements and a high precision cutting method in machining centers were investigated by the analysis of data measured by $R^{\theta }$method which can detect the rotating angle and is applicable to variable measuring radius. When the error by squareness error and unbalance of position-loop-gain were mixed, the detection method of each error was proposed. Although the errors by squarenss error and backlash compensation were mixed, the errors by squareness error be detected. If the errors by unbalance of position-loop-gain and backlash compensation were mixed, the errors by unbalance of position-loop-gain could not detected. A high precision cutting mehod, which uses the NC program compensated by using feed-back data from error measured by the $R^{\theta }$method, was proposed.

  • PDF

A Study on the Improvement of Positioning accuracy of ultra-precision stage (초정밀스테이지의 위치결정정도 향상에 관한 연구)

  • 황주호;송창규;박천홍;이찬홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.465-468
    • /
    • 2001
  • An aerostatic stage has frictionless behavior, so it has a advantage of investigation into positioning characteristics. A one-dimensional aerostatic ceramic stage with ballscrew driven and laser scale feedback system is manufactured, aiming at investigating positioning characteristic of ultra-precision stage. We confirm, this ceramic aerostatic stage has a 10nm micro resolution, and can be reduced mean of position error by compensation of numeric control command. By means of analyzing relationship of position error and change of temperature, we build a on-line compensation algorithm of position error from the measured temperature data. So we can improve repeatability of ultra-precision stage up to 34%($0.095{\mu}$) of the normal condition.

  • PDF