• Title/Summary/Keyword: Dimensional defects

Search Result 332, Processing Time 0.02 seconds

Influence of Cropped Initial Billet Shape on the Dimensional Tolerance and Tool Life (크로핑 된 초기소재 형상이 금형수명 및 제품의 정밀도에 미치는 영향)

  • Lee D. J.;Kim D. J.;Kim B. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.86-89
    • /
    • 2000
  • In cold forging by multi stage former, crowing process is important process for the high production rate and automation of forging process. But various cropping defects occur in cropping process such as orthogonality, ovality and unevenness, etc. These defects have harmful effects on the dimensional tolerance of products and tool life. So in this study, the cropping experiment is performed to examine influence of cropping process variables(clearance, cutting velocity, H/D) on occurrence of crowing defects and optimum process variables are selected, and then FE analysis is performed to verify influence of these defects on dimensional tolerance and tool life.

  • PDF

Hole Defects on Two-Dimensional Materials Formed by Electron Beam Irradiation: Toward Nanopore Devices

  • Park, Hyo Ju;Ryu, Gyeong Hee;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.107-114
    • /
    • 2015
  • Two-dimensional (2D) materials containing hole defects are a promising substitute for conventional nanopore membranes like silicon nitride. Hole defects on 2D materials, as atomically thin nanopores, have been used in nanopore devices, such as DNA sensor, gas sensor and purifier at lab-scale. For practical applications of 2D materials to nanopore devices, researches on characteristics of hole defects on graphene, hexagonal boron nitride and molybdenum disulfide have been conducted precisely using transmission electron microscope. Here, we summarized formation, features, structural preference and stability of hole defects on 2D materials with atomic-resolution transmission electron microscope images and theoretical calculations, emphasizing the future challenges in controlling the edge structures and stabilization of hole defects. Exploring the properties at the local structure of hole defects through in situ experiments is also the important issue for the fabrication of realistic 2D nanopore devices.

Fabrication of Large Area Photonic Crystals with Periodic Defects by One-Step Holographic Lithography

  • Ma, Jie;Wong, Kam Sing;Li, Shan;Chen, Zhe;Zhou, Jianying;Zhong, Yongchun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.63-68
    • /
    • 2015
  • A one-step fabrication of a photonic crystal (PC) with functional defects is demonstrated. Using multi-beam phase-controlled holographic lithography with a diffracting optical element, large area one dimensional (1D) and two dimensional (2D) PCs with periodic defects were fabricated. The uniform area is up to $2mm^2$, and tens of defect channels have been introduced in the 1D and 2D PC structure. This technique gives rise to substantial reduction in the fabrication complexity and significant improvement in the spatial accuracy of introducing functional defects in photonic crystals. This method can also be used to design and fabricate three dimensional (3D) PCs with periodic defects.

The Detection of Defects in Ferromagnetic Materials Using Magneto-Optical Sensor (자기광학센서를 이용한 강자성체 결함 탐상)

  • Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.52-57
    • /
    • 2004
  • A new non-destructive inspection technique has been developed. One characteristic of the technique is that defects are visualized by laser ray. Magnetic domains and domain walls of a magneto-optical sensor(MO sensor) are varied by the magnetic flux leaked by defects, and the variations are observed by the reflected light of the laser ray. The information of defect can remotely be inspected by this technique in a real time. This paper describes the results estimated on the 2-dimensional surface defects and opposite-side defects in a ferromagnetic material and the natural surface defect in a clutch disk wheel. The light region of a visible image and the magnitude of a reflected light increases as the input current of the magnetizer increases. The natural surface defect, that has not the width of crack's open mouth, can be also visualized like as 2-dimensional artificial defects.

  • PDF

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

An Image Processing Technique for Polarizing Film Defects Detection (편광필름 결함검출을 위한 영상처리기법)

  • Sohn, Sang-Wook;Ryu, Geun-Taek;Bae, Hyeon-Deok
    • 전자공학회논문지 IE
    • /
    • v.45 no.2
    • /
    • pp.20-27
    • /
    • 2008
  • In this paper, we propose a new image processing technique that reliably detects the various defects of TFT-LCD polarizing films. The image of polarizing film is acquisited from reflected laser beam First, we apply the morphological image processing technique to remove the background noise. Next, we use the 2-dimensional LMS adaptive filtering and statistical characteristics to detect the white and black defects. Performance of the proposed method is evaluated on real TFT-LCD polarizing film samples.

A Study on the Detection of Surface Defect Using Image Modeling (영상모델링을 이용한 표면결함검출에 관한 연구)

  • 목종수;사승윤;김광래;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.444-449
    • /
    • 1996
  • The semiconductor, which is precision product, requires many inspection processes. The surface conditions of the semiconductor chip affect on the functions of the semiconductors. The defects of the chip surface are cracks or voids. As general inspection method requires many inspection procedure, the inspection system which searches immediately and precisely the defects of the semiconductor chip surface is required. We suggest the detection algorithm for inspecting the surface defects of the semiconductor surface. The proposed algorithm first regards the semiconductor surface as random texture and point spread function, and secondly presents the character of texture by linear estimation theorem. This paper assumes that the gray level of each pixel of an image is estimated from a weighted sum of gray levels of its neighbor pixels by linear estimation theorem. The weight coefficients are determined so that the mean square error is minimized. The obtained estimation window(two-dimensional estimation window) characterizes the surface texture of semiconductor and is used to discriminate the defects of semiconductor surface.

  • PDF

A Numeric Modelling Technique for the Shape Development of Fatigue Crack (피로 균열 형상 진전의 수치 모델링 기법에 관한 연구)

  • Han, Moon-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.225-233
    • /
    • 1999
  • This paper describes a versatile finite element technique which has been used to investigate of wide range of structural defects of practical importance. The procedure automatically remeshes the three-dimensional finite element model during the stages of crack growth. Problems analyzed to date include the surface cracks in leak-before-break situations, the development of quarter-elliptical corner defects, planar semi-elliptical surface defects and the fatigue growth of defects.

  • PDF

Stress Effects on Activity of Primary Cracks Initiating at Stress Concentrator (응력 집중원에서 발생하는 초기 균열의 거동에 미치는 응력장의 영향)

  • Song, Sam-Hong;Kim, Jin-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.145-153
    • /
    • 1999
  • This study has been performed to investigate the stress distribution around defects that behave as stress concentrators and fracture mechanical analysis for cracks initiatiating at stress concentrators. The stress distribution was analyzed using Finite Element Method and non dimensional stress intensity factor was determined by the mean stress method. In addition, stress interaction effects around defects and cracks were compared.

  • PDF

Reconstruction of the Three-Dimensional Mandibulofacial Defects Using a Single Cutaneous Perforator-Based Fibula Osteocutaneous Flap

  • Kang, In Sook;Ko, Jun Gul;Choi, Ji Seon;Lim, Jin Soo;Kim, Min Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.3
    • /
    • pp.214-217
    • /
    • 2017
  • The reconstruction of the mandibulofacial defects is a difficult task when there are full-thickness cheek defects involving mandible, inner mucosa and outer skin. There are several reconstructive options for the coverage of large defects, but most of the methods are complicated, and time- and effort-consuming. We hereby present a case of fibula osteocutaneous flap based on a single peroneal artery perforator in the reconstruction of a three-dimensional mandibulofacial defects.