디지털 신호처리기를 이용한 전력계통 주파수 측정에 관한 연구 (A study on the Measurement of Power system Frequency using Digital Signal Processor)

  • 이정우;오용택
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.113-119
    • /
    • 2011
  • A frequency in electrical power system changes by the load fluctuation in utility grid, has an influence on a connected generator, and ultimately brings a big trouble in the power system. Therefore, a quick measurement of system frequency and governor control of power system is a very important factor in the reliability and the economic feasibility. Electromagnetic frequency relays in the past had the large power consumption and the difficulty of accurate measurement. After Researched and developed digital relays are very affected by the noise and the distortion, and the recently developed Microprocessor relays have problems of expensive device and time when measuring the frequency at 50[ms]. In this study, An improve algorithm that measures the power system frequency quickly and accurately is suggested, simulated by using Matlab and programmed using C code through DSP6713 KIT. This algorithm is tested to the arbitrary voltage waveform input. The results show that the suggested algorithm is effective in the accurate and quick frequency measurements.

전력설비를 위한 디지털보호계전기의 FPGA 구현 (A FPGA Implementation of Digital Protective Relays for Electrical Power Installation)

  • 김종태;신명철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.131-137
    • /
    • 2005
  • 보호계전기는 고장에 의해 파생되는 단락$\cdot$지락 사고로부터 전력 시스템을 보호하기 위하여 널리 사용되고 있다. 전통적으로 디지털보호계전기는 디지털신호처리 프로세서 혹은 마이크로프로세서로 구현되는데 본 연구는 이를 고성능$\cdot$고효율$\cdot$다기능의 단일칩으로 구현하기 위한 하드웨어 설계 기술에 관해 다룬다. 제작된 디지털보호계전기는 FPGA(Field Programmable Gate Array)로 구현하였고 16KSPS이상의 처리 성능을 가지며 평균 오차율 $0.03(\%)$미만으로 보호계전알고리즘을 수행할 수 있다.

철심 변류기의 2차 전류 보상 알고리즘의 실시간 구현 및 오차 분석 (Hardware implementation and error analysis of an algorithm for compensating the secondary current of iron-cored current transformers)

  • 강용철;김성수;박종근;강상희;김광호
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.490-500
    • /
    • 1996
  • The conventional method to deal with current transformer (CT) Saturation is over dimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10% ratio correction. However, this not only reduces the sensitivity of relays as some errors may still be present in the secondary current when a severe fault occurs, but also increases the CT size. This paper presents an algorithm for compensating the distorted secondary current of iron-cored CTs under CT saturation using the magnetization (flux-current : .lambda.-i) curve and its performance is examined for fault currents encountered on a typical 345[kV] Korean transmission system, under a variety of different system and fault conditions. In addition, the results of hardware implementation of the algorithm using a TMS320C10 digital signal processor are also presented. The proposed algorithm can improve the sensitivity of relays to low level internal faults, maximize the stability of relays for external faults, and reduce the required CT core cross-section significantly. (author). refs., figs.

  • PDF

디지털 역결상 보호 계전기의 설계 및 제작 (Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase)

  • 김우현;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

PSCAD/EMTDC를 이용한 거리계전기 동특성 시험에 관한 컴포넌트 모델 개발 (Development of User-defined Components for Dynamic Test of Distance Relay Models Using PSCAD/EMTDC)

  • 이홍학;이태영;김호표;노장현;강근수;장성훈;이재욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.242-244
    • /
    • 2003
  • The functional test of protection relays is divided into two kind of test types; the steady-state test and dynamic test. Because the steady-state test is comparatively easy, this test is used to test the characteristics of the relaying elements, operating values, resetting values and etc. using equipment such as Doble. But the dynamic test has to be performed on the test environment with RTDS(real time digital simulator) because of the dynamic characteristics of real protection relays. Therefore, it is not usually easy to perform dynamic test of relays using power system simulation tool based on PC(personal computer) such as PSCAD/EMTDC. This paper discusses how to develop and implement a test model and user-defined components that can be performed dynamic test using PSCAD/EMTDC.

  • PDF

DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘 (Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method)

  • 이동규;강상희
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.

Adaptive Protection Algorithm for Overcurrent Relay in Distribution System with DG

  • Sung, Byung Chul;Lee, Soo Hyoung;Park, Jung-Wook;Meliopoulos, A.P.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1002-1011
    • /
    • 2013
  • This paper proposes the new adaptive protection algorithm for inverse-time overcurrent relays (OCRs) to ensure their proper operating time and protective coordination. The application of the proposed algorithm requires digital protection relays with microcontroller and memory. The operating parameters of digital OCRs are adjusted based on the available data whenever system conditions (system with distributed generation (DG)) vary. Moreover, it can reduce the calculation time required to determine the operating parameters for achieving its purpose. To verify its effectiveness, several case studies are performed in time-domain simulation. The results show that the proposed adaptive protection algorithm can keep the proper operating time and provide the protective coordination time interval with fast response.

보호계전기 특성시험기술의 시험항목 변화 (Testing Items Change on Characteristics of Protective relays)

  • 장병태;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.161-162
    • /
    • 2008
  • The steady state performance test for the digital protective relay using general relay test equipment has been main test methods. Because of the development of advanced power system testing equipments, dynamic performance test has been carried out additionally using a digital simulator such as RTDS(Real Time Digital Simulator). For the case of newly adopted digital protective relay with IEC 61850 and network, performance testing items need supplementing. This report displays testing items change according to newly protective relay.

  • PDF

네트워크 코딩 및 디지털 파운 테인 코드를 사용하여 간단한 양방향 전송 프로토콜 (Simple Bidirectional Transmission Protocols Cooperative Transmission using Network Coding and Digital Fountain Codes)

  • 공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.23-28
    • /
    • 2013
  • 본 논문에서는 네트워크 코딩 및 파운 테인 코드를 사용한 간단한 양방향 전송 프로토콜을 제안한다. 특히, 제안된 기법의 경우, 두 소스는 중계기의 도움으로 서로에게 메시지를 전송하기위해 디지털 파운틴 코드를 사용한다. 또한, 중계기는 파운틴 코드와 네트워크 코딩을 사용하여 수신 받은 소스의 메시지를 서로의 소스에게 전송한다. 제안된 프로토콜의 성능을 평가하기위해 레일리 페이딩 채널에서 다양한 몬테-카를로 시뮬레이션을 통하여 전체 평균 처리량을 확인한다. 그 결과 제안된 프로토콜은 높은 SNR 영역에서 네트워크 코딩 기술을 사용하지 않는 두 방향 릴레이 전송 프로토콜보다 우수함을 확인하였다.

OFDM 시스템을 위한 순환 지연을 사용하는 협력 다이버시티 기법 (Cooperative Diversity using Cyclic Delay for OFDM systems)

  • 이동우;정영석;이재홍
    • 방송공학회논문지
    • /
    • 제13권2호
    • /
    • pp.172-178
    • /
    • 2008
  • 고속데이터무선통신시스템을 위한 핵심기술로 각광받고 있는 OFDM은 디지털 오디오 방송(DAB)과 디지털 지상 텔레비전 방송(DVB-T)의 표준 기술로 채택되었다. 최근 활발하게 연구되고 있는 협력 다이버시티 기술을 OFDM에 적용할 경우, 다이버시티 이득과 시스템 용량을 극대화시켜서 차세대 무선통신이 요구하는 높은 데이터 전송률과 신뢰도를 달성할 수 있을 것으로 기대된다. 본 논문에서는 OFDM 시스템을 위한 순환 지연을 사용하는 협력 다이버시티 기법을 제안한다. 제안된 기법에서는 다중 중계 단말기를 사용하여 단일 중계단말기를 위한 협력 다이버시티 기법에 비해 비약적인 성능 향상을 제공하고, 다중 중계단말기의 협력에 따른 이득을 극대화시키기 위하여 순환 지연을 적용한다. 모의실험을 통해 제안된 기법이 기존 시스템에 비해 우수한 성능을 제공함을 보인다.