• 제목/요약/키워드: Dimensional accuracy

검색결과 2,623건 처리시간 0.032초

엔드밀링의 효과적인 절삭력 모델과 NC 검증시스템으로의 응용 (Fast Force Algorithm of End Milling Processes and Its Application to the NC Verification System)

  • 김찬봉;양민양
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1555-1562
    • /
    • 1995
  • This study represents the non-dimensional cutting force model. With the non-dimensional cutting force model it is possible to estimate efficiently the maximum cutting force during one revolution of cutter. Using the non-dimensional cutting force model, the feed rate and spindle speed are adjusted so as to satisfy the maximum cutting force and maximum machining error. To verify the accuracy and efficiency of the non-dimensional cutting force model, a series of experiments were conducted, and experimental results proved and verified the non-dimensional cutting force model. The NC toolpath verification system developed in this paper uses the non-dimensional cutting force model, so that it is effective for calculating the cutting force and adjusting the cutting conditions.

스프링 힘에 의한 배압부가 단조 공정의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of Forging Processes with Back Pressure Exerted by Spring Force)

  • 장성민;김민철;이민철;전병윤;전만수
    • 소성∙가공
    • /
    • 제19권5호
    • /
    • pp.273-276
    • /
    • 2010
  • In this paper, back pressure forging processes of which back pressures are exerted by mechanical forces including spring reaction are simulated by three-dimensional finite element method. The basic three-dimensional approach extended from two-dimensional approach is accounted for. An axisymmetric backward and forward extrusion process having a back pressing die, which is exposed to oscillation of forming load due to variation of reduction ratios with stroke and its related frequent variation of major deforming region, is simulated by both two and three dimensional approaches to justify the presented approach by their comparison. A three-dimensional forging process having a back pressing die attached to the punch by a mechanical spring is simulated and the results are investigated to reveal accuracy of the presented approach.

The Accuracy of the Non-continuous I Test for One-Dimensional Arrays with References Created by Induction Variables

  • Zhang, Qing
    • Journal of Information Processing Systems
    • /
    • 제10권4호
    • /
    • pp.523-542
    • /
    • 2014
  • One-dimensional arrays with subscripts formed by induction variables in real programs appear quite frequently. For most famous data dependence testing methods, checking if integer-valued solutions exist for one-dimensional arrays with references created by induction variable is very difficult. The I test, which is a refined combination of the GCD and Banerjee tests, is an efficient and precise data dependence testing technique to compute if integer-valued solutions exist for one-dimensional arrays with constant bounds and single increments. In this paper, the non-continuous I test, which is an extension of the I test, is proposed to figure out whether there are integer-valued solutions for one-dimensional arrays with constant bounds and non-sing ularincrements or not. Experiments with the benchmarks that have been cited from Livermore and Vector Loop, reveal that there are definitive results for 67 pairs of one-dimensional arrays that were tested.

Alternative accuracy for multiple ROC analysis

  • Hong, Chong Sun;Wu, Zhi Qiang
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권6호
    • /
    • pp.1521-1530
    • /
    • 2014
  • The ROC analysis is considered for multiple class diagnosis. There exist many criteria to find optimal thresholds and measure the accuracy of diagnostic tests for k dimensional ROC analysis. In this paper, we proposed a diagnostic accuracy measure called the correct classification simple rate, which is defined as the summation of true rates for each classification distribution and expressed as a function of summation of sequential true rates for two consecutive distributions. This measure does not weight accuracy across categories by the category prevalence and is comparable across populations for multiple class diagnosis. It is found that this accuracy measure does not only have a relationship with Kolmogorov - Smirnov statistics, but also can be represented as a linear function of some optimal threshold criteria. With these facts, the suggested measure could be applied to test for comparing multiple distributions.

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.

Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도 (IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM)

  • 김봉철;이채은;박원서;강정완;이충국;이상휘
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권5호
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

스마트폰 카메라의 기하학적 검정과 정확도 평가 (Geometric Calibration and Accuracy Evaluation of Smartphone Camera)

  • 김진수;진청길;이성규;이선구;최철웅
    • 대한공간정보학회지
    • /
    • 제19권3호
    • /
    • pp.115-125
    • /
    • 2011
  • 최근 이슈가 되어온 스마트폰에는 고해상도 카메라, Assisted GPS, 가속도계, 자이로스코프, 그리고 자기 계측 센서와 같이 측량에 직접 이용할 수 있는 다양한 센서들이 탑재되어 있다. 본 연구는 고해상도 영상을 제공하는 스마트폰 카메라를 검정하고 그 정확도를 평가함으로써, 사진측량에 스마트폰 영상의 활용 가능성을 제시하는데 그 목적을 둔다. 먼저, 스마트폰 카메라의 정확도 평가에 앞서 각 카메라의 렌즈 왜곡을 보정하기 위한 카메라 검정이 이루어졌고, 이 과정에서 광속조정에 의해 계산된 영상 좌표 및 대상물 좌표의 정확도를 분석하였다. 또한, 3차원 위치 결정에 있어 렌즈 왜곡 계수의 고려 유무에 따른 결과 분석이 이루어졌고, 최종적으로 측량용 카메라에 대한 스마트폰 카메라의 상대 정확도를 평가하였다. 그 결과, 스마트폰 카메라의 왜곡 보정에 있어 고차항의 방사 왜곡 계수도 고려되어야 하며, 측량용 카메라에 의한 결과와 미소한 차이를 나타내어 사진측량에 스마트폰 영상의 활용 가능성이 클 것으로 기대된다.

다차원 압축성 유동 해석을 위한 MLP 기법의 개발 (Development of Multi-dimensional Limiting Process for Multi-dimensional Compressible Flow)

  • 윤성환;김종암;김규홍
    • 한국항공우주학회지
    • /
    • 제34권7호
    • /
    • pp.1-11
    • /
    • 2006
  • 본 논문에서는 불연속면이 포함된 다차원 유동에서 흔히 발생하는 수치적 진동현상을 막기 위해 기존의 TVD 제한자를 분석함으로써 새로운 형태의 다차원 제한 함수를 유도하였다. MLP 기법은 유도된 다차원 제한 함수를 기반으로 하며, 다차원 불연속면에서의 수치 진동을 효과적으로 제거하고 동시에 3차 이상의 공간 정확도 내삽기법과 함께 사용할 수 있다는 장점을 갖는다. 또한, 정상 유동의 경우 수치 진동이 제거됨으로써 수렴성이 향상됨을 확인할 수 있었고, 실제 코드에 적용하는 방법도 간단하다. MLP 기법을 적용함으로써 불연속 유동 뿐 만 아니라 연속 유동에서도 정확성, 효율성, 강건성 면에서 향상된 결과를 얻을 수 있음을 여러 가지 수치 실험을 통하여 확인하였다.

알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석 (Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions)

  • 주용훈;이진한
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.316-328
    • /
    • 2015
  • 목적: 보관 조건과 석고 주입 시간에 따라 알지네이트 인상체로부터 제작된 모형의 정확성을 알아보고자 하였다. 연구 재료 및 방법: 채득된 알지네이트 인상체는 습도가 유지되는 항습조에 보관하는 것과 진료실 내의 공기 중에 노출되는 상태로 보관 조건을 달리하였다. 보관 조건에 따라 각각 즉시, 채득된 후 10분, 30분, 180분, 360분으로 나누어 보관한 후에 석고 모형을 제작하였다. 제작된 석고 모형을 3D 레이저 스캐너로 삼차원 디지털 모형을 구성하였고 구성된 디지털 모형의 참고점에서 거리를 측정하여 변형률을 비교하였다. 또한 각 실험군의 삼차원 디지털 평균 모형을 제작한 후 중첩을 시행함으로써 표면 변위가 발생한 부위와 크기를 확인하였다. 결과: 인상 채득 즉시 제작한 모형의 변형률이 가장 작게 나타났고, 공기 중에 보관한 인상체보다 항습조에 보관한 인상체의 변형률이 작게 나타났다. 석고 주입 시간이 증가함에 따라서 변형률도 증가하였으며, 석고 주입 시간이 180분을 지나면 보관 조건에 관계없이 대구치 부위에서 변형률과 표면 변위가 증가한다. 결론: 알지네이트 인상체로부터 제작된 모형의 정확성을 위해서는 인상 채득 후, 즉시 모형을 제작해야 한다. 보관이 필요한 경우에는 100% 상대습도가 유지되는 항습조를 이용하고, 보관 시간은 180분을 넘지 않도록 해야 정확한 모형을 얻을 수 있다.

치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향 (Effect of interproximal undercut on the dimensional accuracy of impression)

  • 이주리;김석규
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.330-336
    • /
    • 2015
  • 목적: 본 연구의 목적은 치간 유두의 소실로 인해 치아 사이에 언더컷이 존재하는 경우 이것이 인상체의 정확도에 영향을 미치는지 알아보고자 하는 것이다. 재료 및 방법: 2종류의 부가중합형 실리콘 인상재($Extrude^{(R)}$ Wash, $Imprint^{TM}$ II Quick Step Light Body)와 한 종류의 알지네이트 인상재(Cavex Impressional)로 상악 주모형의 인상을 채득하여 얻은 실험모형상의 두 점 사이의 거리를 측정하여 주모형과 비교하여 모형의 변형 정도를 측정하였다. 세 종류의 인상재에서 얻은 실험 모형들을 치간 유두가 존재하는 군과 존재하지 않는 군으로 나눠 총 6개의 군을 평가하였으며, 각 군당 6개의 모형을 측정하였다. 삼차원 광학 스캐너로 실험모형을 스캔한 후, 하나의 모형당 6개의 두 점 사이의 거리를 삼차원 디지털 계측 소프트웨어 상에서 측정하였다. 측정 거리의 변화 정도를 백분율로 계산하여 모형의 변형률을 구하였으며, 이것을 이원분산분석을 이용하여 유의수준 .05에서 분석하였다. 결과: 측정거리 6개 중 3개에서 인상재에 따라 통계적으로 유의한 차이를 보였다. 반면, 치간 유두의 존재 여부에 따른 차이는 알지네이트 인상재에서 하나의 측정 거리에서만 유의한 차이를 보였을 뿐(P=.047), 다른 측정거리들과 인상재에서는 통계적으로 유의성 있는 차이를 나타내지 않았다. 결론: 치간 유두의 소실로 인한 언더컷의 존재가 부가중합형 실리콘 인상재와 알지네이트 인상재의 체적 정확도에 미치는 영향은 크지 않았다.