• 제목/요약/키워드: Digital optical imaging

검색결과 119건 처리시간 0.03초

Optical Encryption and Information Authentication of 3D Objects Considering Wireless Channel Characteristics

  • Lee, In-Ho;Cho, Myungjin
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.494-499
    • /
    • 2013
  • In this paper, we present an optical encryption and information authentication of 3D objects considering wireless channel characteristics. Using the optical encryption such as double random phase encryption (DRPE) and 3D integral imaging, a 3D scene with encryption can be transmitted. However, the wireless channel causes the noise and fading effects of the 3D transmitted encryption data. When the 3D encrypted data is transmitted via wireless channel, the information may be lost or distorted because there are a lot of factors such as channel noise, propagation fading, and so on. Thus, using digital modulation and maximum likelihood (ML) detection, the noise and fading effects are mitigated, and the encrypted data is estimated well at the receiver. In addition, using computational volumetric reconstruction of integral imaging and advanced correlation filters, the noise effects may be remedied and 3D information may be authenticated. To prove our method, we carry out an optical experiment for sensing 3D information and simulation for optical encryption with DRPE and authentication with a nonlinear correlation filter. To the best of our knowledge, this is the first report on optical encryption and information authentication of 3D objects considering the wireless channel characteristics.

Two-step Holographic Imaging Method based on Single-pixel Compressive Imaging

  • Li, Jun;Li, Yaqing;Wang, Yuping;Li, Ke;Li, Rong;Li, Jiaosheng;Pan, Yangyang
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.146-150
    • /
    • 2014
  • We propose an experimental holographic imaging scheme combining compressive sensing (CS) theory with digital holography in phase-shifting conditions. We use the Mach-Zehnder interferometer for hologram formation, and apply the compressive sensing (CS) approach to the holography acquisition process. Through projecting the hologram pattern into a digital micro-mirror device (DMD), finally we will acquire the compressive sensing measurements using a photodiode. After receiving the data of two holograms via conventional communication channel, we reconstruct the original object using certain signal recovery algorithms of CS theory and hologram reconstruction techniques, which demonstrated the feasibility of the proposed method.

DESIGN CONCEPT FOR SINGLE CHIP MOSAIC CCD CONTROLLER

  • HAN WONYONG;JIN Ho;WALKER DAVID D.;CLAYTON MARTIN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.389-390
    • /
    • 1996
  • The CCDs are widely used in astronomical observations either in direct imaging use or spectroscopic mode. However, the areas of available sensors are too small for large imaging format. One possibility to obtain large detection area is to assemble mosaics of CCD, and drive them simultaneously. Parallel driving of many CCDs together rules out the possibility of individual tuning; however, such optimisation is very important, when the ultimate low light level performance is required, particularly for new, or mixed devices. In this work, a new concept is explored for an entirely novel approach, where the drive waveforms are multiplexed and interleaved. This simultaneously reduces the number of leadout connections and permits individual optimisation efficiently. The digital controller can be designed within a single EPLD (Erasable Programmable Logic Device) chip produced by a CAD software package, where most of the digital controller circuits are integrated. This method can minimise the component. count., and improve the system efficiency greatly, based on earlier works by Han et a1. (1996, 1994). The system software has an open architecture to permit convenient modification by the user, to fit their specific purposes. Some variable system control parameters can be selected by a user with a wider range of choice. The digital controller design concept allows great flexibility of system parameters by the software, specifically for the compatibility to deal with any number of mixed CCDs, and in any format, within the practical limit.

  • PDF

방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작 (Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments)

  • 차동수;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

SMC Full PACS로의 전환 및 System 구축

  • 김삼수
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.20-23
    • /
    • 1997
  • The purpose of this paper is to describe the transition of a 1,100 beds teritary hospital from 50% softcopy operation to full PACS operation. For the past 2 years, radiologists and clinicians have been using PACS to provide softcopy services to the outpatient clinics and inpatient wards of orthopedics surgery, neurosurgery and neurology as well as emergency room, surgical intensive care unit, medical intensive unit, pediatrics intensive care unit and neonatal intensive care unit. The examinations requested by these departments account for about 50% of hospital's radiological exams. In September 1996, we began the second phase of PACS implementation and installed additional workstations (102) in the remaining wards and clinics, interfaced to PACS additional imaging modalites, and increased the capacity of both the image server (256 Gbytes) and optical juke boxes (3 Tbytes). As of January 1997, we are in the final phase of moving away from conventional film system to full PACS operation.

  • PDF

Experimental Study of Two-step Phase-shifting Digital Holography based on the Calculated Intensity of a Reference Wave

  • Li, Jun;Pan, Yang Yang;Li, Jiao sheng;Li, Rong;Zheng, Tao
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.230-235
    • /
    • 2014
  • Two-step quadrature phase-shifting digital holography based on the calculated intensity of a reference wave is proposed. In the Mach-Zehnder interferometer (MZI) architecture, the method only records two quadrature-phase holograms, without reference-wave intensity or object-wave intensity measurement, to perform object recoding and reconstruction. When the reference-wave intensity is calculated from the 2D correlation coefficient (CC) method that we presented, the clear reconstruction image can be obtained by some specific algorithm. Its feasibility and validity were verified by a series of experiments with 2D objects and 3D objects. The presented method will be widely used in real-time or dynamic digital holography applications.

대칭성 공차를 갖는 교환렌즈용 줌 렌즈의 핀트 조정법과 통계적 해석 (Focus Adjustment Method with Statistical Analysis for an Interchangeable Zoom Lens with Symmetric Error Factors)

  • 류재명;조재흥;강건모;이해진;요네야마 슈지
    • 한국광학회지
    • /
    • 제22권5호
    • /
    • pp.230-238
    • /
    • 2011
  • 디지털 일안 반사식 카메라 또는 콤팩트 시스템 카메라용의 교환렌즈용 줌 광학계는 화각과 제품 사양에 따라 여러 가지 형태 가 있으므로, 하나의 AF(auto-focus)군으로만 줌 렌즈의 광각단과 망원단 2곳에서 상면이동의 보정(즉, 핀트 조정)이 불가능한 경우가 발생한다. 또한 줌 광학계의 광각단과 망원단 2곳에서의 후초점거리(back focal length, BFL)가 설정된 BFL 설계값과 일치하도록 조정하기 위해서는 적어도 2곳에서 핀트 조정을 해야 한다. 본 논문에서는 이러한 광학계에 대한 종민감도의 개념을 사용한 핀트 조정의 계산 방법에 대해 제안하고, 이 광학계에 대해 핀트 조정의 조정량 한계를 통계적 분석을 통하여 계산했다.

디지털 카메라용 줌렌즈에서 대칭성 오차요인에 의한 상면 변화의 보정과 이에 따른 불량률 예측 (Correction method for the Variation of the Image Plane Generated by Various Symmetric Error Factors of Zoom Lenses of Digital Still Cameras and Estimation of Defect Rate Due to the Correction)

  • 류재명;강건모;이해진;이혁기;조재흥
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.420-429
    • /
    • 2006
  • 곡률, 두께, 굴절률 오차와 같은 광축대칭 오차요인들 때문에 상면이 이동하는 디지털 카메라용 줌렌즈 광학계에서 보상자를 이동시켜서 상면을 고정시키는 조건을 가우스 괄호법을 이용하여 유도하였다. 그리고 줌렌즈 광학계의 일반적인 세 가지 형태(3군, 4군, 5군 줌렌즈)를 사용하여 이 조건의 타당성을 검증하였다. 이러한 줌렌즈 형태에서 각 면의 곡률, 두께, 굴절률 등을 공차 내에서 Monte Carlo 방법에 따라 임의로 변화시켰을 때, 보상자의 이동량의 분포가 정규분포를 이루는 것을 확인하였다. 그리고 이로부터 공정능력을 계산하여 보상자의 최대 이동량에서 이에 따른 불량률을 이론적으로 예측하는 방법을 제시하였다.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

반사형 디지털 홀로그래피 현미경 시스템에서의 조사면적 및 재생면적의 확대기록 (Recording and Reconstruction of large object area by using Reflection type Digital Holography Microscope System)

  • 최규환;김성규;조동현;윤선규
    • 한국광학회지
    • /
    • 제17권4호
    • /
    • pp.335-341
    • /
    • 2006
  • 마이켈슨 간섭계 시스템에 두 개의 Convex Lens를 추가함으로서 평면파 참조광을 유지 시키며, 물체에 조사되는 물체광의 조사면적을 증대시킬 수 있는 변형된 마이켈슨 간섭계를 제작하였다. 변형된 마이켈슨 간섭계를 반사형 디지털 홀로그래피 현미경 시스템(Digital Holography Microscope System)에 적용한 결과 두 개의 Convex Lens를 추가하지 않은 고전 마이켈슨 간섭계를 사용한 디지털 홀로그래피 현미경 시스템 보다 넓은 영역에 대해 물체를 기록 할 수 있으며 또한 보다 넓은 영역을 재생 할 수가 있다.