• 제목/요약/키워드: Digital position

검색결과 1,366건 처리시간 0.025초

디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과 (Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position)

  • 김미자;최보람;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

디지털 PI 제어에 의한 HLPM의 안정된 위치제어 (The Stable Position Control of Hybrid type Linear Pulse Motor by Digital PI Control)

  • 윤신용;백수현;김용;김철진;맹인재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권10호
    • /
    • pp.637-645
    • /
    • 2000
  • This study was represented the improvement of the flexible position control for linear motion of hybrid type linear pulse motor(HLPM). The driving method used a minute 125 microstep drive instead of full step drive method. The digital control method was applied to the PI control for more stable position control, at this time the PI control parameters have gained by a Ziegler-Nichols turning method. The loop transfer function of control system was combined with both motor transfer function and digital PI control equation. Such, the proper for digital PI control system is verified to through the simulation and experimental result of the stability step response and bode plot with proper gain and phase margin.

  • PDF

최대우도함수를 이용한 양전자방출단층촬영기기의 검출기 모듈의 디지털 위치 획득 방법 (Digital Position Acquisition Method of PET Detector Module using Maximum Likelihood Position Estimation)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2021
  • 양전자방출단층촬영기기에서 영상을 획득하기 위해서는 동시 측정된 검출기 모듈의 섬광 픽셀의 위치 좌표를 서로 연결하는 과정이 필요하다. 이를 위해서 다수의 섬광 픽셀과 소수의 광센서를 사용하는 검출기 모듈에서는 평면 영상을 획득하여 각 섬광 픽셀의 영역을 나누어 감마선과 상호작용한 섬광 픽셀의 위치를 획득해야 한다. 또는 사용하는 섬광 픽셀의 수와 광센서의 수를 동일하게 구성할 경우는 섬광 픽셀 위치에 대한 위치 좌표를 직접 디지털 신호 좌표로 획득할 수 있다. 다수의 섬광 픽셀과 소수의 광센서를 사용하는 방법은 평면 영상 획득과 영역을 나누는 과정이 필요하며, 디지털 신호 좌표를 직접 획득하는 방법은 다수의 광센서와 신호처리 시스템이 필요하다. 이는 신호처리 과정이 복잡해지며, 비용이 상승하는 문제가 발생한다. 이를 해결하기 위해 본 연구에서는 다수의 섬광 픽셀과 소수의 광센서를 사용하여 평면 영상 및 영역의 분리과정을 수행하지 않고 디지털 신호 좌표를 획득하는 방법을 개발하였다. 최대우도함수를 사용하여 각 섬광 픽셀에서 획득한 신호를 통해 작성된 순람표를 통해 감마선과 상호작용한 섬광 픽셀의 위치 좌표값을 디지털 신호로 획득하는 방법이다. DETECT2000을 사용하여 시뮬레이션을 실시하였으며, 제시한 방법에 대해 검증을 실시하였다. 그 결과 모든 섬광 픽셀에서 정확한 디지털 신호 좌표를 획득할 수 있었으며, 이를 기존 시스템에 적용할 경우 신호처리 과정의 단순화로 보다 빠른 영상획득이 가능할 것으로 판단된다.

지도 정보를 활용한 저사양 GPS의 위치 정확도 향상 기법 (Low-end GPS Position Accuracy Enhancement Method by using Map Information)

  • 최덕선;강정민;김한솔;박진배
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.659-665
    • /
    • 2016
  • In this paper, we propose a novel position accuracy enhancement method of a low-end GPS using digital map information. The latest digital map has various kinds of information on geographical features. The proposed method uses position information of lane marks among the geographical features. We define the position information of lane marks as the reference points. The position information of a low-end GPS acquired for a period of time is defined as the source points. In the proposed method, rotation and translation matrices between the reference and the source points are calculated by using an Iterative Closest Point(ICP) algorithm. The source points are transformed by the obtained rotation and translation matrices. Finally, the transformed source points are projected on the reference points. Through these processes, the position accuracy of a low-end GPS is ultimately enhanced. To verify the proposed method, the various real experimental results are presented.

임상가를 위한 특집 1 - Digital Orthodontics를 이용한 진단과 치료 현황 (Clinical Applications of CBCT and 3D Digital Technology in Orthodontics)

  • 박재현
    • 대한치과의사협회지
    • /
    • 제52권1호
    • /
    • pp.8-16
    • /
    • 2014
  • The introduction of cone-beam computed tomography(CBCT) and computer software in orthodontics has allowed orthodontists to provide more accurate diagnosis and treatment. The most common use of CBCT imaging allows orthodontists to visualize the precise position of supernumerary or impacted teeth, especially impacted canines. In doing so, the exact angulation of impaction and proximity of adjacent roots can be evaluated by orthodontists, allowing them to choose vector forces for tooth movement while minimizing root resorption. Even though 2-dimensional panoramic images can be used to view the position of the impacted canines, they have limitations because it is not possible to evaluate the impacted tooth position 3-dimensionally. An accurate knowledge of root position improves the determination of success in orthodontic treatment. Nowadays, considering the fast pace of technological development, a combination of intraoral scanning, digital setups, custommade brackets and wires, and indirect bonding may soon become the orthodontic standard. In this paper, this will be discussed along with the digital models.

적은 수의 광센서를 사용한 PET 검출기의 최대우도함수를 적용한 디지털 위치 측정 (Digital Position Measurement with MLPE of PET detector using a Small Number of Photosensors)

  • 강승훈;이승재
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-156
    • /
    • 2022
  • 적은 수의 광센서를 사용하는 검출기를 설계하고, 최대우도함수를 통해 감마선과 상호작용한 섬광 픽셀의 위치를 디지털 위치로 측정하는 연구를 수행하였다. 이를 위해 섬광체 내에서 빛의 이동을 모사할 수 있는 DETECT2000을 사용하여 시뮬레이션을 수행하였으며, 위치 측정의 정확도를 평가하였다. 6 × 6의 섬광 픽셀 배열과 4개의 광센서를 사용하여 검출기를 구성하였으며, 각 섬광 픽셀 중심에서 감마선 이벤트를 발생시켜 수집된 빛의 비율을 통해 순람표를 작성하였다. 새로운 위치에서 발생된 감마선 이벤트를 최대우도함수의 입력값으로 적용하여 순람표와 비교후 섬광 픽셀의 위치를 디지털 위치로 변환하였다. 모든 섬광 픽셀들에서 평가하였으며, 그 결과 99.1%의 높은 정확도를 획득하였다. 이러한 방법을 현재 사용되는 시스템에 적용할 경우 섬광 픽셀의 위치를 판별하는 과정의 간소화를 이룰 것으로 판단된다.

위상차 방식을 사용한 용량방식 터치 스크린 패널의 접촉 위치 검출 (Pointing position detection of capacitive touch screen panel using phase-difference method)

  • 조영철;장래혁;권욱현
    • 제어로봇시스템학회논문지
    • /
    • 제4권3호
    • /
    • pp.406-412
    • /
    • 1998
  • This paper describes a contact position detection method of a capacitive touch screen panel. The proposed method is composed of a circuited compensating algorithm generating an output signal having phase difference to an input signal associated with contact position, converts both input and output signals into digital waveform (5V logic), and calculates the phase difference. Finally, position information with the phase difference is obtained by using a low-cost microprocessor, which is convenient to compensate non-linearity error. The proposed method, that computes phase difference directly, has advantages in feasibility and cost because it minimizes the use of analog devices; rather, it utilizes, cost effective digital circuit. Analytical results are also given.

  • PDF

LiDAR 데이터를 이용한 지형지물의 위치정확도 분석 (Analysis of Position Accuracy of Topography using LiDAR Data)

  • 김용석;김성철
    • 한국콘텐츠학회논문지
    • /
    • 제8권3호
    • /
    • pp.270-278
    • /
    • 2008
  • 본 연구에서는 연구지역을 대상으로 LiDAR(Light Detection And Ranging) 데이터와 항공사진, 수치 지도를 이용하여 지형지물에 대한 위치정확도 분석을 실시하였다. 연구지역은 부산광역시 사하구 하단지역으로 선정하였으며, 첨단 측량기법인 항공 LiDAR 데이터와 축척 1:20,000의 항공사진을 이용하였다. 그리고 각각의 영상에 대하여 표정작업과 영상의 재배열 과정을 거쳐 최종 수치정사영상을 제작하였다. 제작된 영상을 이용하여 검사점을 선정하고, 선정된 검사점에 대한 정보를 추출하였으며, 스크린 디지타이징기법을 통한 수평위치 좌표를 추출하였다. 그리고 국토지리 정보원에서 공시한 축척 1:5,000의 수치지도를 이용하여 추출된 LiDAR 데이터 좌표와 항공사진의 좌표를 각각 비교.분석하였다. 수치지도를 기준으로 비교 분석한 결과 항공사진의 수평위치 정확도가 항공 LiDAR 측량 성과 보다 건물의 경우 x방향으로 24cm, y방향으로 26cm정도가 우수함을 알 수 있었다.

디지털 히스테리시스 제어기를 이용한 SRM의 위치제어시스템 (A Position Control System of SRM using Digital Hysteresis Controller)

  • 백원식;김남훈;최경호;김동희;김민회;황돈하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an implementation of motion control system of Switched Reluctance Motor (SRM) using digital hysteresis controller by TMS320F240 DSP. SRM position control system possess several advantages over other motors, including high efficiency, simple structure, low cost, and four-quadrant operation at a wide speed range, especially for the servo drive systems with precision, stability and fast response characteristics in the industrial applications. In the suggested motion control system, position control using digital hysteresis controller is developed, and is evaluated using experimental testing. The developed system for cost reduction and high-performance by fully digital controller is shown a good response characteristic of motion control results.

  • PDF

PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구 (A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy)

  • 최훈일;조용준;유영기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF