• Title/Summary/Keyword: Digital signal

Search Result 4,003, Processing Time 0.028 seconds

Design and Development of VDL Mode-2 D8PSK Modem (VDL Mode-2 D8PSK 모뎀 설계 및 개발)

  • Gim, Jong-Man;Choi, Seoung-Duk;Eun, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11C
    • /
    • pp.1085-1097
    • /
    • 2009
  • We present a structure and design method of the D8PSK modem compatible with the VDL mode-2 standard and performance test results of the developed modem. In VDL mode-2, the raised cosine filter is used only in the transmitter and a general low pass filter is used in the receiver. Consequently, we can not achieve ISI reduction but can have better spectrum characteristics. Although there is 1~2 dB performance degradation with an un-matched filter compared to that with a matched filter, it is more important to minimize adjacent channel interference in narrow band communications. The transmit signal is generated digitally to avoid the problems(I/Q imbalance and DC offset etc.) of analog modulators. In addition the digital down converter using digital IF sampling technique is adopted for the receiver. This paper contains the overall configuration, design method and simulation results based in part on the previously proposed structures and algorithms. It is confirmed that the modem transmits and receives messages successfully at a speed of max. 870 km/h over ranges of up to 310 km through the ground and in-flight communication tests.

A Study on Designing Method of VoIP QoS Management Framework Model under NGN Infrastructure Environment (NGN 기반환경 에서의 VoIP QoS 관리체계 모델 설계)

  • Noh, Si-Choon;Bang, Kee-Chun
    • Journal of Digital Contents Society
    • /
    • v.12 no.1
    • /
    • pp.85-94
    • /
    • 2011
  • QoS(Quality of Service) is defined as "The collective effect of service performance which determines the degree of satisfaction of a user of the service" by ITU-T Rec. E.800. While the use of VoIP(Voice Over Internet Protocol) has been widely implemented, persistent problems with QoS are a very important sue which needs to be solved. This research is finding the assignment of VoIP QoS to deduct how to manage the control system and presenting the QoS control process and framework under NGN(Next Generation Network) environment. The trial framework is the modeling of the QoS measurement metrics, instrument, equipment, method of measurement, the series of cycle & the methodology about analysis of the result of measurement. This research underlines that the vulnerability of the VoIP protocol in relation to its QoS can be guaranteed when the product quality and management are controlled and measured systematically. Especially it's very important time to maintain the research about VoIP QoS measurement and control because the big conversion of new network technology paradigm is now spreading. In addition, when the proposed method is applied, it can reduce an overall delay and can contribute to improved service quality, in relation to signal, voice processing, filtering more effectively.

On the speaker's position estimation using TDOA algorithm in vehicle environments (자동차 환경에서 TDOA를 이용한 화자위치추정 방법)

  • Lee, Sang-Hun;Choi, Hong-Sub
    • Journal of Digital Contents Society
    • /
    • v.17 no.2
    • /
    • pp.71-79
    • /
    • 2016
  • This study is intended to compare the performances of sound source localization methods used for stable automobile control by improving voice recognition rate in automobile environment and suggest how to improve their performances. Generally, sound source location estimation methods employ the TDOA algorithm, and there are two ways for it; one is to use a cross correlation function in the time domain, and the other is GCC-PHAT calculated in the frequency domain. Among these ways, GCC-PHAT is known to have stronger characteristics against echo and noise than the cross correlation function. This study compared the performances of the two methods above in automobile environment full of echo and vibration noise and suggested the use of a median filter additionally. We found that median filter helps both estimation methods have good performances and variance values to be decreased. According to the experimental results, there is almost no difference in the two methods' performances in the experiment using voice; however, using the signal of a song, GCC-PHAT is 10% more excellent than the cross correlation function in terms of the recognition rate. Also, when the median filter was added, the cross correlation function's recognition rate could be improved up to 11%. And in regarding to variance values, both methods showed stable performances.

Video Replay by Frame Receive Order Relocation Method in the Wire and Wireless Network (유무선 네트워크에서 프레임 수신 순서 재할당 방법을 사용한 동영상 재생)

  • Kang, Dong-Jin;Kim, Dong-Hoi
    • Journal of Digital Contents Society
    • /
    • v.17 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • When video service is performed in simulation using NS-2(Network Simulation-2), the video replay is performed as the received frame order. In the existing video replay method based on the received frame order, as the frame orders of receiver and transmitter are different, the receiver buffer does not have the effect that the packets between the frames of transmitter buffer holds a regular size and packet dense and sparsity phenomenon in the receiver buffer is made by the irregular packet size due to the unpredictable reversed order of received partial frames. The above dense and sparsity phenomenon increases the probability of buffer overflow and underflow generation. To prevent these problems, the proposed frame receive order relocation method adds an extra replay buffer which rearranges the order of receive frame as the order of transmit frame, so it has the effect that the packets between the transmit frames keeps a regular size. Through the simulation using NS-2 and JSVM(Joint Scalable Video Model), the generation number of buffer overflow and underflow, and PSNR(Required Peak Signal to Noise Ratio) performance between the existing method and proposed method were compared. As a result, it was found that the proposed method would have better performance than the existing method.

A GaAs MMIC Multi-Function Chip with a Digital Serial-to-Parallel Converter for an X-band Active Phased Array Radar System (X-대역 능동 위상 배열 레이더 시스템용 디지털 직병렬 변환기를 포함한 GaAs MMIC 다기능 칩)

  • Jeong, Jin-Cheol;Shin, Dong-Hwan;Ju, In-Kwon;Yom, In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.613-624
    • /
    • 2011
  • An MMIC multi-function chip for an X-band active phased array radar system has been designed and fabricated using a 0.5 ${\mu}m$ GaAs p-HEMT commercial process. A digital serial-to-parallel converter is included in this chip in order to reduce the number of the control interface. The multi-function chip provides several functions: 6-bit phase shifting, 6-bit attenuation, transmit/receive switching, and signal amplification. The fabricated multi-function chip with a relative compact size of 24 $mm^2$(6 mm${\times}$4 mm) exhibits a transmit/receive gain of 24/15 dB and a P1dB of 21 dBm from 8.5 GHz to 10.5 GHz. The RMS errors for the 64 states of the 6-bit phase shift and attenuation were measured to $7^{\circ}$ and 0.3 dB, respectively over the frequency.

Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development (X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발)

  • Lee, Kwang-In;Jang, Jin-Soo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.331-339
    • /
    • 2016
  • Chronic diseases are increasing nowadays as daily habits changed due to economic growth. Among chronic diseases, heart cerebrovascular disease is one of the major causes of death in South Korea that accounts for approximately 20% of mortality. Tests to measure anomaly of the heart is ECG tests, which measures and analyzes the electrical heart activity. Any mistakes in lead attachment location critically affects ECG testings, and statistical facts showed that only 2.8% of the nurses properly located leads to patients. As a solution, this paper proposes a system based on a projection-based augmented reality technology to generate X-ray images to the patient's chest to point out exact attachment locations of ECG leads. Evaluation comparison results showed a 2.6 cm difference between the conventional system and the proposed system. ECG test results also showed significant signal differences between the systems in leads V1, V2, and V3. The ECG measured accurately by the proposed system would help greatly in patient management and clinical decisions of clinicians.

Gender Analysis in Elderly Speech Signal Processing (노인음성신호처리에서의 젠더 분석)

  • Lee, JiYeoun
    • Journal of Digital Convergence
    • /
    • v.16 no.10
    • /
    • pp.351-356
    • /
    • 2018
  • Changes in vocal cords due to aging can change the frequency of speech, and the speech signals of the elderly can be automatically distinguished from normal speech signals through various analyzes. The purpose of this study is to provide a tool that can be easily accessed by the elderly and disabled people who can be excluded from the rapidly changing technological society and to improve the voice recognition performance. In the study, the gender of the subjects was reported as sex analysis, and the number of female and male voice samples was used equally. In addition, the gender analysis was applied to set the voices of the elderly without using voices of all ages. Finally, we applied a review methodology of standards and reference models to reduce gender difference. 10 Korean women and 10 men aged 70 to 80 years old are used in this study. Comparing the F0 value extracted directly with the waveform and the F0 extracted with TF32 and the Wavesufer speech analysis program, Wavesufer analyzed the F0 of the elderly voice better than TF32. However, there is a need for a voice analysis program for elderly people. In conclusions, analyzing the voice of the elderly will improve speech recognition and synthesis capabilities of existing smart medical systems.

Analysis Method for Full-length LiDAR Waveforms (라이다 파장 분석 방법론에 대한 연구)

  • Jung, Myung-Hee;Yun, Eui-Jung;Kim, Cheon-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.4 s.316
    • /
    • pp.28-35
    • /
    • 2007
  • Airbone laser altimeters have been utilized for 3D topographic mapping of the earth, moon, and planets with high resolution and accuracy, which is a rapidly growing remote sensing technique that measures the round-trip time emitted laser pulse to determine the topography. The traveling time from the laser scanner to the Earth's surface and back is directly related to the distance of the sensor to the ground. When there are several objects within the travel path of the laser pulse, the reflected laser pluses are distorted by surface variation within the footprint, generating multiple echoes because each target transforms the emitted pulse. The shapes of the received waveforms also contain important information about surface roughness, slope and reflectivity. Waveform processing algorithms parameterize and model the return signal resulting from the interaction of the transmitted laser pulse with the surface. Each of the multiple targets within the footprint can be identified. Assuming each response is gaussian, returns are modeled as a mixture gaussian distribution. Then, the parameters of the model are estimated by LMS Method or EM algorithm However, each response actually shows the skewness in the right side with the slowly decaying tail. For the application to require more accurate analysis, the tail information is to be quantified by an approach to decompose the tail. One method to handle with this problem is proposed in this study.

Image Generator Design for OLED Panel Test (OLED 패널 테스트를 위한 영상 발생기 설계)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.25-32
    • /
    • 2020
  • In this paper, we propose an image generator for OLED panel test that can compensate for color coordinates and luminance by using panel defect inspection and optical measurement while displaying images on OLED panel. The proposed image generator consists of two processes: the image generation process and the process of compensating color coordinates and luminance using optical measurement. In the image generating process, the panel is set to receive the panel information to drive the panel, and the image is output by adjusting the output setting of the image generator according to the panel information. The output form of the image is configured by digital RGB method. The pattern generation algorithm inside the image generator outputs color and gray image data by transmitting color data to a 24-bit data line based on a synchronization signal according to the resolution of the panel. The process of compensating color coordinates and luminance using optical measurement outputs an image to an OLED panel in an image generator, and compensates for a portion where color coordinates and luminance data measured by an optical module differ from reference data. To evaluate the accuracy of the image generator for the OLED panel test proposed in this paper, Xilinx's Spartan 6 series XC6SLX25-FG484 FPGA was used and the design tool was ISE 14.5. The output of the image generation process was confirmed that the target setting value and the simulation result value for the digital RGB output using the oscilloscope matched. Compensating the color coordinates and luminance using optical measurements showed accuracy within the error rate suggested by the panel manufacturer.

A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb (하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.431-437
    • /
    • 2015
  • This convergence study analyzed the effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb. 48 patients of 125 cc contrast agent and 30 patients of the same amount divided at a ratio of 7:3 for the contrast agent and normal saline solution were studied. The average attenuation coefficient(HU) and signal to noise ratio(SNR) of abdominal aorta, femoral artery, popliteal artery and posterior tibial artery at each image were evaluated quantitatively and the four criteria in the five point scale was conducted qualitatively by two radiologists and four radiological technologists. In the quantitative evaluation, both HU and SNR had high average score before dilation but there were no statistical significance by independent t-test(p>0.05). In the qualitative evaluation, there were a little differences in the average scores between 4.86~4.77 of original contrast agent and 4.83~4.67 of dilated contrast agent but there were no statistical significance(p>0.05). In the computed tomography of arteries of lower limb, the dilated contrast agent doesn't influence image quality and reduces overall contrast agent and lowers iodine content per unit of molecular therefore will contribute to decrease side effect of contrast agent.